Bids Are invited for Operation And Maintenance Power House / Power Plant - Biannual Maintenance Contract For All Maintenance Activities In Electrical Maintenance Department At Rgppl- Site(2026-28) - Preventive Maintenance Of All Type Ht-Motors. , Ir-Checking Of All Type Ht-Motors. , Trouble-Shooting And Maintenance Of All Type Ht-Motors. , No-Load/Load Trial Of All Type Ht-Motors/Transformers. , Re-Greasing And Lube Oil Top-Up Of Both Side Bearings Of All Type Ht-Motors. , Lube Oil S Ling Of One Side Bearing Of All Type Ht-Motors. , Removal/Re-Fixing Of All Cable Terminals Of All Type Ht-Motors. , Maintenance And Repairing Of Power Cable Terminal Box/Heat Exchanger (Cooler)/Cooling Fan/Fan Enclos , Removal Of All Type Ht-Motors From Foundation. , Re-Fixing And Commissioning Of All Type Ht-Motors On Foundation. , Removal/Re-Fixing Of Heat Exchanger (Cooler)/Cooling Fan With Enclosure/Power Cable Terminal Box Of , De/Nde-Side Bearing/Water Cooler Replacement Of All Type Ht-Motors. , Preventive Maintenance Of Vacuum Circuit Breaker/Air Break Switch Including Complete Cubicle Section , Preventive Maintenance Of One Horizontal Bus-Bar Section Of Ht-Switchgears Except Vcbs , Trouble-Shooting And Maintenance Of All Type Ht-Switchgears. , Replacement Of Vcb/Air Break Switch/C.T./P.T. Of Ht-Switchgearsincluding Shifting Within Plant , Servicing Of Vacuum Circuit Breaker/Air Break Switch Including Complete Cubicle Section/Complete T.B , Preventive Maintenance Of All Type Lt-Motors Upto 30 Kw Rating. , Preventive Maintenance Of All Type Lt-Motors Above 30 Kw To 100 Kw Rating. , Preventive Maintenance Of All Type Lt-Motors Above 100 Kw To 200 Kw Rating. , Ir-Checking Of All Type Lt-Motors. , Trouble-Shooting And Maintenance Of All Type Lt-Motors. , No-Load/Load Trial Of All Type Lt-Motors. , Re-Greasing/Lube Oil Top-Up Of Both Side Bearings Of All Type Lt-Motors Upto 30 Kw Rating. , Re-Greasing/Lube Oil Top-Up Of Both Side Bearings Of All Type Lt-Motorsabove 30Kw To 200Kw Rating. , Removal/Re-Fixing Of All Cable Terminals Of All Type Lt-Motors Upto 30 Kw Rating. , Removal/Re-Fixing Of All Cable Terminals Of All Type Lt-Motors Above 30 Kw To 200 Kw Rating. , Maintenance/Replacement Of Cooling Fan/Fan Cover/Power Cable Terminal Box Of All Type Lt-Motors Upt , Maintenance/Replacement Of Cooling Fan/Fan Cover/Power Cable Terminal Box Of All Type Lt-Motors Abo , Removing Of All Type Lt-Motors From Foundation And Transporting From Location To Anywhere Within The , Removing Of All Type Lt-Motors From Foundation And Transporting From Location To Anywhere Within The , Removing Of All Type Lt-Motors From Foundation And Transporting From Location To Anywhere Within The , Re-Fixing And Commissioning Of All Type Lt-Motors On Foundation Including Transportation From Anywh , Re-Fixing And Commissioning Of Lt-Motors On Foundation Above 30 Kw To100 Kw Rating. , Re-Fixing And Commissioning Of Lt-Motors On Foundationabove 100 Kw To200 Kw Rating. , Overhauling Of All Type Horizontal/Vertical Lt-Motors Upto 3.0 Kw Rating. , Overhauling Of All Type Horizontal/Vertical Lt-Motors Above 3.0 Kw To 10 Kw Rating. , Overhauling Of All Type Horizontal/Vertical Lt-Motors Above 10 Kw To 50 Kw