|
Mini Soil Laboratory. Photometer With Charger And Instruction Manual Automatic Pipette 0.2-1.0 Ml Automatic Pipette 1.0-5.0 Ml Tip 0.2-1.0 Ml (100 Pcs.) Tip 1.0-5.0 Ml (75 Pcs.) Test Cuvette Holder Battery Aluminum Case Test Cuvette For Nitrates (25 Pcs.) Test Cuvette For Ammonium (25 Pcs.) Test Cuvette For Phosphates (25 Pcs.) Test Cuvette For Potassium (24 Pcs.) Test Cuvette For Magnesium (25 Pcs.) Extraction Equipment: Case With Equipment For Preparing Soil Samples Laboratory Scales With A Solar Battery, Division Value 1 G Plastic Funnel O 120 Mm (6 Pcs.) Wide Neck Extraction Bottle, 1 L (6 Pcs.) Bulk Bottle 100 Ml (6 Pcs.) Measuring Bottle With Graduation, 1 L Test Tube With Screw Cap (8 Pcs.) Test Tube Holder Aluminum Case Folded Paper Filter (100 Pcs.) Extracting Concentrate, 1 L. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Laboratory Conductivity Meter. A Device For High-Precision Measurement Of The Electrical Conductivity Of Solutions, Which Can Also Determine Salt Concentration And Temperature, Based On The Ability Of The Liquid To Conduct Current. Ph Range -2.000 To 20.000. Ph Resolution User-Definable: 0.001 / 0.01 / 0.1. Relative Ph Error ± 0.002. Dimensions No Less Than 204X174x74 Mm. Weight Not Less Than 0.9 Kg. Built-In Usb And Rs-232 Interfaces For Data Transfer To A Pc, Printer And Usb Card Using Labx Software (Optional); The Uplace Tripod With A Fully Vertical Electrode Stroke Is Supplied As Standard And Provides The Most Convenient And Safe Position For The Electrode For Measurements, Which Allows For Faster Measurements And Reduces The Risk Of The Sample Container Tipping Over And Damaging The Sensor. It Is Possible To Mount It Both To The Right And To The Left Of The Device, As Well As To Install It Separately From It. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Distiller With Storage Tank 12 L. An Automatic Device That Produces Purified (Distilled) Water From Tap Water, Immediately Collecting It In A Special Built-In Reservoir, Which Is Convenient For Medical, Laboratory And Domestic Needs, Providing A Constant Supply Of Quality Water Without The Need For Separate Collection. Distiller Productivity Is Not Less Than 12 L/H, Distillate Conductivity, Μsiemens/Cm At 25 Oc 2.3, Storage Tank Volume Is Not Less Than 24 L. Cooling Water Consumption, L/Min 3.3. Dimensions Of The Distiller Are Not Less Than (W X D X H), Mm 780 X 410 X 670. Power Supply, 380 V. Power, 9.0 Kw. Weight Not Less Than 40.5 Kg. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Micropurka Grain. A Laboratory Instrument For Accurately Determining The Nature Of Grain (Bulk Density, G/L), A Key Quality Indicator That Shows The Weight Of One Liter Of Grain, Helping To Assess Its Completeness And Suitability For Various Purposes. Measurement Volume, 1 L. The Division Price For A Load Of 1 Kg, G, Is Not More Than 0.25. Permissible Error Limit, G 0...4. The Range Of Readings From 6 Observations, G, Is Not More Than 2.1. Sensitivity Of The Beam At A Load Of 1 G, Divisions, Not Less Than 4. Error Due To Unequal Arms Of The Rocker, G, No More Than 0.5. Rocker Arm – Aluminum Alloy, Prisms And Cushions – Steel. Cup – Aluminum Alloy, Diameter, 130 Mm. Suspension Height, 280 Mm. Overall Dimensions No Less Than 500×350×200 Mm. Weight Not Less Than 4 Kg. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Inter-Row Cultivator. 1. Working Width (M) 4.2 2. Number Of Rows (Pcs) 6 3. Row Spacing (Cm) 70 4. Fertilizer Seeding Rate (Kg/Ha) 50-250 5. Working Speed (Km/H) 5-10 6. Processing Depth (Cm) 6-16 7. Overall Dimensions (Mm) 4875X2100x1700 8. Weight (Kg) Not Less Than 670 9. Tractor Power (Hp) 80 10. The Parallelogram Suspension Of Sections Of Working Bodies Has Increased Rigidity, Which Eliminates Damage To Crops And Ensures Copying Of The Soil Topography. All Components Are Mounted On Rolling Bearings. Atmospheric Gauge Wheel Tire Ensures Self-Cleaning During Operation 11. Availability Of Technical Passports, Certificates Of Product Conformity., Muffle Furnace. Laboratory And Industrial Heating Device With An Internal Heat-Resistant Chamber (Muffle) That Isolates The Heated Material From Heat Sources Muffle Furnace With Stone Insulation. - Tmax 1300 °C. - Lifting Door Type; - Maximum Temperature Not Less Than 1300°C; - Heating Time To Max. Temp. 60 Min; - Chamber Volume Is At Least 15 L; - Internal Dimensions No Less Than (Wxdxh) 230 X 340 X 170 Mm; - External Dimensions Not Less Than (Wxdxh+Open Lifting Door) 480 X 650 X 570+290 Mm; - Weight Not Less Than 70 Kg; - Power Consumption No More Than 3.6 Kw; - Electrical Network 1-Phase Voltage (110V - 240V, 50 Or 60 Hz). Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Ionomer. A Device For Accurately Measuring The Concentration Of Various Ions (Primarily Hydrogen, That Is, Ph, As Well As Cations And Anions) In Solutions, Based On The Potentiometric Method (Measuring The Electromotive Force In The Electrode System). Converter. Thermal Sensor Tdl-1000-06. Ph Electrode Es-10603/7. Reference Electrode Esr-10103. A Set Of Devices For Carrying Out Measurements. Tripod. Mains Power Supply. Form. Operation Manual. Output: Digital C2 (Rs-232C), Analog 2V; 100Mv. Output Voltage Accuracy +/-0.25%. Graphic Lcd Display. Power Supply 220V, Frequency 50-60 Hz. Weight Not Less Than 1.5 Kg. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Electric Dry Air Thermostat. Designed To Maintain A Set Temperature In Its Working Chamber For A Long Time, Which Is Necessary For Conducting Various Biological And Medical Studies. Volume, L 80 Operating Temperature Range, °C, Ambient Temperature +5 - 60 Amplitude Of Temperature Fluctuations At Any Point In The Working Volume, °C ±0.4 Maximum Deviation Of The Average Temperature Of Any Point Of The Working Volume From The Set One Under Steady-State Thermal Conditions, °C, No More Than: 1) Up To +45°С Inclusive; 2) From +45°С To +60°С 1) From -1 To +1; 2) From -1 To +2 Time To Establish The Operating Mode At The Maximum Temperature In The Working Chamber, Min, No More Than 120. Time Of Continuous Operation Of The Thermostat In Automatic Mode, Hours, No Less Than 500. Dimensions Of The Working Chamber, Mm, No Less: Width × Depth × Height 400×406×500. Overall Dimensions, Mm, No More: Width X Depth X Height 512×525×721. Material: Paint And Varnish Coating. Supply Voltage/Frequency, V / Hz 220±10% / 50. Power Consumption, Kw, No More Than 0.3. Weight, Kg, No More: Without Packaging And Without Accessories – 36. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Analytical Balances. A High-Precision Laboratory Instrument Designed To Measure The Mass Of Substances With Extreme Accuracy, Typically To 0.1 Mg (0.0001 G) Or Better. Max 220G, Min 0.01G, Resolution 0.0001G. Accuracy Class Special (I) According To Oiml R 76-1-2011. Lcd Display With Backlight. Platform Size Ø80 Mm. Calibration Is Internal. Rs-232C Interface. Dimensions No Less Than 290X200x306 Mm. Availability Of Technical Passports, Verifications, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Grain Moisture Meter. An Instrument Designed To Measure The Percentage Of Water In Various Substances Or Materials, Such As Grain Or Soil. Microprocessor-Based, Based On Measuring The Dielectric Constant Of The Sample. The Range Of Measurement Of Grain Moisture Content Is From 8 To 35%. The Measurement Range For Oilseed Moisture Content Is From 6 To 25%. Operating Range Accuracy Greater Than 1%. Operating Range Accuracy Greater Than 1%. Powered By 9B Battery. Weight Not Less Than 1.5 Kg. Storage Temperature From -15 To 55 °C. Digital Display For At Least 16 Types Of Grain, 5 Types Of Flour And Bran. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Diaphanoscope. Determining The Glassiness Of A Grain By Its Optical Properties, Consists Of A Body; Cassette Movement Mechanism; Light Source - Leds; Magnifying Lenses. The Grain Samples Under Study Are Placed In One Hundred Cells Of A Cassette, Which Is Inserted Into The Inlet Hole Of The Broaching Unit Until It Engages With The Feed Rollers. Using The Feed Screw, The Cassette Moves To The Visual Observation Zone Of Each Row Of Grains, Illuminated By The Light Flux. Power Supply 220 V. Power Consumption No More Than 5 W. Cassette Capacity 100 Grains. Weight No More Than 4.0 Kg. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Laboratory Mill. Specialized Equipment Designed For Grinding And Homogenizing Various Materials For The Purpose Of Sample Preparation For Further Analysis. Power Supply 220V. Power Consumption 220W. Operating Mode – Intermittent 5 Minutes Of Work, 10 Minutes Of Break (One Cycle). The Capacity Of The Glass Is 130 Cm3. Grain Weight, Maximum 50 G. Rotation Speed Of The Electric Motor Shaft At Idle, Not Less Than 10,000 Rpm. Weight Not Less Than 1.5 Kg. Overall Dimensions No Less Than 108×182 Mm. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Laboratory Scales. Weighing Limit: No More Than 320 G, No Less Than 0.02 G, Resolution 0.001 G. Accuracy Class - High (Ii) According To Oiml R 76-1-2011, Lcd Display With Backlight. Platform Size Ø140 Mm. External Calibration 200Gf1 (Weight Not Included!). Possibility Of Autonomous Power Supply (From Batteries - Option). Rs-232C Interface. Dimensions No Less Than 293X202x206 Mm, Including Wind Protection. Operating Manual In The State Or Russian Language. Certificate Of Initial Metrological Verification Included. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Drying Cabinet. Laboratory Equipment Designed For Fast And Gentle Drying By Circulating Hot Air. Chamber Volume, Not Less Than 32 Liters; Chamber Material: Stainless Steel Tool Steel 1.4301 (Astm 304), Solid Drawn. Design Heating Elements Are Located On Four Sides; Operating Temperature Range From 5 °C Above Room Temperature With Natural Convection To 300 °C; Max. Temperature Sensor 1 Pt100 Din Class A Sensor In 4-Wire Version. Number Of Shelves: 1; Std. Number Of Shelves:1; Power, W:800-1600; Voltage, W: 200. The Size Of The Internal Chamber Is At Least W X H X D: 400 X 320 X 250 Mm (-39 Mm Of The Total Depth Is Occupied By The Fan). Case Dimensions Not Less Than W X H X D: 585 X 704 X 434 Mm (Excluding Door Handle Protrusion (+56 Mm). Net Weight Not Less / Gross Weight 45 Kg / 61 Kg. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Thermostat With Natural Convection. To Accurately Maintain The Temperature Inside The Chamber Due To Natural Air Movement (Heated Air Rises, Cold Air Falls), Ensuring Uniform Heat Distribution Without Vibration And Minimal Contamination Of Samples. Working Volume: Not Less Than 108 L; External Dimensions: 745 X 864 X 584 Mm; Operating Temperature Range: From 5°C Above Ambient Temperatures Up To 80°C. Number Of Shelves Included/Maximum: 2/6 Load On Cabinet, Kg: 175 Power Supply: 230 V, 50/60 Hz Power, W: 1400. Electronic Pid Process Controller With A Self-Diagnostic System For Quick Fault Detection. • Touchpad To Navigate Between Settings • Air Damper With Servo Drive And Opening Adjustment 0-100% For Air Exchange • Programmable Timer Up To 99 Days 23 Hours. • Color Tft Display For Displaying The Set And Actual Temperature, The Degree Of Opening Of The Air Damper, The Process Time As Well As Menu Settings. • Mechanical Temperature Limiter (Tv, Class 1). • Optical Alarm Indicator. • Platinum Temperature Sensor Pt100. • Ethernet Port On The Rear Panel For Logging The Drying Process • Built-In Logging System. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier., Drying Cabinet. Volume Not Less Than 80 L, Operating Temperature Range, °C +50/+200, Maximum Temperature Deviation At The Control Point Of The Working Chamber From The Set Temperature, °C, No More Than ±6. The Accuracy Of Maintaining The Temperature In The Working Chamber In A Steady State Is No Worse Than °C ±3. Heating Time To Maximum Temperature, Min, No More Than 30, Continuous Operation Time, Hours, No Less Than 16, Dimensions Of The Working Chamber, Mm, No Less: Width × Depth × Height 560X390x370, Overall Dimensions, Mm, No More: Width X Depth X Height 680X626x603. Power Consumption, Kw, No More Than 1.6. Supply Voltage/Frequency, V / Hz 220±10% / 50 . Weight, Kg, No More: 27. Availability Of Technical Passports, Certificates Of Conformity Of Products Specified In The Technical Specifications Of The Potential Supplier.
|