Tender For Special Repair / Replacement Of Ber Cooling Appliances At Afs Hakimpet Under Ge (Af) Hakimpet.; 1 Supply, installation, fixing, testing and commissioning AC Split type, Intellisense inverter technology compressor, three star energy saving unit, single phase, cooling capacity 1.0 TR, including Remote Control unit,Plasma filter for better indoor air quality with minimum 3 star rating electric driven and split AC copper condensing unit (outdoor unit) fixed onsuitable size perforated angle iron frame for mounting condensing units as required and evaporator grouted in side room at suitable height with provision of outlet PVC pipe for draining out condensed water up to floor level and gas connection by soldering or brazing including extra copper pipe duly insulated by insulated material & gas where as required and testing after installation complete all as specified and directed. 2 Supply, installation, fixing, testing and commissioning AC Split type, Intellisense inverter technology compressor, three star energy saving unit, single phase, cooling capacity 1.5 TR, including Remote Control unit,Plasma filter for better indoor air quality with minimum 3 star rating electric driven and split AC copper condensing unit (outdoor unit) fixed onsuitable size perforated angle iron frame for mounting condensing units as required and evaporator grouted in side room at suitable height with provision of outlet PVC pipe for draining out condensed water up to floor level and gas connection by soldering or brazing including extra copper pipe duly insulated by insulated material & gas where as required and testing after installation complete all as specified and directed. 3 Supply, installation, fixing, testing and commissioning AC Split type, Intellisense inverter technology compressor, three star energy saving unit, single phase, cooling capacity 2.0 TR, including Remote Control unit,Plasma filter for better indoor air quality with minimum 3 star rating electric driven and split AC copper condensing unit (outdoor unit) fixed onsuitable size perforated angle iron frame for mounting condensing units as required and evaporator grouted in side room at suitable height with provision of outlet PVC pipe for draining out condensed water up to floor level and gas connection by soldering or brazing including extra copper pipe duly insulated by insulated material & gas where as required and testing after installation complete all as specified and directed. 4 Supply, installation, commissioning of Water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs complete all as specified and directed. 5 Supply, installation, commissioning of Water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 Ltrs complete all as specified and directed.Make : For Item No. 1 to 5 Bluestar / Daikin /Carrier /Usha / Voltas / Hitach / Lloyd 6 Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Plastic/PVC Body complete all as specified 7 Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres .BEE 5 star rated complete all as specified. 8 Supply and fix refrigerator, electric driven (single phase), capacity more than 195 Litres up to 310 Ltrs BEE 5 star rated complete all as specified.Make: Godrej / LG / Samsung/ Whirlpool / Hitachi / Voltas/ Bluestar 9 Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz, 320 Ltrs Capacity complete all as specified. 10 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed.Make : V-Guard/ Vinitec/ Volina/ Power One /Sinetrac/ Microtech/ Spectron 11 Supply, Installation, testing and commissioning of ductable AC of 8.5 TR capacity, regular ductable including replacing the piping, insulation, ducting complete all as specified and directed by Engineer-in-Charge. Model No. FDR100FRV16, Make : DAIKINor equivalent model of Blue star / Carrier / Hitachi / Voltas 12 Note: Cost of the following items are deemed to be included in quoted rates:-(a) Supply, Install , Testing and Commissioning of R 410a Refrigerant Gas charging in Ductable AC to acheive desired/ specified pressure.(b) Supply, Install , Testing and Commissioning of Copper piping with insulation and communication cable of suitable size and lenghth.(c) Canvas mouth connection for ductable Indoor unit of suitable size.(d) Supply, Install , Testing and Commissioning of 24G GI fabricated duct with supports of suitable size including suitable support.(e) Supply, Install , Testing and Commissioning of Acoustic Insulation of G.I ducting.(f) Supply, Install , Testing and Commissioning of AI powder coated continous grill with colour damper for supply air.(g) Supply, Install , Testing and Commissioning of PVC drain piping with insulation and supports.(f) Supply, Install , Testing and Commissioning of ductable AC of 8.5 TR capacity complete all as specified and directed by Engineer-in-Charge.
|