Rating. , Overhauling Of All Type Horizontal/Vertical Lt-Motors Above 50 Kw To 100 Kw Rating. , Overhauling Of All Type Horizontal/Vertical Lt-Motors Above 100 Kw To 200 Kw Rating. , Preventive Maintenance Of One Starter Module Including Complete Cubicle Section Of Lt-Mcc. , Preventive Maintenance Of Air Circuit Breaker Including Complete Cubicle Section Of Lt-Switchgears. , Pm Of One Bus-Bar Section Of Lt-Switchgears/Mcc Except Acbs/Starter Modules , Trouble-Shooting And Maintenance Of Lt-Switchgears/Mcc. , Replacement Of One Complete Starter Module Of Lt-Mcc. , Replacement Of Acb Of Lt-Switchgear Including Loading Unloading & Shifting Within The Plant Area. , Servicing Of One Complete Starter Module Of Lt-Mcc. , Servicing Of Air Circuit Breaker Including Complete Cubicle Section Of Lt-Switchgears. , New Electrical Panel Designing Assemblingcontrol Wiring Etc Of Panel Upto 1.0 Mtr X 2.0 Mtrs. , Electrical Insulating Mat Replacement Thickness: 3.0Mm Width: 1.0 Mtr. , Reading Measurement (Current Voltage Power Etc) Of Any Equipment Of Switchgear/Motor/Mcc Etc. , Replacement/New Electrical Panel Installation & Commissioning Etc.Of Size Upto 1.0 Mtr X 2.0 Mtrs. , Preventive Maintenance Of All Type Transformers Upto 4.0 Mva Rating Including All Accessories. , Preventive Maint. Of All Type Transformers Above 4Mva To 40 Mva Rating Including All Accessories. , Preventive Maint. Of All Type Transformers Above 40Mva To 400 Mva Rating Including All Accessories. , Trouble-Shooting And Maintenance Of All Type Transformers Upto 400 Mva Rating. , Removal/Re-Fixing Of Hv Lv & Neutral Connections Of All Type Transformers Upto 4.0 Mva Rating. , Removal/Re-Fixing Of Hv Lv & Neutral Connections Of All Type Transformers Above 4.0 Mva To 40 Mva R , Removal/Re-Fixing Of Hvlv & Neutral Connections Of All Type Transformers Above 40Mva To 400Mva Rati , Replacement Of Silicagel/Silicagel Breather/Surge Counter/Regeneration Of Silicagel Etc Of All Type , Protections And Interlocks Checking Of All Type Transformer Upto 40 Mva Rating. , Protections And Interlocks Checking Of All Type Transformer Above 40 Mva To 400 Mva Rating. , Testing Arrangement Including Assistance Required For Testing Of All Type Transformer Upto 4.0 Mva R , Testing Arrangement Including Assistance Required For Testing Of All Type Transformer Above 4.0 Mva , Testing Arrangement Including Assistance Required For Testing Of All Type Transformer Above 40 Mva T , Routine-Checking Including Thermography Of Gsu Uat & Sst Transformers. , Shifting Of Filter Machine/Oil Storage Tank/Bushing Stand/Transformer Bushing/L.A./Transformer Coole , Maintenance And Repairing Of Oil Filtration Machine/Oil Storage Tank/Platform Truck. , Transformer Oil S Le Collections Including Packing/Bdv-Testing In Em-Lab. , Transportation Of Transformer Oil S Le Bottles From Rgppl-Site To R&D (Netra)-Noida. , Transportation Of Transformer Oil S Le Bottles From R&D (Netra)-Noida To Rgppl-Site. , Transportation Of Testing Instrument/Oil S Le/Other Material Up To 25Kg Weight From Rgppl-Site To , Transportation Of Testing Instrument/Oil S Le/Other Material Up To 25Kg Weight From Mumbai/Pune/Ko , Oil Filtration Of All Type Transformer Upto 