1) The Subject Of The Order Are Construction Works Related To The Performance Of Thermal Modernization Works Of A Multi-Family Residential Building Located At Ul. Nowe Osiedle 2. The Building Is Part Of A Complex Of Multi-Family Buildings Built During World War Ii, Included In The Municipal Register Of Monuments. A Single-Staircase Building, Built On A Rectangular Basis, With A Basement, Two Storeys Above Ground With An Attic Partially Used For Residential Purposes. The External Walls Are Made Of Brick, The Gable Roof Is Covered With Corrugated Asbestos Boards. 2) Characteristic Parameters Of The Building: A) Volume After Thermal Modernization: Approximately 1785 M3, B) Usable Area: 727.61 ÷ 747.19 M2, C) Building Area After Thermal Modernization: 271.11 M2, D) Height After Thermal Modernization: 11.64 M, E) Length After Thermal Modernization: 28.40 M, F) Width After Thermal Modernization: 9.68 M2, G) Number Of Floors: 3 Above-Ground And 1 Underground. 3) The Scope Of Works Includes: A) Replacement Of Part Of The Window Joinery With White Pvc, B) Replacement Of External Window Sills With Window Sills Made Of Galvanized Coated Sheet Metal (In The Entire Building), C) Replacement Of External Door Joinery, Entrance Doors To The Apartments (From The Staircases) And Door Joinery Separating The Attic From The Usable Part Of The Attic, D) Insulation Of External Walls With Thick Polystyrene. 20 Cm And Covered With Gray Silicate-Silicone Plaster, The Window Recesses Will Be Leveled With A Layer Of Styrofoam Thickness. 5 Cm, With Preparation Of The Substrate Consisting Of Chipping Away Existing Plasters, Filling In Any Missing Bricks, Washing And Priming The Walls, E) Installation Of Stucco Elements On The Facade - Cornices And Moldings Around Doors, F) Dismantling, Removal And Disposal/Storage Of The Roof Covering Made Of Corrugated Asbestos-Cement Boards, G) Fire And Anti-Fungal Protection Of The Roof Structure, H) Insulation Of The Roof Slope Attic Flat Roof With Mineral/Glass Wool With Vapor Barrier, I) Roof Covering With Metal Tiles On New Battens And Counter Battens, With A Windproof Membrane, With Replacement Of Sheet Metal Flashings, J) Replacement Of The Rainwater Drainage System With Galvanized Pipes And Gutters In The Color Of Matt Graphite, K) Replacement Of Parts Of The Roof Structure Elements, L) Strengthening Of The Roof Structure By Fastening On Both Sides To The Rafters Boards,M) Repairs Of Chimneys With Their Insulation And Chimney Caps,N) Installation Of Roof Hatches, Steps And Chimney Benches,O) Backfilling Of The External Descent From The Ground Level To The Basements, With Bricking Up The Door Opening And Wall Insulation,P) Replacement Of External Staircase Balustrades,Q) Construction Of A Band Around The Building.4) A Detailed Description Of The Subject Of The Order Is Attached As Annex No. 1A To Swz - Design Documentation - Part 1.
|