Glucose Set Of Biochemical Reagents From The Set Biochemical-Turbidimetric Analyzer Ba400, Manufactured By Biosystems S.A (Spain), Rk-Mt-5 No. 021111, The Presence Of A Barcode On Each Bottle. Diabetic Profile; Glucose Oxidase Endpoint; Liquid Monoreagent. Composition: Reagent A. Phosphate 100 Mmol/L, Phenol 5 Mmol/L, Glucose Oxidase > 10 U/Ml, Peroxidase > 1 U/Ml, 4-Aminoantipyrine 0.4 Mmol/L, Ph 7.5. Metrological Characteristics: Detection Limit: 2.8 Mg/Dl = 0.155 Mmol/L. Linearity Limit: 500 Mg/Dl = 27.5 Mmol/L. Accuracy: Average Concentration: 88 Mg/Dl = 4.90 Mmol/L. Repeatability (Cv):1.0%. Intralaboratory Rate (Cv): 1.7%. Average Concentration: 220 Mg/Dl = 12.2 Mmol/L Repeatability (Cv): 0.4%. Intralaboratory Rate (Cv): 1.1%. Number Of Studies -1800. Packaging 10X 60Ml, T+2 +8 C. Reagents Must Be Recommended For Use By The Manufacturer Of The Ba200/Ba400 Analyzers., Urea Set Of Biochemical Reagents From The Kit Biochemical-Turbidimetric Analyzer Ba400, Manufactured By Biosystems S.A (Spain), The Presence Of A Barcode On Each Bottle. Renal Profile; Urease/Glutamate Dehydrogenase, Fixed Time; Liquid Bireagent. Composition: Reagent A. Tris 100 Mmol/L, 2-Oxoglutarate 5.6 Mmol/L, Urease > 140 U/Ml, Glutamate Dehydrogenase > 140 U/Ml, Ethylene Glycol 220 G/L, Sodium Azide 0.95 G/L, Ph 8.0. Reagent B. Nadh 1.5 Mmol/L, Sodium Azide 9.5 G/L. Metrological Characteristics: Threshold Sensitivity: 3.69 Mg/Dl = 1.72 Mg/Dl Bun = 0.614 Mmol/L. Linearity Limits: 300 Mg/Dl = 140 Mg/Dl Bun = 50 Mmol/L. Accuracy: Serum Average Concentration: 26.8 Mg/Dl = 4.47 Mmol/L. Repeatability (Cv): 3.5%. Intralaboratory Rate (Cv): 5.0%. Average Concentration: 137 Mg/Dl = 22.9 Mmol/L. Repeatability (Cv): 1.1% Within-Laboratory Rate (Cv): 1.7%. Urine Average Concentration: 1291 Mg/Dl = 215 Mmol/L. Repeatability (Cv): 3.1% Within-Laboratory Rate (Cv): 4.3%. Average Concentration: 1771 Mg/Dl = 295 Mmol/L. Repeatability (Cv): 2.9% Within-Laboratory Rate (Cv): 3.1%. The Number Of Studies Is 1800. Packaging 8X60+8X15ml, T+2 +8 C. Reagents Must Be Recommended For Use By The Manufacturer Of The Ba200/Ba400 Analyzers., Lysis Solution (Lyse) For Hematology Analyzers Of The Swelab Alfa Plus Series. Kit Contents: 1 X 5 L (At Least 900 Analysis Cycles), Isotonic Solution For Hematology Analyzers Of The Swelab Alfa Plus Series. Kit Contents: 1 X 20 L (At Least 900 Analysis Cycles)
Contact Information
Contact Person
КОПЫТИН МАКСИМ ВЛАДИМИРОВИЧ
Address
595830100, 150300, Казахстан, г. Смирново, ул. Молодежная, д. 6, оф.
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 106406650
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.