Tender for Supply And Delivery Of Various Typess Of Miscellaneous Supply And Repair Works At Urgent Basis As Required By Tic At Emrs, Mukutmonipur, Bankura-- 1 Repairing of all the high mast lights inside school campus. 2 Taking down and lifting up the solar high mast light by hydra for repairing 3 Replacement of rope inside the solar high mast pole 4 Alignment and balancing high mast pole and light holder ring 5 The outlet pipe for the smoke from the DG machine need to be extended. 6 DG smoke outlet pipe of sheet metal steel 10SWG 7 Joing the extended pipe with existing pipe by welding 8 Ms pipe for holding the extended smoke outlet 9 Bottom Support of Aquaguard water filter inside school building. 10 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, in ground flooras per relevant IS codes.; Pakur Variety [ for making RCC concrete slab of size = (1m X 1m X 0.2m) @ 2nos 11 Reinforcementfor reinforced concretework in all sorts of structuresincluding distribution bars,stirrups,bindersetcinitialstraighteningandremovaloflooserust(ifnecessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawingand direction. (a) For works in foundation and upto roof of ground floor/upto 4 m ;II. SHYAM/SRMB 12 Brick-on-edge floor or pavement with 1st class brick set close in cement mortar (1:6) and laid withcushionofsandbelow(includingcostthereof)includingruledorflushpointingwith cement mortar (1:4) on top. 13 With 1:6 cement mortar(b) 20 mm. thick plaster 14 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 15 One freezer. (Blue Star, 310 ltr double door) for Boys' Hostel. 16 Supply and delivery & Installation of of 310 liter Double door frezzer. ( Blue Star) 17 Aluinium works (Doors & Windows) 18 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732- 1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white, (A) In 10-12 Micron thickness Annodizing film I) Natural white, d) Shutter for all track sliding window 19 i) Bottom & Top member. 20 ii) Style side member. 21 iii) Interlock member. 22 Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. b) 'U' shaped EPDM gasket for frames 23 Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as perarchitecturaldrawingsanddirectionofEngineer-in-charge.10-12Micronthickness Annodizing film. Natural white. a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel with in 0.90 sqm (unit wt of Top, bottom & sidemember@1.366kg/m;intermediatemember@1.443kg/m;glazingclip:0.167kg/m respectively) [Note : for estimate purpose construction wing may consider weight of Al-Sections for Partition wall @ 5.7 Kg per Sq.M] 24 for fixed partitions at staff quarter [(3.1M. X 1.85M)= 5.74 Sq.M. @5.7KG/Sq.M.= 32.72 Kg. ] 25 School Building [(3 MX 2.1M)= 6.3 SqM. @5.7kg/Sq.M.= 35.91Kg.] 26 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steelscrews forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour,scaffoldingandallotherincidentalchargescompleteinallrespectasper specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) 27 at Staff quarter [(3.1M X 1.85M)= 5.74 Sq.M.] 28 School Building [(3 MX 2.1M)= 6.3 SqM.] 29 Supplying,fitting&fixingofpartlyglazedpartlypanelledorfullyglazedsingleleaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( toprail,bottomrail,lockrail,doorvertical),glazingclipmadeofAluminiumAlloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharg 3 nos of Amuminium Doors at different places [(1.0M X 2.1M)= 2.1Sq.M. @9kg/SqM. = 18.9Kg] 30 Supplying,fitting&fixingof2-Track/3-TrackAluminiumslidingWindowofallAluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conformingto IS 1868-1983, fittedwith all other accessoriesviz.PVC roller,EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3- trackslidingwindowwithfixingofglass(excludingcostofglass)allcompleteasper architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film ,Natural white.[Note : for estimate purpose construction wing may consider weight of 2- track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M]for 5 nos of window at different places [ (1.2MX1.2M) =1.44Sq.M@ 5.5Kg/SqM.= 7.92Kg.] 31 Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge. for Structural Glazing/Curtain wall. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work 32 Godrej Hydraulic door closer fitted and fixed complete. Medium type 33 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (ii) 100 mm grip x 10 mm dia rod. 34 Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. ii) 100 mm. 35 Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. Forr wooden door fittings (a) 200mm long 36 Door stopper (Anodised aluminium) 37 Repair of sliding windows(4ft x 5ft -5 pcs & 3.5ft x 5ft-3pcs) of Boys Hostel 38 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II); (i) 6mm thick [P-249, It-24, A,i] [1.2m X1.35m ]@ 8 nos and [1mX1.4M] @3 nos 39 Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge. for Structural Glazing/Curtain wall. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work 40 Shelf made with Plywood (approx size : 6 x 4 x 1 ft.) 41 Smart Board UPS Legend 1000 (Type: Line-interactive, Output Power Wattage: 600 W, Input Voltage: 140 V|Output Voltage: 230 V, Input Frequency: 50 Hz ± 10%|Output Frequency: 50 Hz ± 1 Hz, W x H x D: 13 cm x 18.3 cm x 31.5 cm)
|