Tender For Special Repair To Bldg No P-09 (Near Electrical Section) & T-6 At 27 Ed, Additional /Alteration Todispersal Storage Area At 13 Brd Under Ge (Af) Gurgaon No 1; 2 Dismantling of plain or corrugated steel sheeting/ AC sheeting any gauge thickness including nanital or similar pattern roof coverings all as specified and as directed. 3 Dismantling of existing mild steel work of any description or in any location complete all as specified and directed by Engr-in-charge. 4 Dismantling of brick work built in cement morat including all qiuions arches, pillara etc complete all as specified and as directed 5 M&L forbrick work with sub class B bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-charge 6 M&L for RCC (Nominal mix) type B1, 1:1 1/2:3 (20 mm graded aggregated) asin slab supported walls, beams and columns in floors, roof, landing, balconies, conopies, cooping deck slab and selves and the like. 7 M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engr-in-Charge. 8 -Ditto, of above item No 6 but 5mm dia and over upto and including 10mm dia and binders. 9 M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping). 10 M&L rendering 10 mm thickfare faces of brick work or concrete surfaces of roof inCM (1:4) mixed with WPC as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. 11 Supply only liquidwater proofing compound 12 Excavation in trenches nexc 1.50m wide and n exc 1.5m deep, for foundation etc.or for shafts walls,cess pits, manholes, pier holes etc.and getting out in Soft/Loose soil, complete all as specified and as directed 13 M&L for PCC 1:4:8 type D2 in fdn using 40mm graded stone aggregate as in foundation ,mass concrete ect.complete all as specified and as directed. 14 M&L for RCC1:2:4 type B1 (20 mm graded aggregate) as in footing, plinth beam,foundation,base of columns etc. basement slabs,under-reamed piles and mass concrete complete and all as specified and as directed by Engr-in charge 15 M & L for RCC 1:2:4 Type B1 (20 mm graded aggregate) as in Columns, pillars piers post and struts etc.(using 20mm graded stone aggregate) and all as specified and as directed by Engr-in-charge. 16 Formwork to sides of concrete foundation, footings, bases of columns, rafts & rafts beams, sides & soffits (if any) of foundation & plinth beams; & similar work; vertical or to batter etc for rough finished surfaces. 17 Formwork to sides of pillars, posts, struts, piers, columns & stanchions in Square, rectangle or polygonal any shapeand not exceeding 200 mm thick shelves etc for rough finished surfaces. 18 Taking down Cement Plaster from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (Note :- Rate included up to 4 th storey with scaffolding and all safety measures) 19 M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surfaces as in ceiling mixed with integral water proofing compound , the surface shall be cured and allow to dry, finished even and smooth without using extra cementcomplete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately. 20 M&L for 15 mm thick rendering in CM 1:6 on brick/concrete surfaces of wall, mixed with integral water proofing compound, the surface shall be cured and allow to dry, finished even and smooth without using extra cementcomplete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately. 21 M&L for 15 mm thick rendering in CM 1:4 on brick/concrete surfaces of wall, mixed with integral water proofing compound, the surface shall be cured and allow to dry, finished even and smooth without using extra cementcomplete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately. 22 M&L for prepration of new wall surfaces and applying two coats or more distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, by auto Roller ofrequired shade and colour complete, as per manufacturers specification including necessary (scoffolding 4th storey). 23 M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including necessary (scoffolding 4th storey). 24 M&L for preparation of newely plastered surface of ceiling and applying three coats of white wash complete and all as specified and as directed 25 Dismantling fencing wire mesh any type in any situation complete all as directed.Note : Measurement of length/width of fencing shall be measured from bottom row to tap row for payment. 26 Dismantling post or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground in natural ground. 27 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm. 28 M&L providing Cement concrete 1:3:6 Type C2 (40 mm graded aggregate) as in foundations,filling and mass concrete. 29 S&F MS Angle iron as in posts and struts ande strips in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (securing with mesh etc including all necessary drilling bolting or reveiting etc and similar works conforimng to Fe 290 (Gde-E-165 quality B. Note Post/Sttruts of angle iron made to shape shall be welded to exsisting angle iron bracket of securtity wall, contractor shall make his own arrangement for welding for boundry wall by using gen sets or any alternate arrangement. 