4.0 Mva Rating. , Oil Filtration Of All Type Transformer Above 4.0 Mva To 40 Mva Rating. , Oil Filtration Of All Type Transformer Above 40 Mva To 400 Mva Rating. , Oil Top-Up Including Filtration (Upto 2.0 Kl Qty) Of All Type Transformer. , Dismantling And Removing Of Distribution Transformers Upto 2.0 Mva Rating/Transformer Ngr Anywhere W , Installation And Commissioning Of Distribution Transformers Upto 2.0 Mva Rating/Transformer Ngr Anyw , Overhauling Of Distribution Transformers Upto 2.0 Mva Rating. , Preventive Maintenance Of All 3 Poles Of Circuit Breaker/Isolator With Earth-Switch Of Switchyard. , Preventive Maintenance Of All Three Poles Of C.T./ C.V.T./L.A./Bushings/ Wavetrap Of Switchyard & Tr , Preventive Maintenance Of All Type Marshalling Box/Control Panels/Air Compressors Of Switchyard. , Trouble-Shooting And Maintenance Of Control Circuit And Any Equipments Of Switchyard. , Routine Checking Including Thermography Of All Equipments Of Switchyard. , Sf6/N2 Gas Topping-Up In One Circuit Breaker Pole Of Switchyard & Transformer. , Alignment Of All Three Poles Isolator Of Switchyard. , Alignment Of All Three Poles Earthswitch Of Switchyard. , Removing & Dismantling Of One Pole Of Cb(Sf6)/Isolator With Earth Switch/Wavetrap/Ct/Cvt/La/Bushing , Refixing/New Erection&Commissioning Of Cb(Sf6) One Pole/ Isolator With Es/Wavetrap/Ct/Cvt/La/Bushing , Testing Arrangementassistance For Testing Of All 3 Poles Of Cb/Ct/Cvt/La/Isolator/Es/Wavetrap Etc. , Maintenance Of All Type Of Earth Pit , Earth Resistance Measurement Of All Electrical Equipments Of Plant & Bop Area. , Assistance/Support Service Required During Unit Start-Up/Shut-Down. , Replacement & Commissioning Of Air Compressor Assembly Of Switchyard Circuit Breaker. , Overhauling Of All Type Pneumatic Drive Of 400Kv Switchyard Circuit Breaker. , Overhauling Of One Pole Of All Type Isolator With Earth Switch Of Switchyard. , Overhauling Complete One Pole Of All Type Circuit Breaker Of Switchyard. , Preventive Maintenance Of Generator Upto 360 Mva Rating. , Pm Of All Three Phase Complete Busduct From Generator To Transformer Upto 15.75 Kv Rating. , Preventive Maintenance Of Bac Cubicle Compartments (Lci Excitation & Pt Complete Cubicles). , Pm Of Complete Cubicle Compartments Of Ppt-Transformer/89 Ss-Air Break Switch/Dc-Link Reactor Etc. , Ir-Checking Of Generator Busduct Lci Excitation & Accessories. , Trouble-Shooting And Maintenance Of Control Circuit And Any Equipment Generator And Accessories. , Routine Checking Of Lci Excitation Ppt-Fan & Cooling System Of Bac-Compartment. , Generator Line-Up For Air/Co2/Hydrogen Filling. , Replacement Of Carbon Brush/Brush Holder/Hydrogen Regulator Etc. , Removal Of Flexible Links Star Point Bus-Bar And Ngr Connections Of Generator. , Testing Arrangement Including Assistance Required For Testing Of Generator Busduct & Accessories. , Replacement Of Generator Neutral Connection Protection Ct/La/Flexible C Links/Ngr/Phe (Lci) Etc. , Testing Arrangement Including Assistance Required During Testing & Calibration , Trouble-Shooting And Maintenance Of Relay/Cards/Meters/Transducers/Abt-System/Ct/Pt Etc. , Replacement And Modification Of Relay/Cards/Meters/Transducers/Abt-System/Ct/Pt