Tender for Cleaning/Removing Blockage Of Wc Indian Or Ewc Including Removing Blockage Of Pipes Upto 1St Manholes Including Necessary T&P Required Complete All As Specified And Directed. , Cleaning/Removing Blockage Of Urinal, Bath Or Kitchen, Gully Trap Including Cleaning Floor Trap And Removing Blockage Of Pipes Upto 1St Manholes Including Necessary T&P Required Completge All As Specified And Directed. , Taking Off Existing Manholes Covers & Cleaning Of Manholes (Any Size / Depth) By De-Watering And Taking Off The Rubbish / Sludge Etc., Removing The Same Upto 50 M Distance And Put Into Newly Excavated Pits Of Suitable Size And Covering With Excavated Earth And Placing Back In Position The Removed Covers Complete All As Specified And Directed. Notes :- 1. The Excavation And Earth Work Of Pit In Any Type Of Soil In Deemed To Be Included In The Unit Rates Of These Items. 2. No Extra Payment Shall Be Made For De-Watering Which Shall Deemed To Be Included In Unit Rates Of These Items. Net Quantity Of Sludge As Removed Shall Only Be Measured And Paid. , Cleaning Of Blocked Sewage Lines (Sgsw/Rcc/Ci Pipes) 150Mm/200Mm Bore Dia Systematically Using Necessary Tools Mechanically And/Or Manually Such As By Rodding, Passing Rope Knots, Bamboo Fanti And Disc Of Required Size (With Safety Measure Such As Dirt And Gas Etc), Flushing The Pipe Well With Water Till Clear Flow Of Sewage From Both Side Between Two Adjacent Manhole Of Any Depth From Both Side Sludge In Semi Liquid Stage Including All Water Effluence Etc And Removing All Materials From Site Of Work Upto A Distance Not Exceeding 50M And Depositing In Earth Pit Of Suitable Size Including Supply And Sprinkling Bleaching Powder And Covering Sludge With Earth After Removal Of Blockage Etc Complete All As Speicified And Directed. , Taking Off Existing Covers Of Septic Tank / Soak Well / Soak Pit & Cleaning The Same Of Any Size / Capacity By Dewatering And Taking Out Sludge In Liquid, Mud, Silt Or In Solid State After Emptying The Water By Manual Or By Mechanical Means And Removing The Sludge To A Distance Not Exceeding 50 M And Burying The Sludge In Newly Excavated Pits Of Suitable Sizes And Covering The Same With Excavated Earth And Placing Back In Position The Removed Covers Complete All As Specified And Directed. Notes :- 1. The Excavation And Earth Work Of Pit In Any Type Of Soil In Deemed To Be Included In The Unit Rates Of These Items. 2. No Extra Payment Shall Be Made For De-Watering Which Shall Deemed To Be Included In Unit Rates Of These Items. Net Quantity Of Sludge As Removed Shall Only Be Measured And Paid. , Supply & Fixing In Repairs Plain, Galvanised, Mild Steel Sheeting, Cover With Suitable Nos Of Spikes On Top Of Cover For Rotational Moulder Polythene Water Storage Tanks Of 500 Litre / 1000 Liters Capacity Including Necessary Securing And Locking Arrancement With Nuts, Bolts, Hasp Staple And Washers Complete All As Specified And Directed. , S & F In Repairs 110 Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls Including Necessary Iron Clips Fixed With Screws / Nails Complete All As Specified And Directed. , S & F In Repairs 110 Mm Bore Pvc Bends In Any Radius Diminishing Piece Or Taper (Larger Bore Measured) Complete All As Specified And Directed. , S & F In Repairs 75 Mm Bore Pvc (Swr) Pipes Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls Including Necessary Iron Clips Fixed With Screws / Nails Complete All As Specified And Directed. , S & F In Repairs 75 Mm Bore Pvc Bends In Any Radius Diminishing Piece Or Taper (Larger Bore Measured) Complete All As Specified And Directed. , Cleaning And Removing All Scale And Dirt, Etc And Form Mouths Of Circulating Pipes, Etc And Hoisting Or Reconnecting And Re-Fixing In Position After Cleaning Tanks Of Capacity Exc 250 Liters & N Exc 500 Liter Complete All As Specified And Directed. , Cleaning And Removing All Scale And Dirt, Etc And Form Mouths Of Circulating Pipes, Etc And Hoisting Or Reconnecting And Re-Fixing In Position After Cleaning Tanks Of Capacity Exc 500 Liters & N Exc 1000 Liter Complete All As Specified And Directed. , Excavation In Trenches Not Exc. 1.50 M Wide And Not Exc. 1.50 M In Depth For Foundation Etc. Or For Manholes, Cesspits, Shafts Etc. Not Exc. 10 Sqm On Plan And Getting Out In Hard / Dense Soil Complete All As Specified And Directed. , Demolition And Breaking Up Drain Pipes (Salt Glazed Ware, Ac Or Reinforced Concrete) Set In Cement Mortar Of 150Mm Dia In Foul Condition Including Removing The Debris To Distance Not Exc. 50 