30 S&F for MS framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, welded or forged into spikes, framed guard bars; barred iron door; ladders; framed baluster; walk ways; railing; framed work of water tank, for portions framed and hung as gates, including pintle hinges, stops hand made sliding bolts, etc and similar work conforming to Fe-290, Gde-E-165 all as specified and directed by Engr-in-charge. 31 S&F Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts including securing or type at crossings with and provision of galvanised mild steel wire staples or steel pins, etc as directed 32 S&F in repair chain link MS galvanised fencing, any size or type including line wires, any mesh, standard rails, straining bolts etc including provision of binidng wire all as specified and directed. 33 S&F950/450 mm dia concertina coil of reinforced punched (chrome rajor or blade wire) with barbed tap of 0.5 mm thick galvanised steel sheet and core wire of dia 2.5 mm high tensile steel wire incluidng galvanized MS staples/ clips for tying at crossing, complete all as specified and directed by Engineer-in-charge . 34 M&L Preparation new or previously untreated steel surface of any description, over 10 cm in width or girth, applying two coat synthetic enamel (ordinary tint) paint including over one coat of red oxide zinc chrome primerall as specified and directed by Engr-in-charge. 35 Surface excavation n .exc 30 cm deep and averaging 15 cm deep and getting out in Soft/Loose soil. 36 M&L for broken stone or boulders hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exc 100 mm thick, watered and rammed to a true surface. 37 M&L for 75mm thick cement concrete 1:4:8 type D-2 using (40mm graded stone aggregate ) as in sub base of floor path and hard standing complete all as specified and directed. 38 M&L for 75 mm thick cement concrete 1:2:4 type B-2, (using 20 mm crushed and graded stone aggregate) on path, complete in all respect as specified and directed. 39 M&L Chequred cement concrete tiles 30 cm x 30 cm x 30 mm thick set and jointed and pointed in neat cement slurry with grey cement and pigment in floors including 20 mm screed bed in CM 1:6complete all as specified. 40 M&L for PCC 75 mm thick type C2, 1:3:6 using (40 mm graded aggregate ) asin plinth protectionpath finished even and smooth without using extra cement. 41 Returning filling in incl spreading, levelling, watering , well ramming in layers n. exc 25 cm in layers etc all as specified & directed. 42 Removing excavated material from MOD land exc. 5 km and up to 15 km and depositing where directed 43 Dismantling of Existing roof andwall coverings,brick tiles or terrincing tiles,single layer on roof parapet,including cleaning serviceable , complete all as specified by Engineer-in-Charge 44 Cleaning top surfaces andwire brushing, lime terracing or cement concrete, cutting or uprooting grass on old mud phuska, removingrubbish off the premises,cleaning surface and preparing to receive new mud plstering including flashings and junction of parapets etc,and surface painting, with a layer of blown grade bitumen of any penetration applied hot@ 1.7 kg per sqm blinded with grit or pea size gravel @ 0.006 cum per sqm and lightly tampered area of flashing of roofcomplete all as specified and directed by Enginer-in-Charge 45 M&L for PCC 1:2:4 type B0 using (20mm graded stone aggregate) as in roof kerbs, side haunching or mud stops, rounded or chamfered on edges seal the joints in sunken portion, cooping with PCC blocks complete all as specified and directed by Engr in Charge. 46 M&L for 15 mm thick cement plasteringin CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with 2% water proofing compound, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge (including bldg ht up to 4rd Storey ). Note :- Water proofing compound shall be measured & paid separately.all as specified and as directed by Engineer-in-Charge 47 M&L water proofing treatment on roof and vertical surface consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm including cleaning on plaster surface all as specified.(c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.00 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 150gm/ sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions,including, applyingtwo coat Bitumenwater proofing aluminium heat resistance painton the roof as per manufacture instructions Make : PLASCON/PLASCON or equivalent. complete all as specified and directed by Engineer in Charge. 48 All as per Srl item No 8 above but except bricks (old dismantled serviceable bricks obtainedshall be reused after necessary cleaning of mortar)etc by Engineer in Charge. 