Tender For Renovation Of Administrative Section At Icar-Ciwa, Bhubaneswar; 1 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 3 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge 4 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.,In cementmortar 5 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 6 20 mm cement plaster of mix :(1 cement: 4 coarse sand) 7 Laying of vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.,Size of Tile 600x600 mm 8 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.,With cement mortar 1:4 (1 cement : 4 fine sand) 9 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:, Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) 10 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 11 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 12 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :,For fixed portion,Powder coated aluminium (minimum thickness of powder coating 50 micron) 13 Providing and fixing aluminium work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately),Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side 14 Providing and fixing 19 mm thick solid ply (century/ Green ply /Austin) with both sides laminatedby sunmica of matching colour 1 mm thick for partition of aluminium framed work with all accessories, locking arrangement, hinges, bolt etc. 15 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). 16 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60 mm long and stainless steel expandable dash stener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer in-charge. 17 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately),Flat surfaces 18 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. 19 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 20 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood 21 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) Second class teak wood,30 mm thick shutters 22 Providing and fixing roller blind of 1mm thick with all necessary fittings and accessories 23 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 24 Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform (item code: 5.9.3) 25 Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers 26 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 27 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimumwall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mmfor Series R3 and R4 profiles conforming to EN: 12608 in any shape,colour and design duly reinforced with galvanized mild steel sectionmade of required shape & size as per CPWD Specification, uPVCextruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frameto finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements andconforming to IS: 3548 & IS: 16231 shall be paid separatelyThree track three panels sliding window with two glazed& one wire mesh panels with Aluminium channel for rollertrack, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screensash (30 mm & above) x (55 mm & above)with zinc alloy (zamak) powder coated handleon every glazed panel along with multi-pointlocking system. (Height upto 1.8m). 28 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 29 Supplying and fixing of following ways 8way(4+24) surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 30 Supplying and fixing following way6way(4+18), horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator(AC DB) 31 Supplying and fixing following way(12way), single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(UPS DB 32 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (4 X 10 sq. mm + 2 X 6 sq. mm earth wire) of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 33 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (2 X 6 sq. mm + 1 X 6 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(UPS line) 34 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(inverter line) 35 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. with dismantling of existing onewith white washing as required. 36 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(inverter line) 37 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 38 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(UPS) 39 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(power line) 40 supplying and fixing of Suitable sizePVC board with modular cover plate with 3nos. 5A,modular Switch and 3nos. 5A modularSocket as per requirement of the Institute. 41 supplying and fixing of Suitable sizePVC board with modular cover plate with 1nos. 15A,modular Switch and 1nos. 15A modularSocket as per requirement of the Institute. 42 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 1 no. 5 pin 15/16 A modular socket outlet and 1 no.25A modular AC starter, connections etc. as required. 43 Supplying and fixing of fan regulator as required. 44 Supplying and fixing of 5A modular socket and 5A switch as required. 45 Supplying and fixing of 100A MCCB (4 pole)as required. 46 Supplying and fixing of 63A MCB (4 pole)as required. 47 Supplying and fixing of32A DP MCB as required. 48 Supplying and fixing of32A SP MCB as required. 49 Supplying and fixing of20A SP MCB as required. 50 Supplying and fixing of10 A SP MCB as required. 51 Supplying and fixing of2ft.x 2ft. 40W LED ceiling light with dismantlingas per requirement of the Institute. 52 Supplying and fixing of 22W LED ceiling surface light with dismantlingas per requirement of the Institute. 53 Supplying and fixing of 400mmx 50mm DLP,bendas per requirement of the Institute. 54 Supplying and fixing of 26W BLDC fanas per requirement of the Institute with dismantling of existing fan.
|