M And Depositing Where Directed , M & L For 150 Mm Bore Salt Glazed Stoneware Drain Pipes Grade A Laid In Trenches And Jointed In Cement Sand Mortar 1:1 With Spun Yarn Complete All As Specified And Directed. , M & L For Cement Concrete 1:3:6, Type C-2 (Using 40 Mm Graded Crushed Stone Aggregate) As In Bed To Drain Pipes Of 150 Mm Bore Including Packing Under And Haunching Against The Side Of Pipe After They Are Laid And Tested Complete All As Specified And Directed. , Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 25 Cm Thick In Each Layer As In Hard / Dense Soil Complete All As Specified And Directed. , Removing Surplus Excavated Material (Soil) To Distance Not Exc. 50 M And Depositing Where Directed At A Level Not Exc. 1.50 M Above The Starting Point Complete All As Specified And Directed. , Demolition Of Reinforced Cement Concrete In Any Position And Any Description Including Cutting Of Reinforcement Bars To Facilitate Demolition Complete All As Specified And Directed. , M & L For Providing Pre-Cast Cement Concrete Landing, Cover Slabs, Chulla Hoods, Chajjahs, Shelves And Similar Items With Plain Faces In Cement Concrete 1:2:4 Type B-1 Using 20 Mm Graded Crushed Stone Aggregate And Setting In Cement Mortar 1:4 Complete All As Specified And Directed. , M & L For Mild Steel Tmt Bars 6 To 8 Mm Dia, Cut To Length, Bent To Shape Required Including Cranking, Bending Spirally For Hooping For Columns And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And Directed. , Demolition Of Precast Plain Cement Concrete Block Masonry / Brick Work Or Stone / Boulder Masonry Including All Quions, Arches, Pillars, Etc Built In Cement Mortar Or Cement Lime Mortar Complete All As Specified And Directed. , M & L For Brick Work With Sub Class B Old Size Bricks Straight Or Curved On Plan Exc, 6.00 M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed. , M & L For Providing Plain Cement Concrete Type B-1, 1:2:4 (Using 20 Mm Graded Crushed Stone Aggregate) As In Coping, Bed Block For Embedding Hold Fasts, Kneelers, Apex Stones, Bed Plates, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles & Throating As Directed Including Necessary Form Work As Required Complete All As Specified And Directed. , M & L For Cement Concrete 1:3:6 Type C-2, Using 40 Mm Graded Crushed Stone Aggregate As In Surface Channel Or Drain Complete All As Specified And Directed. , Taking Down Cement Or Cement Lime Plaster From Brick Work Or Stone Wall Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. Complete All As Specified And Directed. , M & L For Rendering 15Mm Thick In Cm 1:4 Fair Faces Of Wall Surfaces Of Brick Work Or Concrete Surfaces Rendering Is To Be Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. , M & L Preparing Newly Plastered Surfaces Of Walls And Applying Two Coats Of Cement Base Paint Over A Coat Of Primer Complete All As Specified And Directed. , Demolition Of Cement Concrete (Un-Reinforced) In Ground Floor And Paving Not Exc. 15 Cm Thick (Below Or Above Ground Level) Complete All As Specified And Directed. , M&L For 75Mm Thick Plain Cement Concrete 1 : 3 : 6 Type C-2 (Using 40 Mm Graded Stone Aggregate) As Sub Floor Or Sub Base Or Similar Work Including Necessary Form Work Complete All As Specified And Directed. , M& L For 40Mm Thick Plain Cement Concrete 1:2:4 Type B1 (Using 20Mm Graded Stone Aggregate) As In Floors And Finishing The Top Surfaces Even And Smooth Using With Extra Cement Complete All As Specified And Directed. , M&L For Chequered Cement Concrete Tiles 25Mm Thick With Mixture Of Grey Cement And Pigment In Reqd Proportion, Set,Area Of Each Tile Exceeding 0.05 Sqm But Not Exceeding 0.09 Sqm, Jointed And Pointed In Near Cement Slurry In Floors,Laid On Screed Bed Or Bedding Layer Of Mortar 15Mm Thick 1:6 Cement Mortar Complete All As Specified & Directed , Demolition Of Cement Concrete (Unreinforced) In Ground Floors And Pavings Exceeding 15 Cm Thickness.