Bids Are invited for Visual Inspection - Visual Inspection And Photography Performing A Visual Survey Of The ... in India
Tender Notice
TenderID
106379464
Tender Brief
Bids Are invited for Visual Inspection - Visual Inspection And Photography Performing A Visual Survey Of The Building And Recording/Maping On Drawing To Assess Extent Of Spelled Concrete, Cracked Concrete,Honey Combing, Reinfocement Corrosion, Delami
Bids Are invited for Visual Inspection - Visual Inspection And Photography Performing A Visual Survey Of The Building And Recording/Maping On Drawing To Assess Extent Of Spelled Concrete, Cracked Concrete,Honey Combing, Reinfocement Corrosion, Delaminated Concrete Etc, Taking Photographs And Videos To Collect Evidence Of Damage To Structure. , Ultrasonic Pulse Velocity Test - Ultrasonic Pulse Velocity Test For Rcc Structure In Accordance With Is 516 Part-5 2018 Section 1 By Portable Ultrasonic Non Destructive Digital Test Equipment Including Chipping Out Plaster , Rebound Hammer Test - Rebound Hammer Test In Accordance With Is 516 Part-5 2018 Section 4 By Portable Rebound Hammer Equipment In Strategic Locations. , Core Test - Core Cutting And Compression Test For Rcc Structure In Accordance With Is 516 On Rcc Members. 70 Mm Core Cutting In Reinforcement Concrete, Core Filling By Speialized Epoxy Material/Micro Concrete With Bond Coat At Strategic Locations. , Reinforcement Mapping - Reinforcement Mapping Test On Rcc Members To Assess Covers, Spacing Of Bars Including Approximate Diameter Strategic Locations. , Chemical Test - Chemical Test For Rcc Structure In Accordance With Is 456 2000 Using Ready Made Kits And Reagents. Sample Collected Will Be From Half Cell/Carbonation Powder. (I) Determination Of Ph Value. (Ii) Determination Of Water Soluble Sulphates. (Iii) Determination Of Water Soluble Chlorides Contents Strategic Locations. , Half Cell Potential Test - Half Cell Potential Test For Rcc Structure In Accordance With Is 516 Part-5 2018 Section 2 Half Cell Potential To Assess The Probability Of Corrosion Of Reinforcement At Strategiclocations.. , Carbonation Test - Carbonation Test For Rcc Structure In Accordance With Is 516 Part-5 2018 Section 3 Corbonation Test To Measure Extent Of Carbonation From The Concrete Surface At Strategiclocations. , Consultancy Services For - To Check & Confirm Present Status Of Structure On Basis On Ndt Results & Visual Inspection
Contact Information
Address
Mumbai
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 106379464
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.