49 M&L preparation of new plaster surface and applying two coats of Oil bound distemperof wall over a coat of primeronwall surfaces complete all as specified and directed by EIC. 50 M&L preparation of new plaster surface and applying two coats ofOBDof ceiling over a coat of primeronwall surfaces complete all as specified and directed by EIC. 51 M&L for Complete removal and preparation of existing treatmnet of plastered surfaces on walls applying two coats of Oil bound distemper over a coat of primer complete all as specified and directed by Engineer in Charge. 52 M&L Finishing walls with exterior Acrylicall weather emulsion paint (100% acrylic) exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of new surfaces complete all as specified and directed. 53 M&L Finishing walls with exterior Acrylicweather emulsion paint (100% acrylic) Smooth exterior paint of required shade : old work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including preparation of old surfaces complete all as specified and directed by Engineer in Charge. 54 M&L Preparation Old steel surfaces of any description, over 10 cm in width or girth, applying two coats of synthetic enamel paint (ordinary tint)all as specified and directed by Engr-in-charge. 55 Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete 56 M&L for ATT Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron all as specified and directed by Engr-in-charge. 57 Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specified and as directed by Engr-in-charge. 58 M&L for Machine cut kota stone of size 550mmx550mm thick 16 to 20mmflooringand skirtingthick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete to achieve mirror finish laid over & including 20 mm thic screed bed in CM 1:6 complete all as specified and directed by Engineer in Charge. 59 S&F mild steel Gde Fe-410-W as in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces , cleats etc.all as specified and as directed by Engineer in Charge. 60 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 etc all as specified and as directed by Engineer in Charge. 61 M&L for providing and applying URP 301, a polymer based bonding and waterproofing agent, mixed with cement in specified ratio and applied in two coats over cleaned and pre-wetted concrete / masonry surfaces as per manufecturers specification, including surface preparation and curing. Make : Pidilite Dr Fixit/ Fosroc/ Sika and equivelent etc all as specified and as directed by Engineer in Charge. 62 S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified by Engr-in-charge. 63 Taking down chowkhats or frame (w/o taking off shutters) and removing from site n.exc 1.5sqm each complete all as specified and directed. 64 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads in wooden/steel window etc all as specified and as directed by Engineer in Charge. 65 S&F clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane includingand glazing with oil putty etc all as specified and as directed by Engineer in Charge. 66 Demolition of cement concrete (Reinforcment) of any description all as specified & directed. by Engineer in Charge. 67 M&L for RCC in 1:2:4 type B-1(using 20 mm graded stone agg) as in chajjas facia, shelves, lintel etc and similar work all as spd etc all as specified and as directed by Engineer in Charge. 68 M & L for hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15 cm thick watered and rammed to a true surface in broken boulder complete all as specified and as directed etc by Engineer in Charge.. 69 M&L for 100 mm thick cement concrete 1:2:4 type B-2 using (40mm graded stone aggregate ) as in sub base of floor path and hard standing complete all as specified and directed by Engineer in Charge. 70 Taking Down old unserviceable rolling Shutter/Steel Gate/side hung shutter of area n exc 25 Sqm each of any description and refixing after over hauling including, necessary welding of iron flats, replacement of bottom strips, replacement of springs, replacement of Gear, replacement of ball bearing, replacement of MS Sheet Hood, making good surfaces, applying two coat Synthetic enamel paint over a coat of primer and refixing with smooth functioning Complete all as specified and directed by Engr in Charge. 71 S & Fsteel rolling shutters/side hung shutter (thickness of laths in 1.25mm),without ball bearing,as specified including top cover,anchoring rod,hasps and staple and one shop coat of primer :erected in position as indicated complete but gear operated type with bevel gear box and cranck handle including taking down old rolling shutter and makeing good wall surfaces, smooth functioning etc Complete all as specified and directed by Engr in Charge 72 S&F safety lever locks mild steel with 4 lever for rolling shutters 73 S&F ball bearing for rolling shutters 74 Schedule-A (EM Work) 75 Supply & Fixing air termination copper rod 12mm dia, 300 mm long for lightingg conductor 76 M&Lfor testt point terminal block made ou of gun mettal or phophorous bronze of sizes 75 x 75x25mm drilled & screwed including 3 hole, 8mm dia 25mmlong hexagonal head with nut and washers complete as specifiedand directed 77 M&L for lightening conductor copper strip20 x 3.15 mm drawnin GI pipe or buriedin ground complete all as specified 78 