Tender For Removing Refrigerant From Existing Units Thereby Disconnecting The Units, Existing Piping, Existi ... in India
Tender Notice
TenderID
106185440
Tender Brief
Tender For Removing Refrigerant From Existing Units Thereby Disconnecting The Units, Existing Piping, Existing Ducting, Electrical Wiring,Drainage System Of Machines, Dismantling Of Existing Ducting Connections And Then Shifting Of Machines In Place/
Tender for Removing Refrigerant From Existing Units Thereby Disconnecting The Units, Existing Piping, Existing Ducting, Electrical Wiring,Drainage System Of Machines, Dismantling Of Existing Ducting Connections And Then Shifting Of Machines In Place/Position To Newly Constructed Roomsas Per Direction Of Engineer-In-Charge And Site Requirement. , Repair To Package Machines Wherever Required During Shifting Including Cleaning To Coils, Repair To Machine Panel Including Damaged Wiring, Repair To Refrigerant Piping Of Machines Including Ht Hp Side And Lt Lp Side Etc. , Installation Of Existing Units In Plant Room With Resisto Flex Sheet /Damping Absorbentpad (Water Resistant) Under Unitsas Per Direction Of Engineer-In-Charge And Site Requirement , Re-Installation Of Old Electrical Panels After Necessary Repairs Along With Cabling, Heaters, Wiring, Avr In New Plant Rooms After Dismantling From The Old Plant Room Along With Supply And Installation Of New Cables And Wires Of Assorted Sizes, If Required, As Per Site Requirementand Direction Of Engineer-In-Charge. , Re-Installation Of Old Refrigerant Piping For Existing Unitsalong With Allied Works Like Supply And Installation Of New Cu Refrigerant Pipes Of Assorted Sizes And Etc, If Required, As Per Site Requirementand As Per Direction Of Engineer-In-Charge. The Job Further Includes Pressure Testing For Atleast 24 Hours By Using Nitrogen, Then Vacuumising Before Filling The Refrigerant. , Re-Designing, Supply, Installation, Testing And Commissioning Of Supply Duct With Branches And Return Air Duct By Way Of Extension From Old Ductto New Plant Rooms And Modification Of Existing Duct System For Proper Flow And Return To Ward And Side Corridors Along With Allied Workslike Thermal Insulation, Insulation With 25Mm Heavy Density Nitrile Rubber Covered With Glass Cloth And Star Bond, Duct Lining With Open Cell Nitrile Rubber (25 Mm) As Per Site Requirementetc. As Per Site Requirement And Direction Of Engineer-In-Charge. 22 G , Re-
Contact Information
Contact Person
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Address
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 106185440
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.