Bids Are Invited For The Purpose Of This Notice Is To Acquire Veterinary Inputs, Materials And Medical Equip ... in Brazil
Tender Notice
TenderID
112852553
Tender Brief
Bids Are Invited For The Purpose Of This Notice Is To Acquire Veterinary Inputs, Materials And Medical Equipment For The Modernization And Improvement Of The Technical Assistance Infrastructure Of The Uniube Veterinary Hospital, With A Focus On The Care, Treatment And Rehabilitation Of Wild Animals Rescued By The Environmental Military Police And The Military Fire Department Of Minas Gerais, From The Municipality Of Uberaba And The Entire Southern Region Of The Triângulo Mineiro.
Capnography Module For Veterinary Use - Sidestream 1. General Features.-Sidestream Type Capnography Module, With Multichannel Infrared Detector -Operating Principle Based On Non-Dispersive Infrared Gas Analyzer (Ndir).-Compact Design, Suitable For Integration Into Veterinary Multiparametric Monitors.-Suitable For Use In Inhalation Anesthesia And Intensive Monitoring-Performs Continuous Measurement Of The Concentration Of Carbon Dioxide (Co2) And Respiratory Rate.-It Has An Exhaust Port For Exhausting The Analyzed Gases.-No Need For Periodic Calibration, Ensuring Practicality And Stability In Measurements.2. Technical Specifications-Sensor Type: Sidestream, Non-Dispersive Gas Infrared (Ndir)-Co2 Measurement Range: 0 To 19.7% (150 Mmhg Or 0 To 20 Kpa)-C02 Reading Resolution: 0.1Mmhg.-C02 Measurement Accuracy: -0-40 Mmhg: 2 Mmhg-41-70 Mmhg: 5% Of Reading-71-100 Mmhg 8% Of Reading-101-150 Mmhg10% Of Reading -Breathing Rate: 2 To 150 Bpm.-Respiratory Rate Accuracy 1% Or 1 Bpm-Operating Temperature:5°C To 50°C.-Operating Humidity:10% At 90% -Storage Temperature:40°C To 70°C.-Storage Humidity: <90%.-Power Supply: 5 V 5% (Maximum Ripple 200 M V Pp)-Energy Consumption:-120 Ma (In Operation).-Calibration: Does Not Require Periodic Calibration.-Exhaust Port: Present In The Module.3.Dimensions E Weight - Compact Dimensions, Allowing Attachment To Monitors And Anesthesia Equipment - Reduced Weight, Ideal For Use In Surgical And Veterinary Intensive Care Environments.4. Included Items.-1 Sidestream Capnography Module.-Set Of Disposable Sampling Lines.-1 User Manual.-Cable W Compatible Connectors For Integration With Veterinary Multiparametric Monitors., Capnography Module For Veterinary Use? Mainstream Technical Characteristics: 1. General Characteristics - Mainstream Type Capnography Module, Suitable For Veterinary Use. - Operating Principle Based On Non-Dispersive Infrared (Ndir) Technology, With Double Wavelength. - System Without Moving Parts, Ensuring Greater Durability And Reading Stability. - Displays Capnogram In Less Than 4 Seconds At 25°C, Achieving Full Specifications In Up To 2 Minutes. - Robust Design, Ideal For Use In Anesthesia And Intensive Monitoring In Veterinary Patients. - Product Compatible With Veterinary Multiparametric Monitors. - Comes With Connector Filter For Interface With The Respiratory Circuit. - Does Not Require Routine Calibration. 2. Technical Specifications - Sampling Mode? Mainstrea - Operating Principle - Non-Dispersive Infrared, Dual Wavelength, No Moving Parts. - Initiation Time - Capnogram Displayed In Less Than 4 Seconds (25°C) And Complete Performance In Up To 2 Minutes. - Co2 Measuring Range - 0 To 114 Mmhg - 0 To 15% - 0 To 15.2 Kpa - Co2 Response Time - Less Than 60 Ms - Granularity Of ?O2 - - 0.2 Mmhg (0-59 Mmhg) - 0.5 Mmhg (60?114 Mmhg) - Accuracy Co2 - - 0-40 Mmhg - ±2 Mmhg - 41-70 Mmhg -±5% Of Reading -71-100 Mmhg -±8% Of Reading - 101-114 Mmhg-±10% Of Reading - Above 80 Breaths/Minute - ±12% Of Reading. - Note: Gas Temperature 25°C. - Co2 Stability - Short Term Deviation - Up To 1 Mmhg In 3 Hours. - Long Term Deviation - Accuracy Specifications Maintained For Up To 6 Hours. - Noise - Rms? 0.5 Mmhg At 5% Co2. - Sampling Rate - 100 Hz - Breath Rate Range - 2 To 150 Respi
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 112852553
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.