|
Tender for Dismantling Of Wall And Ceiling Boards/Pvc Panelling (Fiber , Pulp, Insulation Etc, ) Or Insulation Boards/Slabs/Blankets, Any Thickness Including Cover Fillet Complete All As Specified And Directed. , S&F For Powder Coated Aluminium Anodised Snap Gird System Of Grid Size 600X600 Mm Fixed To Walls With Raw Plugs And Screws And Hang To Roof Members With 2 Mm Dia Gi Wire Comprising Of The Main Tee 28X24x3 Mm Thick, Cross Tee 28X24x3 Mm Thick Wall Angle 24X24x3mm Thick Sections, Complete All As Specified And Directed. , S&F 4Mm Thick Everest Designer Ceiling (E-Boards Classic) Board/Tile For Insulation And Accoustic Purpose, 595 X 595 Mm Size Fixed With Staples On Gi/Aluminium Snap Grid As In Ceiling With And Including Dusting Of Surface And Applying Two Coats Of Oil Bond Distemper Over A Coat Or Primer, Complete All As Specified And Directed , S&F 6Mm Thick Decorative Pvc Sheet Hollow For Insulation And Acoustic Purpose On Wall/Ceiling Surface, Screw To Timber Frame Work For Levelling Of Wall As Reqd, Including With Panelling To Vectical Surfaces, Fixed With Rawl Plug And Screws, Complete All As Specified And Directed. , Dismantling Of Plain Or Corrugated Steel Sheting, Any Gauge, Thickness, Including Nainital Or Similar Pattern Roof Coverings, All As Specified & Drected By Engr-In-Charge , S&F Pre-Painted Galvalume Aluminium Zinc Oating Gi Based Corrugated Steel Sheeting 0.50Mm Thick Any Colour Having Tensile Strength 550Mpa In Roof Coverings Fixed With Self Tapping Screws Including , S&F Pre-Painted Galvalume Aluminium Zinc Oating Gi Based Plain Steel Sheeting 0.50Mm Thick Any Colour Having Tensile Strength 550Mpa In Roof Coverings/ Cladding To Wall, Fixed With Self Tapping Screws Including , S&F Galvanised, Corrugated 0.63Mm Thick Mild Steel Sheeting Wit Two Corrugations Side Lap, Fixed With L-Type Or J-Type Or Cranked Hook Bolts, With Bitumen Washer/Screws , S&F 0.63Mm Thick Mild Steel Plain Sheeting, Galvanised, In Ridge, Hips, Valley Gutters, Drip And Straight Flashings (Lengths And Girth As Fixed) With Grade Of Zinc Coating 275 Fixed With L-Type Or J-Type Or Cranked Hook Bolts, With Bitumen Washer/ Screws In Normal/Nainital Pattern, All As Specified And Directed. , Demolition Of Concrete In Ground Floors And Paving N Exc 15 Cm Thickness (Below Or Above Ground Level), Complete All As Specified & Directed By Engineer-In-Charge , Dismantling Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc. , M&L For 75Mm Thick Plain Cement Concrete 1:4:8, Type D2 (Using 40 Mm Graded Stone Aggregate) As In Sub Base To Flooring, Complete All As Specified & Directed By Engr-In-Charge. , Providing And Laying 80Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-30 Grade With Approved Colour, Design & Pattern As In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Fine Sand And Cutting Of Paver Block As Per Required Size And Pattern, Finishing And Sweeping Extra Sand; Complete. , Supplying And Laying App Based Modified Water Proofing Polymeric Membrane, Reinforcemed With Nonwoven Polyster Non Wove Fabric Matt (Weight Not Less Than 150 Gms/Sqm) Of Minimum 3 Mm Thick And Minimum Weighing Not Less Than 3 Kg/Sqm,Laid Over Bituminous Primer Conforming To Is 3384-1965 @.30 Kg/Sqm To Be Applied On Prepared Surface And Apply A Coat Of Bitumen 85/25 Grade @1.2 Kg/Sqm Over Primer, 15Mm Thick Plastered Sufaces Layer In Cm 1:4 With Water Proofing Compound (Wpc) @ 3% By Weight On Concrete Surface Roof / Parapet, Over Lap Of Minimum 75 Mm On Longitudinal Direction And 100 Mm On The Transverse Direction By Thermo-Fused Torch Flame Application Method With 02 Coats Of Aluminium Paint Over App Membrane Including Taking Down Of Existing Roof Treatement, Complete All As Specified And Directed. , S&F In Replacement 8Mm Thick, Wooden Pieces, Machine Pressured One Side Laminated And Other Side Balancing Green, As In Parquet Flooring With And Including Necessary Padding As Soft Wool Graded Type As Reuired At Site, Fixed With Adhesive As Per Menufactures Instructions Including Taking Own Old Wooden Flooring With Or Without Plywood Complete All As Specified And Directed. , M&L For 9Mm Thick Plywood, Graded Bwr, Type Bb Fixed With Rawl Plug And Screws To Timber Framework Fixed As In Repair Of Any Thickness Complete All As Specified And Directed. , Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding (But Not Backing), Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Directed. , M&L 15Mm Thick Screed Bed In Cement Mortar 1:6 Under Floor Tiles, All As Specified And Directed. , M & L Anti Skid Ceramic Coloured Tiles Of Size 600X600x7-8Mm , In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match With The Colour Of Tiles Laid On, As Specified.
|