|
Bids Are Invited For 1 CABLE 1.1KV,4 CORE,1O SQMM, SECTOR SHAPED STRANDED ANNEALED COPPER CONDUCTOR, CONDUCTOR INSULATION-XLPE (COLOUR - RED, YELLOW, BLUE, BLACK), INNER AND OUTER SHEATH. FRLS EXTRUDED PVC :ST2 (COLOUR - BLACK), ARMOURGALVANISE STEEL STRIP, CABLE SHALL BE CONFIRMING TO lS: 7098 (PART{)/198,PACKING : SINGLE LENGTH ON NON-RFTURNABLE DRUM VARIATION lN LENGTH: rZ%MAX lN TOTAL LENGTH RT CERTIFICATE: MANUFACIURER'S ROUTINE TEST CERTIFICATE SHALL BE FURNISHED AT THE TIME OF SUPPLY MARKING / EMBOSSING: SEQUENTIAL LENGTH MARKING, EMBOSSING OF CABLE SIZE, MFGR'S NAME, VOLTAGE GRADE, YEAR OF MFGR AT REGULAR INTERVAL, 300147897 1,000 Meter 2 POWER CABLE, FRLS EXTRUDED PVC ST2 INSULATED, PVC SHEATHED. GI FLAT/ROUND ARMOURED STRANDED COPPER CONDUCTOR, SIZE-16 SQ.MM, NO OF CORES-4, VOLT.GRADE- LT 1.1KV, CONFIRMING TO IS:1554 Part(I). AS PER ATTACHED SPECIFICATIONS 300120585 1,000 Meter 3 4C X 4 SQ MM COPPER ARMOURED CABLE XLPE INSULATED,EXTRUDED ST2 PVC INNER SHEATHED, GALVANISED ROUND STEEL WIRE ARMOURED AND OVERALL PVC SHEATHED LT 1.1 KV GRADE, COMF. TO IS: 7098(I), 300111514 1,000 Meter 4 SUPPLY OF ARMOURED, C2-FR-LSH, XLPE INSULATED, 1.1 KV GRADE, 4 CORE, 2.5 SQMM, COPPER CONDUCTOR CABLE AS PER THE FOLLOWING SPECIFICATIONS/REQUIREMENTS: 1. AS PER STANDARD – BIS, IS 7098 (PART 1): 1988, IS 5831, IS 8130, UP TO LATEST REVISIONS 2. IMPROVED FIRE PERFORMANCE CATEGORY - FRLS 3. VOLTAGE-1.1KV 4. MATERIAL OF CONDUCTOR - COPPER 5. CONSTRUCTION OF CONDUCTOR – STRANDED 6. TYPE OF INNER SHEATH – PVC-ST2, EXTRUDED. PVC WRAPPED INNER SHEATH IS NOT ACCEPTABLE 7. TYPE OF CABLE – ARMOURED 8. MATERIAL OF ARMOURING – GALVANIZED ROUND STEEL WIRE 9. TYPE OF ARMOURING – SINGLE 10. TYPE OF OUTER SHEATH – PVC-ST2, FRLS, EXTRUDED. 11. COLOUR OF OUTER SHEATH – BLACK 12. NOMINAL CONDUCTOR CROSS SECTIONAL AREA – 2.5 SQMM 13. NUMBER OF CORES - 4 14. AVAILABILITY TYPE TEST REPORT – YES. FAT AND ALL ROUTINE TESTING AS PER IS 7098 (PART 1): 1988, UP TO LATEST REVISIONS SHALL BE WITNESSED BY RCF REPRESENTATIVE BEFORE DISPATCH CLEARANCE. 300128339 1,000 Meter 5 TECHNICAL SPECIFICATION: - 4 CORE X 6 MM2 1.1 KV copper CABLE. 1) VOLTAGE GRADE: 1100 VOLTS. 2) CONDUCTOR: COPPER. 3) NOMINAL SIZE OF CONDUCTOR: 6 SQUARE MM. 4) NUMBER OF CORES: 4 CORE 5) NUMBER OF CORES: 4 CORE. 6) NOMINAL INSULATION THICKNESS: 0.7 MM. 7) INNER SHEATH: EXTRUDED PVC TYPE ST-2. 8) MINIMUM INNER SHEATH THICKNESS – 0.3 MM. 9) OUTER SHEATH: EXTRUDED PVC FRLS TYPE. 300133475 1,000 Meter 10) MINIMUM OUTER SHEATH THICKNESS: – 1.24 MM. 11) ARMOUR TYPE: GALVANIZED STEEL. 12) NOMINAL DIA OF ARMOUR (MM): As per latest standards. 13) INDIAN STANDARD: IS 7098, IS 5831, IS 8130; UP TO LATEST STANDARD. GENERAL SPECIFICATION:- 14) ONLY POSITIVE TOLERANCE FOR LENGTH IS ACCEPTABLE 15) PVC WRAPPED INNER SHEATH IS NOT ACCEPTABLE. 16) FOLLOWING TYPE TEST CERTIFICATES SHALL BE PROVIDED ALONG WITH OFFER/BID. I. ANNEALING TEST II. CONDUCTOR RESISTANCE TEST III. TEST FOR ARMOUR WIRES IV. TEST OF THICKNESS OF INSULATION AND SHEATH. V. PHYSICAL TEST FOR INSULATION AND OUTER SHEATH VI. INSULATION RESISTANCE TEST VII. HIGH VOLTAGE TEST VIII. FLAMEABILITY TEST IX. HOT SET TEST 17) FOLLOWING ROUTINE TEST AND ACCEPTENCE TESTS SHALL BE CARRIED OUT (If applicable as per NIT) DURING INSPECTION PRIOR TO DISPATCH. PARTY SHALL INFORM AT LEAST 15DAYS IN ADVANCE NOTICE FOR WITNESSING ROUTINE TEST AND ACCEPTENCE TEST AT PARTY’S WORKS :- I. CONDUCTOR RESISTANCE TEST II. ANNEALING TEST III. TEST OF THICKNESS OF INSULATION AND SHEATH IV. HIGH VOLTAGE TEST V. INSULATION RESISTANCE TEST VI. TENSILE STRENGTH AND ELONGATION AT BREAK TEST FOR INSULATION AND SHEATH 18) CABLE SHALL BE WOUND ON NON RETURNABLE METALLIC DRUM. 19) LENGTH OF CABLE SHALL BE MARKED AT EVERY METER INTERVAL. 20) CABLE SHALL BE EMBOSED WITH FOLLOWING I. MAKE: II. MONTH & YEAR OF MANUFACTURING: (NOTE: SHOULD NOT BE EARLIER THAN DATE OF P.O.) Total Quantity : 5000
|