Electrical works at FCI FSD Lunglei, Mizoram for the year 2025-26.SH: - Supply and Installation of LED Street Lights with Poles and Allied Electrical Works at FSD Lunglei, Mizoram under RO NEF.; 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C. 2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 3 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 4 Supplying and fixingfollowing size/modules, G.I box along with modular base & cover plate for modular switches in recess etc. as required 5 3 Module (100 mm X 75 mm) 6 6 Module (200 mm X 75 mm) 7 Supplying and fixing following modular switch/socket on the existingmodular plate & switch box including connections but excluding modular plate etc. as required. 8 5/6 A Switch 9 3 pin 5/6 A socket outlet 10 15/16 A Switch 11 6 pin 15/16 A Socket outlet 12 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB /Isolator) 13 8 way, SPN double door 14 Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 15 Single pole (10A) 16 Single Pole & neutral (32A) 17 Triple Pole and neutral (32A) 18 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. 19 Supplying of following size XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required. 20 4 x 16 Sq. mm 21 3 x 10 Sq. mm 22 3 x 6 Sq. mm 23 Supplying, Installation, Testing & Commissioning of LED surface mounted industrial Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 24 40 watt 25 Supply, installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with electroic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Ceiling Fan compliant to IS 374:2019 fan i/c external insulated copper conductor single core cable and earthing etc. as required. 26 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 27 Supplying, Installation, Testing & Commissioning of 40 Watt modern LED Post light fixture of yellow acrylic diffuser and powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66, IK-10, CRI >80, under voltage and over voltage protection, EMIEMC. As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 28 Supply of 5 Mtr. long Octagonal pole having bottom dia. 130 mm and top dia. 70 mm made out of 3 mm thick GI sheet having base plate of size 200 mm x 200 mm, 12 mm thick (along with foundation bolts) and 50 mm dia 80 mm long GI medium class curved (45 degree) pole bracket with suitable reducer above pole, connection window at a height of 0.80 Mtr. from the base plate with hinged cover locking arrangement, necessary dinbar, 1 No 6A SPMCB, 4 Way 15A connector complete as required. 29 Erection of Metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 30 Above 4.5 metre and upto 6.5 metre 31 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 32 mm dia 33 Providing, laying and fixing following dia G.I pipe (medium Class) in ground complete with G.I fittings including trenching (75 cm deep) and refilling etc as reqd. 34 50 mm dia nominal bore 35 Laying of one number PVC insulated and PVC shealthed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 36 upto 35 sq. mm 37 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. 38 Upto 35 sq. mm 39 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 40 upto 35 sq. mm (clamped with 1mm thick saddle) 41 Supplying and dawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required. 42 3 x 1.5 sq.mm 43 Supplying and fixing of 32 mm dia X 2.00 meters long G.I. pipe(medium class) bracket for mounting of fluorescent /HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamp with nuts, bolts and washer, paintaing the flat iron with primer and finish paint stc. as required. 44 P/F of cable termination of PVC box of size 20cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required. 45 Supplying, installation, Testing & Commissioning of Street light LED fixture with secondary optic and powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66, IK-10, CRI >80, under voltage and over voltage protection, EMIEMC. As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 46 72 watt 47 Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 48 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 49 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 50 Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as requuired. 51 4 x 16 Sq. mm (28 mm) 52 3 X 10 sq. mm (22 mm) 53 3 x 6 sq. mm (19 mm)
|