|
Tender For Provision Of Md Accommodation For 12 X Or At Rlt Viharunder Ge (N) Akhnoor; 2 Construction of block of OR Md accn including garages complete all as shown on drawings and as specified. 3 TotalAmount of Sch A Part - II (Internal Water Supply Work) 4 TotalAmount of Sch A Part - III (Internal Electric Supply Work) 5 TotalAmount of Sch A Part - IV (Plumbing Work) 6 TotalAmount of Sch A Part - V(Area Drainage Work) 7 TotalAmount of Sch A Part - VI (Sewage Disposal Work) 8 TotalAmount of Sch A Part -VII (Road, Path, Culver and Hard Standing Work) 9 TotalAmount of Sch A Part - VIII (External Water Supply Work) 10 TotalAmount of Sch A Part - IX (External Electric Supply Work) 11 TotalAmount of Sch A Part -X (Compound Wall , Fencing and Gate Work) 12 Sch A Part - XI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 13 Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly including taking down existing sub main wiring, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 14 Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes of suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour),single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-Note:- Allnecessary accessories such asmodular steelbox, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only. 15 One light/fan/bellpoint controlled by one switch 16 One socket outlet 05 Amps on the same board 17 One socket outlet 05 Amps on independent board 18 One light point controlled by two way switch 19 Point wiring complete with 2.5 sqmm PVC insulated, FRLSH, ISI marked, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20 mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; with modular metal flush box of suitable size as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 2.5 Sqmm PVC insulated multistranded FRLSH unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:-Note:- Allnecessary accessories such asmodular steelbox, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only. 20 LED Lamp retrofit type 12 watt, B22 base holder with polycarbonate body and heat sink type, complete all as specified and directed. 21 LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 V AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 22 LED inverter batten, 20W, length 110cm,with square profile and polycarbonate channel, lithium Ion battery with charging time 8 to 10 hours and backup time upto 4 hours, AC, 220V, 50HZ, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 23 LED lights fitting 20W, 220V,4 feet, general purpose surface and wall mounted LED batten with aluminium housing integrated electronic driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 24 Vertical TPN 06 way, 160A, IP 43 with MCCBincomer distribution board fitted with copper bus bar, neutral link, blanking plates, with suitable for incoming MCCB upto 160 Amp, 4 pole G frame, having isolated neutral bar, mechanical impact strength IK09, complete all as specified. 25 Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 15mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 26 LED security light fitting of capacity 25 Watt LED street light fitting in aluminium pressure die casting (PDC) housing, toughened glass cover including GI bracket of size 1.5m long, 40mm dia, GI pipe, made to shape fixed with clamps, nut bolts and all connected accessories, IP65 protection with suitable inbuilt surge protector and including cable connection from ceiling rose to light fitting complete all as specified and directed. 27 Lt switch gear control panel board 440 Volt, AC 3 phase, 4 wire for outdoor installation KIOSK TYPE with sloping canopy fabricated out of steel sections i.e; CRCA sheet 3.15mm thick, angle/channel and flat iron sections of suitable size with opening on front, door in two halves fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 65 standred with phosphatized powder coating painting externally and inernally to protect against corrosion. The panel shall be mounted on suitable size of channel section having ground clearance 60cms from grouting bolts, conforming to IEC 60439 complete duly incorporated and LT panel is mounted on MS angles legs of size (32x32x6)mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC (1:2:4) type B-1, (using 20mm graded crushed stone aggregate) including provision of opening for incoming/outgoing cables and having following accessories:- (Contd....this item in next page) 28 (i) Bus bar chamber with electrolytic grade aluminium strip with heat shrinkable sleeves with colour code supported on epoxy resinbased insulators 4 strip, of suitable length for current rating minimum 250 Amps.(ii) MCCB, 4 pole, 415V AC, current rating 100 Amps, breaking capacity 16 KA -01 No (Incoming)(iii) MCCB, 4 pole, 415V AC, current rating 63 Amps, breaking capacity 16 KA -03 No (Outgoing)(iv) Voltmeter digital type 0-500 V, 96mm square flush panel mounting -01No (on incoming supply)(v) Ammeter digital type 0-200 A, with CTs of suitale ratio, 96mm square, flush panel mounting - 01 No (on main load)(vi) Copper wiring complete all as directed by the Engr-in-Charge 29 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 30 Double walled corrugated (DWC HDPE) pipe of size 40mm/32mm including snap fit coupler conforming to IS 16205 for protection of under ground cable complete all as specified and directed. 31 Construction of brick masonry valve chamber of size 90cm x 90cm x 90cm (Internal dimension) with PCC 1:3:6 using 40mm graded crushed stone aggregate as in foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 using 20mm graded crushed stone aggregate as in coping, 50mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation, earth work in any type of soil, MS sheet cover 6mm thick fixed with angel iron frame 50x50x6mm with locking arrangement embedded in PCC and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed. 32 MCCB,4pole,415 volts,adjustablethermal & fixed magnetic setting type suitable for DB, 63 Ampswith breaking capacity 16KA, complete all as specified. 33 Deduction to be made from BOQfor Sch A Part -XII (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule.
|