|
Provision Of Certain Sanction Work At (Phase-Xi) Of Various Units At Misa Camp Under Ge (S) Tezpur- 1 Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roofcoverings complete all as specified and directed 2 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed. 3 Dismantling framed work timber scantlingsas in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm insection complete all as directed. 4 Demolition of reed, lathing, single or double, including battens and plaster or chiken wire lathing and RCC jafari/jailies complete all as specified and directed. 5 Demolition of brick work built in cement mortor including all quoins, arches, pillars etc and all as specified . 6 Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed 7 Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. 8 Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. 9 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 10 Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed 11 Excavating in post holes (or similar holes)in soft/loose soil, each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed. 12 M & L for PCC (1:3:6) type C-2 using40mm graded stone aggregate as in foundation and mass concrete in post holes complete all as specified and directed. 13 M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified & as directed. 14 M&L for brickwork with subclass‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. 15 M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed 16 M & L for reinforced cement concrete Nominal Mix M-25 (1:1:2) as in columns, pillarspiers, posts & struts etc complete all as specified and directed.Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ. 17 M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips,complete all as specified and directed. 18 M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 19 M&L for rendering 15 mm thick onfaces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cementcomplete all as specified and directed. 20 M&L for 15 mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm & 5mm)seperately mixed with water proofing compound in top layer as per manufacturer"s instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. 21 Supply only liquid water proofing compound complete all as specified and directed. 22 M & L for preparation of newly plastered surfaces of wall and applying twocoatsof oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed. 23 M & L for complete removal of existing treatment and applying twocoatsof oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed. 24 M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coatof exterior primer applied @ 2.20 kg/10 sqm) overa coat of 1 mm thick wall care puttysuitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. 25 M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coatof exterior primer applied @ 2.20 kg/10 sqm) overa coat of 1 mm thick wall care puttysuitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint including complete removal of existing treatment on wall/ roof projections including facia,cornices etc by scrapping to make surface clean,free from dust,loose paint etc by skilled labour complete all as specified and directed. 26 S & F 125mmx60mm size and 1.60 mm thick pressed steel frames for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc including applying a coat of tar in inner surface ,red oxide to outer surface and filling the frame using PCC M-10 using 12.50 mm graded stone aggregate complete all asdirected. 27 M&L for PCC (1:3:6) type C1 20mm graded aggregate as in padding ,holdfast/filling of chowkhats or similar work complete all as specified and directed. 28 S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete and size of member of shutters as specified in SSR Part-I (2009) section 8 all complete all as specified and directed. 29 S & F factory made steel windows including box type hinges with steel handles & steel pag stay complete (without glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed. 30 S & F factory made steel windows with side hung shutters including box type hinges with steel handles & steel pag stay complete (with glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed. 31 M & L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed. 32 S & F instainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed 33 M & L for 3 mm thick sheet glass ordinary qualityand glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed. 34 S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed. 35 S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed. 36 S & F of 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 37 S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed. 38 S&F of floor door stopper 140mm (overall length of cover plate) of aluminum alloy body and tongue, anodized, with hard drawn steel spring fixed in floor including taking down the old one complete all as directed. 39 M&L for preparation of new wooden surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat ofprimer complete all as directed. 40 S & F of powder coated mild steel drapery rod of 20 mm inner diaof approved colour with and including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends fixed with PVC rawl plug and steel screws on walls/beam, complete all as directed. 41 M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base to floors/paths/paving/hardstanding finishing cement concrete surface even and fair without using extra cement complete all as specified and directed. 42 M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed. 43 M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado/skirting completeall as specified and directed. 44 M&L 16-18 mm thick pre-polished Kota stone slab area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm,as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed. 45 M&L 16-18 mm thick pre-polished Kota stone slab area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm,as in skirting over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed. 46 M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W(Gde E-250) quality "A" complete all as specifed and directed. 47 S & F structural rolled mild steel confirming to Fe 410-W(Gde E-250) quality "A" as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including necessary machinery for upto 10m height structure complete in all respect as specified and directed. 48 M&L for preparation of steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide primer complete all as specified and directed 49 S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. 50 S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. 51 S & F of hangers 6mm dia GI (upto 1200 mm length ) adjusting level fixed to roof slabs or steel framed structure or truss by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed 52 S & F of GI powder coated snap grid frame work for false ceiling all as specified size of grid 605x605mm with GI angle 25x25x1.5mm, main "T" of 38x25x1.5mm and secondary "T" 25x25x1.2mm complete all as directed. 53 M & L for 4mm thick non asbestos fibre cement building boards, fixed or laid/inserted to timber /GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified & directed. 54 M&L 75 mm thick Cement concrete type C2 1:3:6 (using 20 mm graded stone aggregate)as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) andfinished cement concrete surface even and smooth without using extra cement and providing joints throughout thickness of plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and two parts of sand by weight complete all as specified and as directed. 