Oxygen Sensor Galvanic Type Oxygen Sensor Is Designed To Determine The Actual Oxygen Concentration In The Inhaled Mixture. Measuring Range 0% To 100% O2. Accuracy And Repeatability < 1% O2 Volume When Calibrated To 100% Oxygen. Linearization Error < 3% Relative. Response Time < 12 Seconds To 90% Of Final Value. Crosstalk. Meets The Requirements Of Iso 80601-2-55. Influence Of Humidity -0.03% Relative In %Rh At 25°C. Impact Of Mechanical Shock < 1% Relative After Falling From A Height Of 1 Meter. Temperature Compensation Built-In Ntc Compensation. Long Term Yield Bias < 1% Oxygen Volume Per Month Typically < -15% Relative Over Service Life. Storage Temperature: -20°C To +50°C. Lasts For Life. Maximum Storage Life From +5°C To +15°C. Warm-Up Time < 30 Minutes After Sensor Replacement. Rated Sensor Life ≥ 1,000,000% Volume Hours Oxygen. All Specifications Apply To Standard Conditions: 1013 Hpa; 25°C Dry, Ambient Air. Must Be Agreed With The Customer.+7 707 783 1177 Gost 31513-2012 Intensive Care Unit Maternity Hospital, Set Of Filters For The Hamilton T1 Device Set Of 5 Filters. The Turbine Dust Filter Is Designed To Pre-Clean The Intake Air From The Environment. The Cooling Fan Filter Provides Protection From Dust To The Internal Components And Electronic Components Of The Device. Must Be Agreed With The Customer. +7 707 783 1177 Intensive Care Unit Maternity Hospital, The Expiratory Valve Membrane Is Designed For Use As Part Of The Reusable Exhalation Valve Of The Hamilton T1 Ventilator And Ensures Correct Separation Of The Inspiratory And Expiratory Phases, As Well As Maintaining The Set Pressure Level (Peep). The Product Must Be Fully Compatible With The Original Hamilton T1 Expiratory Valve And Not Require Additional Adapters During Installation. The Membrane Is Made Of Medical Elastomer Material, Providing High Tightness, Resistance To Deformation And Stable Performance During Repeated Use. Must Withstand Sterilization Cycles (Including Autoclaving) Without Loss Of Functionality. Provides Low Flow Resistance And Precise Operation Of The Valve Mechanism. Delivery Is Carried Out In A Package Of 5 Pieces. Products Must Be New, Without Traces Of Use, With A Confirmed Expiration Date. Membranes Must Comply With International Quality And Safety Standards (Iso, Ce If Available) And Be Approved For Use In The Territory Of The Republic Of Kazakhstan Or The Eaeu. Must Be Agreed With The Customer. +7 707 783 1177 Intensive Care Unit Maternity Hospital, Exhalation Valve (Expiratory Valve) Reusable For Hamilton T1 Ventilator Purpose The Expiratory Valve Is Designed To: Regulate The Flow Of Exhaled Gas, Maintain A Given Level Of Positive End-Expiratory Pressure (Peep), Separate The Respiratory Phases (Inhalation/Exhalation), Protect The Internal Components Of The Device From Contact With The Exhaled Gas Of The Patient Compatibility Full Compatibility With The Hamilton T1 Ventilator, Compatibility With Systems: Hamilton C1 / T1 / Mr1, Support For Working With Patients: Neonatal (Depending On From Version - Neonatal) Product Type Type: Reusable (Reusable / Autoclavable) Possibility Of Sterilization: Autoclaving Design: Dismountable Must Be Agreed With The Customer. +7 707 783 1177 Intensive Care Unit Maternity Hospital, Hepa Filter For Hamilton T1 Device. Hepa Filter For Hamilton /T1/C1 Devices Hepa Filter Intake Air Filter. The Filter Is Designed For Fine Purification Of Air Taken From The Environment. It Consists Of A Special Material, The Fibers Of Which Are Arranged In Such A Way As To Trap Pollutant Particles From The Air. Hepa Filters Purify The Air From 99.95% To 99.995% Of Particles. Must Be Agreed With The Customer. +7 707 783 1177 Intensive Care Unit Maternity Hospital
Contact Information
Contact Person
Биналиева Олеся Васильевна
Address
195220100, none, КАЗАХСТАН, г. Каскелен, ул. ЖАНГОЗИН, д. 14, оф.
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 113461556
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.