Medical Equipments – Spect-Ct -Laitteisto, Soite. The Object Of The Acquisition Is The Combined Molecular Imaging Device Spect-Tt (Gamma Camera And Computed Tomography System) To Be Acquired For Use By The Isotope Unit Of The X-Ray Department Of Central Ostrobothnia (Soite) (Room No. 1.427/G). The Acquired Equipment Will Be Used For Gamma Scans, Spect-Ct Scans And Ct Scans. The Equipment Will Function As A Backup Device For The 24/7 Ct Imaging Device Of The On-Call Central Hospital, Enabling And Ensuring Uninterrupted On-Call Imaging Even During Unforeseen And Anticipated Outages Of The Ct Imaging Device, As Well As During Downtime Caused By The Installation Required For The Impending Renewal Of The Ct Imaging Device. The Object Of The Acquisition Is A Functional Set For The Most Common Isotope Imaging And Spect-Tt Fusion Imaging. In Addition To The Usual Diagnostic Ct Examinations, The Functional Entity Must Also Enable The Imaging Of Ct Examinations Required For Emergency Imaging (E.G. Ct Perfusion Of The Brain, Ecg-Synchronized Ct Imaging Of Blood Vessels). The Imaging Equipment Must Be Suitable (Sensitivity, Spatial Resolution) For Gamma Imaging Of The Skeleton, Kidney Function, Heart Perfusion, Cardiac Rectification, Lung Perfusion And Ventilation, Sentinel Lymph Node, Parathyroid Gland, Thyroid Metastases And Brain Dopamine Re-Transporter Proteins. We Emphasize Features That Reduce The Patients Radiation Dose And Improve The Patients Image Quality, Such As Dose Modulation (Ct Scans) And Iterative Reconstruction (Ct And Spect Scans) As Well As Features Of Correction Programs For Scattering, Metal Artifacts, Etc. We Expect Versatile Image Analysis Software From The Device. We Appreciate The Users Ability To Flexibly Modify Imaging Parameters And Perform Image Calculation (Reconstructions) Both On The Control Workstation Of The Imaging Device And With Different Vendor Software (E.G. Hermes Medical Solutions). We Appreciate The Usability Features Of The Device, As Well As The Ergonomics And Suitability For The Purposes Required By A Central Hospital On Duty Around The Clock. Usability In Positioning The Patient On The Device So That The Entire Area Of Interest Can Be Imaged Even In Anatomically Challenging Patients Is An Important Feature Influencing The Choice Of The Device. The Flexible Layout Of Pediatric Patients And Patients Being Photographed Under Anesthesia Is Also A Feature To Consider When Choosing. In Terms Of Usability, We Prioritize The Degree Of Automaticity Of Changing Collimators And The Functionality Of Routinely Performed Quality Assurances In Terms Of Staff Ergonomics And Working Time. We Also Expect Versatile Commissioning Training And A Reliable, Quick-Response Maintenance And Spare Parts Service.
Contact Information
Address
Puutarhakatu 6
Contact No.
+358 444188847
Email
ville.laakso@sansia.fi
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 112010832
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.