|
Tender For Short Term E-Bid For Rate Contract Cum Supply And Empanelment Of Surgical Items , Absorbable Surgical Suture (Sterile Catgut),Bp/Usp Needled Suture Chromic (L/2 Cir Rb Needle 20Mm Length 76 Cm) Size-3/0 , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 16G • Should Be Packed In Transparent, Single Blister Pack. • As Per Is 10555 Standard , Surgical Blade Sterile, Size 11 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • As Per Is 3319(Bis Mandatory) , Surgical Blade Sterile, Size 15 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • As Per Is 3319(Bis Mandatory) , Standard Pmma Intra Ocular Lenses (Size + 18 D To + 24 D) • 6Mm Optic Size 12.5 - 13.0 Mm Total Diameter, Biconvex 1. Pmma Optics And Haptics Single Piece With Hole 2. 6Mm Optic Size 12.5 To 13Mm Total Diameter, Biconvex 3. Iol Haptics - Modified C Shaped With 5° -10° Anterior Angulation. 4. Should Have 360° Square Edges. 5. Iol Should Have Uv Blocking Capability 6. Diopters- + 18 D To + 24 D At 0.5 D Step. 7. Supplying Unit Should Be Iso Accredited And Iol Should Be Ce/Us Fda Certified. , Chemotherapy Port &Non-Coring Needles(Adult) • Valved Catheter Need Only Saline Flush, Catheter With Intermediate Size Port With Small Septum And Silicon Filled Suture Holes, Should Be Mri Compatible With Cathlock Radio- Opaque Ring. 8Fr With Silicon Material With Peel Apart Percutaneous Introducer System. • Chemo Port Huber Needle 20G And 22G. , Chemotherapy Port &Non-Coring Needles(Pediatric)• Catheter Need Only Saline Flush, Catheter With Intermediate Size Power Port With Large Septum And Silicon Filled Suture Holes, Should Be Mri Compatible With Cathlock Radio-Opaque Ring. 6Fr With Silicon Material With Peel Apart Percutaneous Introducer System• Chemo Port Huber Needle 20G And 22G. , Eye Pressure Shield Should Be Made Up Of Soft Foam And Rigid Plastic Shield, Length Of 178 To 185 Mm And Width Of 83 To 88Mm, Foam Thickness Of 17 To 19Mm. Plastic Type Triton Tx- 2001, Enough Holes On Nasal Rib And Either Side Of The Shield To Prevent Condensation, Weight Not More Than 50Gms, Ce Certified. , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape Size Large Left 10.8*16Cm /15*10 Cm , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape Size Large Right 10.8*16Cm /15*10 Cm , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape Size Extra Large Left 12.4Cm * 17.3* /16*12 Cm , Light Weight Monofilament Polypropylene Mesh, Design To Confirm Inguinal Anatomy, 3D Shape Size Extra Large Right 12.4Cm * 17.3*/16*12 Cm , Curved Cutter Stapler 40 Mm Linear Cutter Simultaneous Cutting And Stapling , Disposable Laparoscopic Clip Applier Preloaded With 15/16 Clips, 5Mm Diameter With Clip Logic Technology And Digital Display Titanium Clips -U Shaped , Synthetic Oxidised Re-Generated Cellulose Double Layered With Peg And Trilysine Size 2*4Cm Or Size 2- 3*5-6Cm , Aortic Punch 3.6 Length Betwwen 6 To 7 Midlength Diamond Edge Sharp, Dual Cut Edge For Clean Precise Removal Of Aortic Tissue,Conical Tip Or Round / Eliptical Tip For Easy Insertation By Straight Or Button Hole Tech, Should Have Long And Short Handle Confirguaration, Sterile Packing , Ionic Silver Highly Absorbent Multilayer Foam Dressing With Broad Spectrum Antimicrobial , Bactericidal Efficacies And Having A Soft Siliconadhesive Wound Contact Layer , Providing Sustain Release Of Silver Upto 7 Days. Size: 10 Cms X 10 Cms And More , Self-Adherent Moist Wound Foam Dressing Made Up Of Multilayer Matrix With Soft Silicon Adhesive Layer For Pressure Ulcers/Bed Sores At Sacrum 16 Cms X 20 Cms And More , Infant Prong Cpap Cannula Infant Prong Cpap Cannula Nasal Size 0 With Designed To Reduce Trauma Associated With Delivery Of Infant Nasal Cpap. Must Be Soft Siliconised, Anatomically Curved Prongs To Enhance Fit. Luer Fitting On Expiratory Connector To Allow Proximal Airway Pressure Monitoring. Each Set To Include, Soft Siliconised Cannula; Inspiratory & Expiratory Elbow Connector; Knit Cap; Two 6 In. Hook And Loop Fastener Sections; Two 10 To 7.5 Mm Adaptors. Manufacturer Must Be Usfda Registered / Certified With En/Eu Iso 13485 / Applicable 510K & Ce Certification. , Hydrophillic Braided Sheath Hydrophilic Braided Sheath Introducer In 4F To 7F, Length: 7Cm, 10-11Cm, 15-16Cm, 23-25Cm