Supply only GI pipe light grade of size 40mm bore for erection of lightening conductor complete as requiredand directed by Engineer-in-Charge 79 M&L for provn of copper earthingg complette with MS copper earth plate electrode 600 x 600 x 6mm thickburieddirectly in ground (earth pit not less than 4.25 M deep below normal GL) with top edge of the plate not less than 3.5M below normal GL, conected to copper earth strip 20 x 3mm upto 7.5 mt withprotection pipe bymeans of bolts, nuts, check nuts & washers of GI or steelinclexcavaion, PCC ()1:3:6) typeC-1 chamber withRCC cover (1:2:4) type B0, 40mm thick reinforcedwith with 6 mm dia bar, 3 Nos both way, 40mm dia light grade GI protection pipe, funnel with wire mesh, waering pipe of size 20mm dia med grade, lugs, main earthing lead upto 7.5 mtr incl charcoal dust, salt etc all as shown in electrical platte No 5 of SSR Pt_I 2009 specification. 80 M&L for copper for opper brazin with coppr strip/coppr rod as directed by Engr-in-Charge 81 S&Foircelin insulator 15 BMD size T type with nut bolts screws for fixing of copper/aluminium/GI strip on wall/PCC blocks all as specified and directed 82 Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed. 83 Taking down carefully by unscrewing from theboards/outlets boxes fittings and fixturessuch as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbedsurfaces 84 Taking down ofexisting old unserviceable submain wiringcomplete all as specified and as directed. 85 Taking down ofexisting old unserviceable MCB of any ratingcomplete all as specified and as directed. 86 Taking down ofexisting old unserviceable distribution boardof any type complete all as specified and as directed. 87 Taking down of LED T/L/Ceilling light/Round light/Bulkhed light of any type and capacity complete all as specified and as directed. 88 Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles , GI screws , rawl plugs with all fittings including tees , junction boxes & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed by Engineer -In-Charge.Note: Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate. 89 For one light point controlled by one single pole switch & socket. 90 For one fan/exhaust/wall mounted point controlled by one single pole switch. 91 For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm 92 For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size 93 For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size 94 Supply and Fixing of modular switches 1 way, 6 Amp 1 module complete all as specified & directed by Engineer - In-Charge. 95 Supply and Fixingmodular Socket, 6A - 2/3 pin combined 2 module, complete all as specified & directed by EIC. 96 Supply and Fixing of modular switches 1 way, 16 Amp 1 module complete all as specified & directed by Engineer - In-Charge. 97 Supply and Fixingmodular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified & directed by EIC. 98 S&FGI Modular gang sunk-in pressedterminal boxes of required size not less than 1.2 mm thick factory made for following module complete all specified and directed.Note: Flushing of module box in wall with cement and repairing the wall as before is deemed to be included in quoted rate. 99 Metal flush box 3 module 100 Metal flush box8 module 101 S&F white cover plate with frame of following module complete all specified and directed. 102 white cover plate with frame 3 module 103 white cover plate with frame 8 module 104 Supply & Fixing of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed by Engineer - In-Charge. 105 Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 106 S&F submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 20mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 1.5 Sqmm single core HR Grade and one run of 1.5 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. 107 Ditto as above item but sub main wiring 2x2.5 sq. mm + 1x2.5 sq. mm earth wire. 108 Supply , Laying , testing and commissioning in replacement of XLPE insulated and PVC Sheathed , galvanized steel strip or wire armoured , heavy duty electric cable with multi stranded aluminium conductor, 1100 volts grade of size 16 sqmm 3 core complete all as specified & directed by Engineer - In - Charge. 109 M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :-Thickness of sand cushioning shall be measured after punning. 110 M&L for brick protection with sub class B Designation 75 old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed. 111 S&F in repair GI pipe light grade 50mm bore in trenches/wall/poles for protection of cable complete all as specified and as directed. 112 M&L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed. 113 S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed by Engineer -in -charge .Make : Make: Legrand /Siemens/Schneider. 114 Supply and fix in replacement of factory made epoxy polyster powder coated distribution board double doorSP&N 8 way 240V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate. Make: Legrand /Siemens/Schneider.
|