Etc. , Pm Of Lead Acid Type Complete Battery Bank (Rating From 125 Volts To 250 Volts/300 Ah To 1700 Ah). , Preventive Maintenance Of All Type Battery Charger/Distribuation Panel (Dc/Ac). , Trouble-Shooting And Maintenance Of Battery Charger/Battery Bank/Distribution Panel (Dc/Ac). , Routine Checking Of All Type Battery Banks And Chargers. , Lead Acid Battery Bank Replacementcommissioning &Testingrating 125 V To250 V/300 Ah To1700 Ah. , One Cell Replacementcommissioning & Testing Of La Battery Bank (125 V To250 V /300 Ah To 1700 Ah) , Replacementcommissioning & Testing Of Battery Charger Incl. Loading Unloading & Transportation. , Discharge Test Of All Type Complete Battery Bank Of Rating Upto 250 Volts/1700 Ah). , Shifting Of Scrap Battery/Acid Can Min.10 Nos Acid Can Of 40 Ltrs/20 Nos Vrla//Alkaline Batteries , Assistance/Support Services Required During Inspection Testing And Maintenance Of Equipments , Pm Of Complete Electrical System Of Eot/Gantry Crane Capacity Rating Upto 100 Tons. , Preventive Maintenance Of Complete Electric Hoists Unit Capacity Rating 2X35 Tons. , Troubleshooting And Maint. Of Electrical System Of Eot/Gantry Crane Electric Hoists & Stack-Lift. , Maintenance & Repairing/Replacement Of Control Panel/Resistance Box/Control Transformer/Motor Etc. , Arrangement Including Assistance Required For Load Testing Of Electric Hoists Unit (35 Tons) , Trouble-Shooting And Maintenance Of Overhead Distribution Lines. , Replacement Of All Type Insulators/Cl S/L.A. Etc Of Overhead Distribution Lines. , Replacement/New Installation Of Complete Kiosk Panel/G.O.D/Fuse Assembly Etc Of Oh Lines. , Removing/Laying Of Conductor Earth Wire Guard Wire Etc Of Overhead Distribution Lines. , Temporary Laying/Removing Of All Type Cables Including Shifting Cable Size Upto 50 Sq.Mm. , Temporary Laying/Removing Of All Type Cables Including Shifting Cable Size Above 50 To 120 Sq.Mm. , Permanent Laying Of Cables On Cable Tray Wall & Structure Etc.Cable Size Upto 50 Sq.Mm. , Permanent Laying Of Cables On Cable Tray Wall & Structure Etc.Cable Size Above 50 To 120 Sq.Mm. , Permanent Laying Of Single Core Cables On Cable Traywall & Structure Etc.Size > 120 To <240 Sqmm , Permanent Laying Of Single Core Cables On Cable Tray Wall & Structure Etc.Cable Size > 240 Sq.Mm. , Permanent Laying Of 3/4 Cores Cables On Cable Tray Wall & Structure Etc.Size > 120 To <240 Sqmm , Permanent Laying Of 3/4 Cores Cables On Cable Tray Wall & Structure Etc. Size Above 240 Sqmm , One End Lugging/Jointing Of All Type Lt-Cables (All Cores) Cable Size Upto 50 Sq.Mm. , One End Lugging/Jointing Of All Type Lt-Cables (All Cores) Cable Size Above 50 To 120 Sq.Mm. , One End Lugging/Jointing Of All Type Lt-Cables (All Cores) Cable Size Above 120 Sq.Mm. , Single Core Heat Shrinkable Cables Termination/Through Jointing Of Cables Size Upto 120 Sq.Mm. , Single Core Heat Shrinkable Cables Termination/Through Jointing Of Cablessize Above 120 To240 Sqmm , Single Core Heat Shrinkable Cables Termination/Straight Through Jointing Of Cables Above 240 Sqmm , Outer Insulation Repairing Of Cables From Heat Shrinkable Tubing/Sleeves (1Mtr Length). , Laying/Removing/Repairing Of Cable