Or 7-25 Cm With The Option Of .018, .021, .025 Plastic Jacketed And Spring Coil Guidewire. Should Have Ultra-Thin Wall And Flat Wire Braiding Technology To Provide Support And Low Profile.Usfda Approved , Femoral Sheath With Needle Femoral Sheath In 5F To 8F, Length: 11-25Cm With Puncher Needle Of 18G And Guidewire Of .035, .038. Should Have Rotating Suture Ring, Snap-Fit Dilator To Prevent Slipping During Insertion And Holster Pack. Should Be Available In Polypropylene. Usfda Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning. Separate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes 8Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning.S Eparate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes Are 10Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter For Paediatrics Number And Color- Coded Graduations For Controlled Depth Suctioning. Separate Y Connectors Available For Different Tubes In The Pack. Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material. Sizes 12Fr. Usfda/ Notified Ce Approved , Closed Suction Catheter Mdi Port Has Isolated Cleaning Chamber For Cleaning Catheter Tip With Mdi Port. Catheter Is Made Up Of Medical Grade Silicon/Poly Urethane Material, Catheter Has Zigzag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version. Can Be Used For 72Hr. Size 12-Fr Product Should Be Usfda Approved , Closed Suction Catheter Has Isolated Cleaning Chamber 12 Fr. Closed Suction Catheter Has Isolated Turbo Cleaning Chamber For Cleaning Catheter Tip.Catheter Is Made Up Of Medical Grade Silicon/ Poly Urethane Material,Catheter Has Zig-Zag Ports For Better Suctioning. Available In Both Endotracheal And Tracheostomy Version.Can Be Used For 72Hr. Size 12 Fr. , Central Line With Triple Lumen With Y Needle With Syringe And Guide Wire 7Fr To 8.5Fr With 15 Cm To 20 Cm Catheter With Tecoflex/ Polyurathane Material With Usfda Approved. , Sterile Self Adherent With Lipido Colloid Technology / Safetac Layer Sterile Self -Adherent Patented Tlc Matrix (Lipido Colloid Technology) Wound Contact Layer Combined With Absorbent Polyurethane Foam Pad, A Superabsorbent Layer, A Vapour Permeable Waterproof Outer Film With Soft Silicone Adhesive Border On The Edges For Atraumatic Removal And Repositioning Of Dressing. Size 10X25 Cm , Sulu Stepped Cartridges For Variable Tissue Application , Fixed Anvil , Different Leg Length Staples In Same Cartridge , Inbuilt Knife ,Size 60 Mm Inner To Outer Side 3.0,3.5 And 4.0 Mm , Purple Colour Code, Usfda Approved 10Mm , Flexomatlic Tube 3-8.5 With Stylet Reinforce Et Tube With Wiring From Tip To End. It Should Be Approved By Usfda. , Vdrl Antigen (With +Ve And -Ve Control) / Rpr Slide Kit :- Specification For Rpr _Rapid Plasma Regain) Slide Test For Detection Of Regain Antibodies In Syphilis 1. Rapid Plasma Reagin Test Kit Having Non- Treponemal Cardiolipin Antigen Coated Carbon Particles Used In The Detection Of Regain Antibodies In Serum / Plasma Of Suspected Cases Of Syphilis By The Flocculation Reaction. 2. The Kit Should Be Meant For Qualitative And Semi Quantitative Detection Of Regain Antiboidies Against The Non-Treponemal Cardiolipin Antigen. 3. Sensitivity & Specificity Should Be 95% Or More. 4. Positive & Negative Control Serum Should Be Provided With The Kit For At Least 10% Of The Tests In Each Kit. 5. The Kit Should Have Shelf Life Of Minimum 12 Months Or More At The Time Of Delivery Of Consignment. The Kit Should Be Stored At 2° C - 8° C. 6. Adequate Literature Detailing The Principle, Components, Methodologies, Validity Criteria. Biosafety, Performance Characteristics,Storage Conditions, Limitation Of Assay, Manufacture And Expiry Dates And Methods Of Disposal Should Be Provided With Each Kit. 7. The Test Should Be Free From Possible Interferences With Potentially Cross Reactive Sera. 8. All The Test Kits Should Be Provided With Necessary / Required Disposable Accessories In Sufficient Quantity. 9. The Imported Kit Should Have Approval Of The Statutory Authority In Its Country Of Origin . The Imported Kits Should Have Been Registered And Licensed In India By The Cdsco. (Central Drugs Standard Control Organization) , Double Blood Bags With Sagm (350Ml) General Specifications Annexure- Xvi And Specification In Annexure- Xxiii
|