|
Universal Clamp For Box Cn-1. Copel Standard. Must Come With Screws For Fixing., Adapter (T) Type Benjamin. 2P+T Inputs. 10 Amps. Certified By Inmetro., Preformed Handle For Extension 16Mm., Water Pump Type Pliers, 10 Inches (Approx. 250Mm), With Insulated Cable And Tested For 1000 Volts (Ac) Or More. Must Meet Safety Standards, Professional Crimping Pliers (Terminal Press), Self-Adjusting Or With Ratchet, For Crimping Eyelet/Tubular Type Terminals, With Capacity From 1.5Mm To 10Mm, 17/12/2025 - 10:47:57, Heavy Rex Frame 1X1, Composed Of Galvanized Steel Sheet, In U Shape, With Pin And Cotter Pin For Insulator Installation, ½ Inch Zinc Plated Flat Washer, 1 Inch Zinc Plated Flat Washer, 5/8 Square Washer, Threaded Rod Bar, 3/8 Inch Diameter, Coarse Thread (Unc), With Standard Length Of 1 Meter. Material: Carbon Steel With Zinc Finish (Or Other Type Of Finish For Protection Against Oxidation)., Diameter 5/8 Inch, Carrying Bag For Tools, With A Minimum Dimension Of 16 Inches. Made From High-Resistance Fabric (Canvas/Polyester), With A Waterproof Or Rubberized And Reinforced Base. Must Contain Reinforced Hand Strap And Shoulder Strap, In Addition To Multiple Internal And External Pockets For Organization., Kit Containing Bushing And Washer For Conduit. Made Of Flame-Retardant Pvc (Polyvinyl Chloride), For Use In 1 ¼ Inch Conduits. The Bushing Must Be Bulged Type At The Internal End To Protect The Conductors., For Use In 1 Inch Conduits. The Bushing Must Be Bulged Type At The Internal End To Protect The Conductors., Pvc Head - 1 Inch, Pvc Head - 1, 1/4 Inch., Pvc Head - 1 And 1/2 Inch, 16Mm Insulated Duplex Aluminum Cable - 100M Roll, 25Mm Insulated Duplex Aluminum Cable - 100M Roll, 35Mm Insulated Duplex Aluminum Cable - 100M Roll, 100M Insulated Quadruplex Aluminum Cable, 25Mm - 100M Roll, 35Mm - 100M Roll, 16Mm Insulated Triplex Aluminum Cable - 100M Roll, 25Mm Insulated Triplex Aluminum Cable - Roll 100M., 35Mm Insulated Triplex Aluminum Cable - 100M Roll., Flexible Copper Cable. 16Mm. 1Kv. 100 Meters. It Can Be Blue, Yellow Or Red, As Requested., Bare Copper Conductor Cable (Without Insulation), For Application In Grounding And Spda Systems. Nominal Section Of 16 Mm2 (Forty-Six Square Millimeters), With Class 2A Stranding (7 Solid Wires) Or Similar, Complying With Standard Nbr 5349, Three-Polar Power Splitter Cable (Type Y). Designed To Divide One Power Output Into Two, Being Ideal For Connection To Ups, Pdus Or Strips With C14 Connection. The Cable Must Have One Iec 60320 C14 Male Plug On The Input End And Two Iec 60320 C13 Female Connectors On The Output Ends (The Y Fork). The Cable Length Must Be A Minimum Of 0.5 Meters (Between C14 And The Start Of The Division). The Wiring Must Have A Minimum Section Of 3 Roll With 100 Meters, 750V. May Be Blue, 10Mm Copper Flexible Cable, 100 Meter Roll, Yellow, Green Or Red, 2.5Mm Copper Flexible Cable, 4Mm Copper Flexible Cable, 6Mm Copper Flexible Cable, 2X4 Parallel Cable, 0Mm. 100 Meters. Black., Parallel Cable, 2X2, 5Mm, 100 Meters. Black., Flexible Pp Cable 2 Ways 1.5 Mm² - Roll 100 M, Flexible Pp Cable 2 Ways X 2.5
|