Bids Are Invited For C73340415174 Supply Of High Static Pressure Ductable Ac Unit Capacity 8Point5 Tr Having One Indoor And One Out Door Unit Refer Annexure-Iii - Supply Of High Static Pressure Ductable Ac Unit Capacity 8Point5 Tr Having One Indoor And One Out Door Unit Refer Annexure-Iii , 100000000000 Supply Of Suitable Size Refrigerant Grade Copper Piping Between Indoor And Outdoor Units Of Ductable Split Ac Units 8Point5 Tr Refer Annexure-Iii - Supply Of Suitable Size Refrigerant Grade Copper Piping Between Indoor And Outdoor Units Of Ductable Split Ac Units 8Point5 Tr Refer Annexure-Iii , 100000000001 Providing Cpvc Sdr11 Pipes 32 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation For Condensate Water Drain From The Ac Indoor Refer Annexure-Iii - Providing Cpvc Sdr11 Pipes 32 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation For Condensate Water Drain From The Ac Indoor Refer Annexure-Iii , 100000000002 Providing Of Cpvc Sdr11 Pipes 25 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation For Condensate Water Drain Refer Annexure-Iii - Providing Of Cpvc Sdr11 Pipes 25 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation For Condensate Water Drain Refer Annexure-Iii , 100000000003 Supplying Of Xlpe Insulated, Pvc Sheathed, Armoured, Copper Conductor, 1Point1 Kv Grade Lt Cable Of Size 4 Core - 6 Sqmm Refer Annexure-Iii - Supplying Of Xlpe Insulated, Pvc Sheathed, Armoured, Copper Conductor, 1Point1 Kv Grade Lt Cable Of Size 4 Core - 6 Sqmm Refer Annexure-Iii , 100000000004 Supply Of Xlpe Insulated, Pvc Sheathe, Copper Conductor, 1Point1 Kv Grade Lt Cable Of Size 4 Core - 2Point5 Sqmm Refer Annexure-Iii - Supply Of Xlpe Insulated, Pvc Sheathe, Copper Conductor, 1Point1 Kv Grade Lt Cable Of Size 4 Core - 2Point5 Sqmm Refer Annexure-Iii , 100000000005 Supply Of 150 Mm Width X 50 Mm Depth X 1Point6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray Refer Annexure-Iii - Supply Of 150 Mm Width X 50 Mm Depth X 1Point6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray Refer Annexure-Iii , 100000000006 Installation Testing And Commissioning Of High Static Pressure Ductable Ac Unit Capacity 8Point5 Tr Refer Annexure-Iv - Installation Testing And Commissioning Of High Static Pressure Ductable Ac Unit Capacity 8Point5 Tr Refer Annexure-Iv , 100000000007 Erection Testing And Commissioning Of Suitable Size Refrigerant Grade Copper Piping Between Indoor And Outdoor Units Refer Annexure-Iv - Erection Testing And Commissioning Of Suitable Size Refrigerant Grade Copper Piping Between Indoor And Outdoor Units Refer Annexure-Iv , 100000000008 Laying Of Cpvc Sdr11 Pipes 32 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation For Condensate Water Drain Refer Annexure-Iv - Laying Of Cpvc Sdr11 Pipes 32 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation For Condensate Water Drain Refer Annexure-Iv , 100000000009 Laying Of Cpvc Sdr11 Pipes 25 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation Refer Annexure-Iv - Laying Of Cpvc Sdr11 Pipes 25 Mm With 9 Mm Thick Tube Type Nitrile Rubber Insulation Refer Annexure-Iv , 100000000010 Laying Of Xlpe Insulated, Pvc Sheathed, Armoured, Copper Conductor 1Point1 Kv Grade Lt Cable Of Size 4 Core - 6 Sq Mm Refer Annexure-Iv - Laying Of Xlpe Insulated, Pvc Sheathed, Armoured, Copper Conductor 1Point1 Kv Grade Lt Cable Of Size 4 Core - 6 Sq Mm Refer Annexure-Iv , 100000000011 Laying Of Xlpe Insulated, Pvc Sheathe, Copper Conductor 1Point1 Kv Grade Lt Cable Of Size 4 Core - 2Point5 Sqmm Refer Annexure-Iv - Laying Of Xlpe Insulated, Pvc Sheathe, Copper Conductor 1Point1 Kv Grade Lt Cable Of Size 4 Core - 2Point5 Sqmm Refer Annexure-Iv , 100000000012 Installation Of 150 Mm Width X 50 Mm Depth X 1Point6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray Refer Annexure-Iv - Installation Of 150 Mm Width X 50 Mm Depth X 1Point6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray Refer Annexure-Iv , 100000000013 Dismantling And Shifting Of Existing Ductable Indoor And Outdoor 2 X8point5 Tr Refer Annexure-Iv - Dismantling And Shifting Of Existing Ductable Indoor And Outdoor 2 X8point5 Tr Refer Annexure-Iv Total Quantity : 425
|