55 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed 56 Dismantling plain or corrugated steel sheeting/galvalume sheet any guage, thickness including Nainital or similar pattern roof covering,complete all as specified and directed 57 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed 58 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed. 59 M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as directed. 60 M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and directed 61 M & L for reinforced cement concrete Design Mix M-25 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ. 62 M&L for reinforced cement concrete Design Mix M-25 as in beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed.Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ. 63 M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified & as directed. 64 M&L for brickwork with subclass‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. 65 M&L for 20 mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm & 10mm)seperately mixed with water proofing compound in top layer as per manufacturer"s instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. 66 M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat including a coat of 1 mm thick wall care puttysuitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. 67 M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat including a coat of 1 mm thick wall care puttysuitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint including complete removal of existing treatment on wall/ roof projections including facia,cornices etc by scrapping to make surface clean,free from dust,loose paint etc by skilled labour complete all as specified and directed. 68 M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe 410-W(Gde E-250) quality "A" complete all as specifed and directed. 69 M&L for preparation of steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide primer complete all as specified and directed 70 S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. 71 S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. 72 S & F of hangers 6mm dia GI (upto 1200 mm length ) adjusting level fixed to roof slabs or steel framed structure or truss by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed 73 S & F of GI powder coated snap grid frame work for false ceiling all as specified size of grid 605x605mm with GI angle 25x25x1.5mm, main "T" of 38x25x1.5mm and secondary "T" 25x25x1.2mm complete all as directed. 74 M & L for 4mm thick non asbestos fibre cement building boards, fixed or laid/inserted to timber /GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified & directed. 75 S & F of30mm thick2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed. 76 S & F of mild steel 300mm, ordinary rat tail rod pattern spring including roller and roller plate welded to mild steel frame complete all as specified and directed. 77 S & F of powder coated mild steel drapery rod of 20 mm inner dia (in lengths as width of door and windows approx 1.2 m length) of approved colour with and including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends fixed with PVC rawl plug and steel screws on walls/beam, complete all as directed. 78 M & L for screed bed or bedding layer of mortar, 20mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed. 79 M & L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado/skirting completeall as specified and directed. 80 M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed. 81 M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed. 82 M&L 75 mm thick Cement concrete type C2 1:3:6 (using 20 mm graded stone aggregate)as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) andfinished cement concrete surface even and smooth without using extra cement and providing joints throughout thickness of plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and two parts of sand by weight complete all as specified and as directed. 83 M&L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed. 84 M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base to floors/paths/paving/hardstanding finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. 85 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compactedbed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. 86 M & L for cement concrete type B0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) as in copings and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of formwork (straight or curved) all exposed surface of concrete finished fair, complete all as specified and directed. 87 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. 88 M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including modular GI boxes of suitable sizesincluding 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). 89 All as per item No. 115 here-in-before but one 3 pin 5 ampsswitch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. 90 All as per item No. 115 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. 91 M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). 92 S&FModular type switch6 Amps 230V AC single module one way complete all as specified and as directed. 93 S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 94 S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 95 S&FModular type switch16 Amps 230V AC single module one way complete all as specified and as directed. 96 S&FCeiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed. 97 S&F Modular type fan regulator Step type,100 Watt, one module/ two module, 230V AC complete all as specified and as directed. 98 Supply and fixing modular white cover plate with frame 2 modules complete all as specified and as directed. 99 Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. 100 Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed. 101 Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. 102 Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed. 103 Supply and fixed 18 W LED light fitting wall mounted batten 4"ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed. 104 Supply and fixed security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. 105 Supply and fixed recessed mounted 2" x 2 " LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed. 106 Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. 107 Supply and fixed in repairsMCB SP,6 to 32 Amps, "C" series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. 108 Supply and fixed in repairs MCB TPN 63 Amps,"C" series 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 109 Taking down of AC ceiling / exhaust fan of any sweep & any height and opening the fan and oiling, greasing andreplacementofunserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and hanging it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge. 110 Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI "lightgrade" pipe from upper end of earth plate upto equipments,20 dia bore GI pipe "light grade" as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. 111 Supply, laying / fixing / connecting, testing and commissioning of 16 Sqmm x 4.0 coreLT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge 112 Supply and fixing all in one LED Solar power street light fitting of capacity 15 Watt including GI pole of 63 mm dia of height 6 meters made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body, automatically control the dimming and brightness of light, installation includes excavation, removal of old unserviceable solar street lights, and PCC foundation of the pole complete all as specified and directed 113 NOTES:1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
|