|
1.1 - Supply And Installation Of Workplate With Galvanized Sheet And Wooden Structure. Af032022ps20260401, 1.2 - Regularization And Compaction Of Predominantly Clayey Soil Subgrade, For Pavement Construction Works. Af09202420260401, 1.3 - Manual Removal Of Precast Concrete Curb Guide, With Reuse, Including Removal And Stacking, Excluding Transportation And Removal Of Non-Reusable Removed Material20260401, 2.1 - Installation Of Straight Curb Guide, Made Of Concrete Pre-Fabricated, Dimensions 80X08x08x25 Cm Length X Lower Base X Upper Base X Height. Af01202420260401, 2.2 - Execution Of Flooring On Interlocking Floor, With Natural Color Rectangular Block Of 20 X 10 Cm, Thickness 6 Cm. Af10202220260401, 2.3 - Execution Of Flooring On An Interlocking Floor, With A Colored Rectangular Block Of 20 X 10 Cm, Thickness 8 Cm. Af10202220260401, 2.4 - Execution Of Sidewalk Or Concrete Floor With Cast-In-Place Concrete, Made On Site, Conventional Finish, Thickness 8 Cm, Reinforced. Af08202220260401, 2.5 - Floor Painting With Acrylic Paint, Manual Application, 2 Coats, Including Primer. Af05202120260401, 2.6 - Ramp For Disabled Access, In Simple Concrete Fck 25 Mpa, Straightened, With Indicative Painting, 02 Coats20260401, 2.7 - Urban Concrete Gutter Scu, Type 2, With Fck 15 Mpa, 50Cm Wide With Slope 15%, Esp. 7Cm, Der-Mg Standard, Exclusive Curb, Including Excavation, Piling And Transport With Removal Of Excavated Material In Bucket20260401, 2.8 - Vacancy Demarcation Painting With Acrylic Paint, And 10 Cm, Manual Application. Af05202120260401, 3.1 - Corrugated Flexible Conduit, Hdpe, Dn 50 1 12, For Underground Electricity Distribution Network - Supply And Installation. Af12202120260401, 3.2 - Insulated Flexible Copper Cable, 2.5 Mm², Anti-Flame 450750 V, For Terminal Circuits - Supply And Installation. Af03202320260401, 3.3 - Photoelectric Relay For 1000 W External Lighting Control - Supply And Installation. Af02202520260401, 3.4 - Manual Trench Excavation. Af09202420260401, 3.5 - Manual Trench Backfilling, With Vibrating Plate. Af08202320260401, 3.6 - Din Type Bipolar Circuit Breaker, 25A Rated Current - Supply And Installation. Af07202520260401, 3.7 - Double Curved Continuous Tapered Steel Post, Flanged, H9m - Supply And Installation. Af04202520260401, 3.8 - Led Luminaire For Public Lighting, From 98 W To 137 W, Housing In Aluminum Or Stainless Steel20260401, 4.1 - Bench In Apparent Concrete, Type-2, See-Mg Standard, Backless, Polished With Varnish Finish, Esp. 5Cm, Length 150Cm, Width 40Cm, Height 45Cm, Including Cut In The Floor For Fixing With Non-Structural Concrete, Prepared On Site With A Concrete Mixer, With Fck 15 Mpa20260401, 4.2 - Flowering Shrub Seedling, Clusiagardeniamoreia Branca Azaleia Or Equivalent From The Region, H 050 To 700 Cm20260401, 4.3 - Planting A Shrub Or Hedge. Af07202420260401, 4.4 - Installation Of A Double Metal Trash Can, Capacity Of 60 L, In Carbon Steel Tube And Steel Sheet Baskets With Electrostatic Painting, On An Existing Concrete Floor. Af11202120260401, 5.1 - Permanent Cleaning Of The Site - 01 Employee X 4 Hours Daily20260401
|