(Below Or Above Ground Level) Complete All As Specified And Directed. , M&L For Cement Concrete Type D-2 1:4:8 (40Mm Graded Aggregate) In Foundations, Filling,Sub Base And Mass Concrete Complete All As Specified & Directed By Engr-In-Charge. , M&L For Sand Filling Under Interlocking Tiles Or In Foundations Including Watering And Consolidation Complete All As Specified & Directed By Engr-In-Charge. , M&L Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 80 Mm Thickness M-40 Grade Complete All As Specified By Engr-In-Charge. , M&L For Plain Cement Concrete 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregate As In Coping /Kerbing/Side Of Interlocking/Flooring/Hardstanding Etc.Including Weathering And Throating Including Necessary Form Work Etc.Complete All As Specified And Directed. , M&L For Repair Of Pot Holes Any Depth N Exc 1.5 Sqm In Cross Section Each Including Sweeping Free From Dust ,Mud, Water Sunken Surfaces In Roads , Paths, Hardstandings Etc, Cutting Around Edges To Atleast 25 Mm In Depth And Filling The Pot Holes With Instant Road Repair Bituminous Material Having Avg Aggregate Size Between 6 Mm To 10 Mm And Density Not Less Than 2200 Kg/ Cum And Minimum Bitumen Content Not Less Than 6% , Complete All As Specified And Directed By Engg-In -Charge. , Excavating In Post Holes (Or Similar Holes) In Hard/Dense Soil Each N Exc 0.5 Cu. M, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm Complete All As Specified & Directed. , Dismantling Posts Or Struts (Wood, Steel Or R.C.C.) Any Section Embedded In Pcc, Including Taking Out Embedded Portion And Making Good Disturbed Ground Complete All As Specified & Directed. , Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete All As Specified & Directed. , Dismantling Chain Link Fencing Wire Mesh, Any Type & Size Complete All As Specified & Directed. , M&L For Plain Cement Concrete Type D-2 1:4:8 (40Mm Graded Aggregate) In Foundations, Filling And Mass Concrete Complete All As Specified & Directed. , M&L For Ms Work In Hand Rails, Half Round Or Other Steel Section Or Core For Wooden Hand-Rail Straight Portion, Drilled And Countersunk For Balusters Running Bars, For Doors, Balusters, Nosing To Steps Including Embeding In Concrete And Screwing Etc. Wind Ties For Roof Including Securing Bolts;Posts And Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes,Notching For Wire, Etc.; Flat Iron Fillets (For Securing Wire Mesh Etc.) Including All Necessary Drilling, Bolting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified & Directed. , Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standards, Rails, Straining Bolts, Etc. Including Provission Of Binding Wire Complete All As Specified & Directed. , Supply Only Chain Link Ms Galvanisd Fencing, Any Size Or Type Complete All As Specified & Directed. , M&L Tmt Mild Steel Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, As Reinforcing Bars In Chain Link Fencing Fixed Complete All As Specified & Directed , S&F In Repair Galvanised. 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails Strain- Ing Bolts, Including, Securing Or Tying At Crossings With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins, Etc. As Directed (Each Line Wire To Be Measured) Complete All As Specified & Directed. , Restraining, Resecuring Including Making Good Staples Etc Galvanised. 2 Strand, Steel Barbed Wire 2.24Mm Dia Barbed With 2Mm Dia Barbs At 75Mm Spacings And Straining And Fixing To Any Type Of Standard Rails Strain- Ing Bolts, Including, Securing Or Tying At Crossings With And Provision Of Galvanised Mild Steel Wire, Staples Or Steel Pins, Etc. As Directed (Each Line Wire To Be Measured) Complete All As Specified & Directed. , M&L Mild Steel Screw Bolts (Machine Made) 11 To 15Mm Dia With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Exc 5Cm But Not Exc 10Cm Long Complete All As Specified & Directed. , Dismantling Structural Steel Work Including Doors, Gates But Excluding Framed Truss Etc. Complete All As Specified & Directed. , S & F Ms Framed Work Such As Grills, Gratings,Gates Etc., With End Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders Framed Balusters; Walk Ways; Railings; Frame Work Of Water Tanks And Similar Work Conforming To Fe 190-0 Or Fe-165-0. , M & L For Painting To New Steel And Iron Surfaces Of Any Description, Over 10 Cm In Width Or Girth, Not Otherwise Described With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Including Preparation Of Surfaces Complete All As Specified And Directed. , M & L For Painting To New Steel And Iron Surfaces Of Any Description, Not Exc 10 Cm In Width Or Girth, Not Otherwise Described With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Including Preparation Of Surfaces Complete All As Specified And Directed. , Supply Of Kiwi Mr. Muscle Drainex Drain Cleaner Powder, 375 Grams Pack, Or Equivalent Approved Brand, Suitable For Clearing Kitchen Sink, Wash Basin, Floor Trap And Toilet Drain Blockages. The Product Shall Be Strong Caustic-Based Drain Cleaner (Powder Form), Fast Acting, Safe For Pvc/Ci Pipes When Used As Per Manufacturer Instructions, And Supplied In Original Sealed Packing.
|