|
Conventional Location Of Work Using Pontaletas Running Board Jig, Manual Excavation Of Land, Trench Bottom Preparation, Manual Backfilling, Mechanized Excavation, 12/15/2025 - 10:26:37, 12/15/2025 - 10:29:36, 12/15/2025 - 10:29:43, Preparation Of The Trench Bottom With A Layer Of Crushed Stone, Cyclopean Concrete, Maneuver Loading And Unloading Of Soil And Granular Materials, Transportation Of Crushed Stone, Manufacture Of Formwork For Beams, Frame Of Beam Baldrame Block And Footing Using Steel Ca 60 Of 5Mm, Block Frame Of Beam Baldrame And Footing Using Steel Ca 50 Of 8Mm, Concreting Of Beams And Slabs, Masonry Sealing, Lintel Up To 1.5 M Span, Counter Lintel Up To 1.5 M Span, Linear Marble Sill L 15Cm, Masonry Lashing Strap, Manufacture Of Formwork For Slabs, Assembly And Dismantling Of Solid Slab Formwork, Slab Frame, Manufacture And Installation Of Entire Scissors In Wood, Manufacture And Installation Of Half Shear In Wood, Wooden Frame, Roofing With Tiles, Ridge For Tile, Flashing In Galvanized Steel Sheet Number 24, External Internal Flashing In Galvanized Steel Sheet Number 26, Surface Waterproofing With Asphalt Emulsion, Surface Waterproofing With Polymeric Mortar Acrylic Membrane, Drain Or Emerging Point Treatment, Semi Hollow Wooden Door 80 Sliding Wheel With 3 Leaves, Easel Kit For Water Measuring, Hydrometer, Water Consumption Point, Polypropylene Water Box, 40Mm Pvc Tube, 50Mm Pvc Tube For Sewer, Pvc Tube Normal Series Building Sewer Dn 75Mm., 100Mm Pvc Sewer Tube In Meter, Pvc Knee 100Mm White, Knee 90 Pvc Sewer 40Mm, Knee 45 Pvc Sewer 40Mm, Knee 90 Sewer 50Mm, Knee 45 Pvc Sewer 50Mm, Juncao Simples Pvc Serie Normal Building Sewer Dn 50X50mm, Juncao Pvc Sewer 100 50Mm, 50Mm Sewer, Siphon Box With Grid 150X150x50 50Mm Outlet, Pvc Dry Drain Dn 100 Masonry Inspection Unit, Grease Trap, Weldable 25Mm Ball Register, Float Tap For Screw-On Water Tank 1, Pressure Register 3 4, Drawer Register, Concrete Septic Tank Capacity, Sink, Single-Phase Energy Input Standard, Reinforced Concrete Post With Circular Section Extension Of 9 00M Resistance Of 200 To 300 Dan Type C 14., Concrete Post Laying, Lighting Point Electrical Box Conduit Cable Tear Break And Lead, Socket Point Inc. Socket 10A 250V Electrical Box Conduit Cable Tear Break And Lead, Socket Point Inc. Socket 20A 250V Electrical Box Conduit Cable Tear Break And Lead, Socket Point Inc. Socket Shower Electrical Box Conduit Tear Cable Breaking And Leading, Embedded Pvc Power Distribution Board, Monopolar Circuit Breaker 16 A, Bipolar Circuit Breaker 50A, Plafon Type Luminaire, Sconce Luminaire, Electric Shower, Chapisco Ci Ar 1 3 Preparation And Application, Single Putty For Receiving Paint, Chapisco, Plaster Ci Ca Ar 1 2 8, Plaster Or Single Putty, Crushed Ballast, Subfloor, Ceramic Coating, Enamelled Ceramic Coating, Ceramic Wall Coating, Ceramic Skirting, Sidewalk, Granite Threshold, Pvc Lining, R
|