|
Open Shed To Support Production (Carpentry, Armature Center, Workshop, Etc.) With Scissors, 4Mm Tile, Floor In Unpolluted Concrete, Easel Kit For Water Measurement - Individual Entry, In Cpvc Dn 28 Mm (1), For 1 Meter - Supply And Installation (Exclusive Hydrometer). Af_03/2024, Supply And Installation Of Workplate With Galvanized Sheet And Wooden Structure. Af_03/2022_Ps, Siding With Metallic Tile. Af_03/2024, 17/12/2025 - 10:59:11, 17/12/2025 - 10:59:13, Junior Civil Engineer With Additional Charges, Conventional Lease Of Work, Using Template Of Pointed Running Boards Every 2.00M - 2 Uses. Af_03/2024, Mechanized Trench Excavation With Prof. Up To 1.5 M (Average Upstream And Downstream/One Composition Per Section), Backexcavation. (0.26 M3), Width. From 0.8 M To 1.5 M, On 1St Category Soil, In Locations With A High Level Of Interference. Af_09/2024, Ballast With Granular Material (Crushed Stone N.1 And Crushed Stone N.2), Applied On Floors Or Slabs On The Ground, Thickness Of 10 Cm. Af_01/2024, Manufacture, Assembly And Disassembly Of Formwork For Crowning Block, In Sawn Wood, E25 Mm, 4 Uses. Af_01/2024, Block Frame Using 5 Mm Ca-60 Steel - Assembly. Af_01/2024, Block Frame Using 6.3 Mm Ca-50 Steel - Assembly. Af_01/2024, Block Frame Using 8 Mm Ca-50 Steel - Assembly. Af_01/2024, Block Frame Using 10 Mm Ca-50 Steel - Assembly. Af_01/2024, Block Frame, Insulated Footing, Baldrame Beam And Running Footing Using 12.5 Mm Ca-50 Steel - Assembly. Af_01/2024, Baldrame Beam And Running Shoe Using 16 Mm Ca-50 Steel - Assembly. Af_01/2024, Concreting Of Crowning Block Or Baldrame Beam, Fck 30 Mpa, Using A Pump - Laying, Densifying And Finishing. Af_01/2024, Landfill With Mechanical Compaction And Control, Acquisition Mat., Manual Backfilling Of Trenches, With Percussion Soil Compactor. Af_08/2023, Surface Waterproofing With Asphalt Emulsion, 2 Coats. Af_09/2023, Technological Control Of Concrete - By Rupture Of The Test Body, Assembly And Disassembly Of Rectangular Pillar Formwork And Similar Structures, Simple Right Foot, Made Of Resin Plywood Sheet, 6 Uses. Af_09/2020, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 10.0 Mm Ca-50 Steel - Assembly. Af_06/2022, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 12.5 Mm Ca-50 Steel - Assembly. Af_06/2022, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 16 Ca-50 Steel, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using Ca-60 5 Steel, Concrete Fck 30Mpa, Ratio 1:2, 1:2, 5 (In Dry Mass Of Cement/Medium Sand/Gravel 1) - Mechanical Preparation With Concrete Mixer 600 L. Af_05/2021, Assembly And Disassembly Of Beam Formwork, Metal Shoring, Made Of Resin Wood Sheet, Pillar Frame Or Beam Of Conventional Reinforced Concrete Structure Using 6.3 Mm Ca-50 Steel - Assembly. Af_06/2022, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using Ca-50 Steel Of 8, Prefabricated Lattice Slab For Floor Or Roof, Interaxis 38Cm, H12cm, El. Filling In Eps H8cm, Including Wooden Shoring And Capping 4Cm., H16cm, El. Filling In Eps H12cm, H21cm, El. Filling In Eps H16cm, Execution Of Radier, 20 Cm Thick, Using Forms In Sawn Wood. Af_09/2021, Ceramic Brick Masonry
|