Nylon Cable Tie Tie, Length *230* Af_07/2020, Secondary Frame, With 1 Stirrup And 1 Insulator - Supply And Installation. Af_07/2020, 01/30/2026 - 13:56:03, Vertical Frame With Rod And Cotter Pin, In Galvanized Steel Sheet 3/16, With 1 Stirrup And 1 Insulator, Galvanized Steel Washer, External Dia-Meter = 35Mm, Thickness = 3Mm, Hole Diameter= 18Mm, Aluminum Washer, With Thread, 1 1/2, For Conduit, 2, Square Washer In Galvani-Zed Steel, Dimension = 38 Mm, Hole Diameter = 18 Mm, Concrete Post Seating With Nominal Length Of 12 M, Nominal Load Greater Than 1000 Dan, Simple Embedment With 1.8 M Of Soil (Does Not Include Supplies). Af_04/2025, Nominal Load Less Than Or Equal To 1000 Dan, 8 M Of Soil (Does Not Include Supply). Af_11/2019, Laying Of Concrete/Steel/Fiberglass Post With Nominal Length Above 12 M, Embedment In Earth, Laying Of Concrete/Steel/Fiberglass Post With Nominal Length Of 07 To 12 M, Laying Of Concrete/Steel/Fiberglass Post With Nominal Length Of Up To 06 M, Led Bar 18W/48V - 3000K, Led Bar 36W/48V - 3000K, Led Bar 60W/48V - 3000K, Led Bar 9W/48V - 3000K, Anti-Sway Arm 15Kv, Arm With Suspension Clamp, Type L Arm 15 Kv, Bushing In Aluminum, Head For Power Line Entry For Conduit, In Aluminum Alloy With Anti-Corrosive Finish, With Fixation By 360 Degree Smooth Fitting, Aluminum Cable 0. 6/1Kv Multiple-Xed 3X1x70 +70Mm², Bare Aluminum Cable Without Steel Core Ca, 2 Awg - Iris, Covered Copper Cable 16.0Mm2 15Kv Xlpe, Covered Copper Cable 35, Flexible Copper Cable 3 Installation., Flame Retardant 450/750 V, For Terminal Circuits - Supply And Installation. Af_03/2023, 120 Mm², 6/1, 0 Kv, For Overhead Low Voltage Electricity Distribution Network - Supply And Installation. Af_07/2020, 16 Mm², For Terminal Circuits - Supply And Installation, 2, For Terminal Circuits - Supply And Installation. Af_03/2023, 25 Mm², For Terminal Circuits - Supply And Installation, 35 Mm², 4 Mm², 6 Mm², Bare Copper Cable 10 Mm2 Medium-Hard, Bare Copper Cable 16 Mm2 Medium-Hard, Bare Copper Cable 25 Mm2 Medium-Hard, Multipolar Copper Cable, Flexi-Vel, Class 4 Or 5, Hepr Insulation, Pvc-St2 Cover, Bwf-B Flame Retardant, 3 Conductors Of 2.5 Mm2, Protected Cable 15Kv 35Mm², Registration Of Ip Points, Rectangular Electric Buried Box, In Pre-Molded Concrete, Bottom With Crushed, Internal Dimensions: 0, 3X0. Circuit Breaker (Standard From Local Concessionaire), Base Fuse Switch ´C´ For 15 Kv/200 A, With Breaking Capacity Up To 10 Ka - With Fuse, Magnetic Control Switch In Group-Po 2 X 30A, Magnetic Control Switch In Group-Po 2 Seca De Ci-Mento/ Medium Sand/ Crushed 1) - Prepa-R
|