Hydrogen Peroxide, Solution For External Use, 6%, 400Ml, // Medical Cotton Gauze, Bleached, In Rolls 1000Mx90cm. Non-Sterile, Hygroscopic, Width 90+-1.5 Cm, With Plain Weave And Surface Density Of At Least 36 G/M². The Permissible Deviation In Surface Density Must Be No Less Than Minus 5%, The Number Of Threads Per 10 Cm For The Warp Is 121-2, For The Weft 71-2. The Breaking Load Of A Strip Of Fabric Measuring 50*200 Mm, N (Kgf), Must Be No Less Than: For The Warp 78 (8.0) For Duck 34 (3.5). Linear Density Of Yarn, Texture: According To Warp No Less Than 20.0, Weft 20.0. Wetability No More Than 10 Seconds. The Gauze Should Be Made From Cotton Yarn. The Gauze Must Be Rolled Into Rolls In A Sleeve The Full Width Exactly Without Distortions And Drooping Edges, Supplied In Rolls In A Sleeve Of 1000 Meters. The Presence Of Defects Of The 1St And 2Nd Groups In The Roll Is Not Allowed. The Gauze Must Be Resistant To Steam Sterilization. Gost 9412-93. Medical Gauze., Mechanical Tonometer Ua-200 With Separate Stethophonendoscope, Cuff 22-32 Cm Mechanical Tonometer With Rappaport Stethoscope And Standard Cuff 22-32 Cm • Standard Cuff 22–32 Cm • Rappaport Stethoscope • Anti-Dust Mesh On The Blower And Fitting • Metal Pressure Gauge With Calibration Capability • Continuously Adjustable Air Release • Includes Storage Case And Set Of Accessories For The Stethoscope • Warranty For The Main Unit (Pressure Gauge) - 3 Years Technical Specifications: • Measurement Range: 20–280 Mmhg. Art. • Measurement Error: ±3 Mm Hg. Art. • Method Of Inflating The Cuff: Manually, Using An Inflator • Cuff Size: 22-32 Cm. • Pressure Gauge Size, Mm, ±10% 88 X 33.5 Mm. • Pressure Gauge Diameter, Mm, ±10% 51 • Pressure Gauge Mass, G, ±10% 105., Ethyl Alcohol 96% Rectified For Medical Use From Edible Raw Material Wheat 96.3% With The Obligatory Provision Of A Certificate Of Conformity. Gost 5962-2013 Grade “Alpha”. Ethyl Alcohol., // Alcohol Wipe For Injections 65X30 Mm (Impregnated With 70% Ethyl Alcohol), Disposable. Pack Of 100 Pcs. St Rk St Rk 2255-2021 Disposable Wet Wipes For Sanitary And Hygienic Purposes (Alcohol Wipe For Injection), Express Test Strip For Alcohol (Saliva) Alc - S11 No. 50 Pieces. The Rapid Alcohol Test Strip (Saliva) Is A Rapid, Highly Sensitive Method Of Detecting The Presence Of Alcohol In Saliva And Approximating A Relative Blood Alcohol Concentration (Bac) Of 0.02% (Equivalent To 0.2‰) Or Higher. This Test Provides Only A Preliminary Viewing., Automatic Blood Pressure Monitor Ua-1100 With Adapter With Intelligent Control And Network Adapter. • Measurement Range: 20–280 Mmhg. Art. (Pressure) 40–200 Beats/Min (Pulse Rate) • Measurement Error: Pressure ±3 Mm Hg. Art., Pulse ±5% • Cuff Inflation Method: Automatic. • Power Source: 4 Aa Batteries, Ac Adapter. • Cuff Size: 23-37 Cm. • Device Size, Mm, ±10% 140 X 105 X 61. • Weight Without El. Nutrition, G, ±10% 265.
|