Tray( Above 0.5 Ft X 2.0 Ft) /Conduit Pipe(Above Dia:3 Inch) , Laying/Removing/Repairing Of Cable Tray( Upto 0.5 Ft X 2.0 Ft)/Conduit Pipe(Upto 3.0 Inch Dia.) , Earthing Strip Laying Or Removing Including Drilling Welding Jointing Cutting Etc. , Preventive Maintenance Of All Type Lighting Transformers/Lighting Distribution Panels. , Maintenance/Replacement Of Industrial Pole Lighting Fixture Upto 30 Feets Height , Maintenance/Replacement Of All Type Industrial Lighting Fixture. , Maintenance/Replacement/Servicing Of All Type Cooling Fans/Exhaust Fan Etc. , Maintenance/Replacement Of High Mast/Hrsg-Stacks Aviation Lighting Fixture. , Trouble-Shooting And Maintenance Of All Type Lighting/Cooling Fans/Lighting Transformers Etc. , Replacement/New Erection & Commissioning Of Lighting Pole With All Accessoriesheight Upto 15 Fts. , Replacement/New Erection & Commissioning Of Lighting Pole With Pole Height Above 15 To 30 Feets. , Maintenance/Replacement Of Lighting Pole Junction Box/Sdfu/Dol-Starter Etc. , Maintenance/Replacement Of All Type Mcb/Rccb/Elcb/Timer Etc. , Maintenance/Replacement Of Domestic Lighting System/Electrical Appliances , Revival Of One Room Complete Lighting System Of Any Buildings In Plant & Bop Area. , Arrangement Of Temporary Lights/Cooling Fans/Cable Connections Etc. , Overhauling Of Ceiling Fans/Table Fans/Exhaust Fans/Geyser Etc. , Preventive Maintenance Of Electrical System Of All Type Skids. , Ir-Checking Of All Type Skids. , Trouble-Shooting And Maintenance Of Electrical System Of All Type Skids. , Installation & Commissioning Of Any Type Complete Skid Anywhere Within The Plant Area. , Preventive Maintenance Of Electrical System Of Edg/Fire Pump. , Trouble-Shooting And Maintenance Of Electrical System Of Edg/Fire Pump. , Replacement Of Dc-Starter/Control Module Of Edg/Fire Pump. , New Fabrication And Erection Works Of Mild Steel Supporting Structure Or Frame At Rgppl-Site. , Providing Welder On Day Basis As Per Work Specifications. , Erection And Dismantling Of Scaffolding As Per Work Specifications. , Tarpaulin And Polythene Sheet Covering Before Monsoon Season/Removing After Monsoon Season. , Shifting Of Any Material From One Location To Other Location In The Plant Area Upto 250 Kg Weight. , Shifting Of Any Material From One Location To Other Location In The Plant Area >250 Kg To < 500Kg , Shifting Of Any Material From One Location To Other Location In The Plant Area >500 Kg To <750 Kg , Shifting Of Any Material From One Location To Other Location In The Plant Area >750 Kg To <1500 Kg , Shifting/Relocation Of Any Material From Inside The Power Block From Eot Cranes Above 1.0 Ton , Oil Drum (210 Ltr)Shifting From One Location To Other Location In The Plant Area. , Shift Electrical Maintenance Activities In Power Block & Bop Area As Per Scope Of Work , Operation Service Of Mobile Hydraulic Industrial Vehicles/Cranes As Per Scope Of Work. , Providing Skilled Workers On Day Basis As Per Scope Of Work. , Store Keeper In Electrical Lab/Store As Per Scope Of Work. , Providing Semiskilled Workers On Day Basis As Per Scope Of Work. , Shift Electrical Maintenance Activities In Township Area (Three Shifts Per Day) As Per Scope Of Work
|