Work Of Erection Of Structures, Equipments, Earthing, Control Wiring, Yard Lighting, Control-Room & Electrification Etc. For 2X15mva, 66/11Kv Dholera Airport Sub-Station.-1 Erection of equipment of any type/ Make with required all spares & accessories as per supplier's manual and FQP including indivisual & Interpole wiring of for all mentioned voltage class switch yard (as per respective technical specifications & relavant special conditions) suitable for all types of bus Configurations. Scope includes the dragging/loading/unloading of same from site store to erection site. (c)Erection of breakers-66/22 KV (without crane) 2 Erection of CT/PT/CVT (All type/make) on its erected structure including complete dragging/loading/unloading of same with crane only from site store to erection site and fixing of required clamps, connectors as per instruction of Engineer in-charge. (d) 66KV CT/PT/CVT (without crane). 3 Erection of Surge Arrester (All type/make) on its erected structure including complete dragging/loading/undoading of the same from site store to erection site and fixing of required clamps, connectors, corona rings, surge counter and other accessories etc. as per instruction of Engineer in-charge. (d) 66KV 4 Erection of centre breaker/Double break isolator (All make) with earth blade(without crane) on its erected structure consisting of 3 base channel with porcelain/solid core insulator including interconnector piping with operating mechanism and accessories with final adjustment for simulators operating & closing. The rates are inclusive of dragging/loading/unloading of the same from site store to erection site as per instructions of Engineer in-charge. (a) 66KV5 -DO- as above but without earth blade complete. (b) 66KV 6 Erection of polycone/Solidcore/Bus Post insualtor on its erected structure complete.fixing of accessories and shifting of same includong loading / Unloading from its site store to erection site. (d) 66KV 7 Laying of any size of 11/22KV XLPE cable including excavation of trench 300mm wide & 600mm deep including laying and filling up sand of 100mm layer from bottom & bricks on three side of cable & refilling the trench with murram/soil & ramming etc. Required bricks, sand, power cable maker/C.I/G.I plate etc. will have to be supplied by the contractor. Rates are inclusive of shifting of cable drum to the site from S/S site store. Drum should be handled only by jacking to avoid damage to cables. 8 (b) Laying of any size of 11/22KV XLPE cable in readymade cable trench or in open space. Rates are inclusive of shifting of cable drum to the site from S/S site store. Drum should be handled only by jacking to avoid damage to cables. 9 Erection of S/s & Equipment structure including punching of nut-bolts. Rates are inclusive of shifting of same upto erection site from its S/S store. (a) 66KV 10 Erection of 66/22-11KV Class Power Transformer with complete mounting of all the accessories i.e. busings, radiators, conservator tank etc. including laying of cable between all accessories mounted on the transformer / marshalling KIOSK filling and filtration of oil with filter machine as per direction of Engineer in Charge. manufacturer Engineer or as per instruction manual. Required filter machine, Hydralic jack, Vaccum Pump etc. for erection & oil filtration will be provided contractor. (iii) 15 MVA 12 Stringing of quardruple 'MOOSE' Bus complete in all respect with fixing of all fittings, insulators sag compensation spring and all accessories as per the instruction of Engineer in-charge.(c) - DO - but for Single 'MOOSE' /Zebra. 13 Preparing and fixing of required length of jumpers in the switchyard on respective Bus & equipments, tensioning & dressing of jumpers complete as per instruction of Engineer in-charge. (c) Single MOOSE / ZEBRA / PANTHER 14 Installation of earthing strips / MS round bar in any kind of soil except Rocky(HR/SR) Soil as per earthing philosophy of GETCO Earthing Grid: 1) Including digging of 600mm depth and 450mm wide trench. 2) Cutting, bending, laying and fixing of Earthing grid conductor. 3) 75x10mm / 50x6mm GI strips: Fixing of two bolt at each straight joints and lap welding, removing oxide films formed during welding, applying two coats of red oxide and black powder after welding and applying zinc rich paint on welded joints. 4) 25/32/36/40MM dia MS Rod: Lap welding at each straight & cross joints, removing oxide films formed during welding, applying two coats of red oxide and black powder after welding and applying zinc rich paint on welded joints. 5) Including supply of red oxide paint, black powder, HDGI Nuts & bolts as per specification. 6) Back filling of the trench with yellow/ Normal soil. Structure & Equipment earthing: 1) Including digging of 600mm depth and 450mm wide trench. 2) Cutting, bending as per required shape, laying and fixing of risers from Grid to structures and Equipments. 3) Lap welding, removing oxide films formed during welding, applying two coats of red oxide and black powder after welding and applying zinc rich paint on welded joints including supply of HDGI Nuts & bolts for all connections including suporting to structures etc as per specification. 4) Back filling of the trench with yellow/ Normal soil. b) 50 x 6 mm GI strip / MS round bay up to and including 25mm Providing Bore type earthing with drilling of minimum 200mm dia bore upto following mentioned depth in Rocky (HR/SR) Soil as per earthing philosophy of GETCO. 1) Work includes inserting 20/25mm dia MS Rod (for 66kV S/S) / 40 mm dia MS Rod (for EHV S/S) in bore depth and to be connected to the earthing grid at junction point by proper welding at both end. 2) This includes cutting, fabrication & welding of flat. 3) Refilling and compression of surrounding areas with Normal/yellow soil, ground enhancement material etc. wherever applicable as per approved Soil strata and earthing design calculation. 4) Required G.I. Earthing strip/ MS rods will be supplied by GETCO Free of Cost. 5) Earthing material like Normal/yellow soil, ground enhancement material (0.5CMT/Meter depth), water, etc. shall be supplied by contractor. (f) 3 Mtr Depth (a) Supply,Installation,Testing and commissioning of maintenance free treated earth electrodes suitable for NORMAL SOIL as per drawing No. GETCO/E/STD/P-021 (1 OF 2) R3 dated 29- 05-2020 and technical specifications GETCO/E/TS-Maintenance free earth pits/R1 dated 04-06-15 for 66/11 kV substations with ground enhancement material/ back fill / grounding compound as per IEEE 80-2000 Clause 14.5 (d) and as per part-7 of IEC-62561 Using Copper bonded earth electrode (with 250 micron copper coating) having 24 mm dia (min) and 3000 mm length which shall be capable of handling STC of 25 KA-1 sec. Work also includes Providing BB masonary inspection chamber(manhole) incl. light type CI cover.17 Fabrication for erection of any Equipment/Structure/panel or anywhere in s/s & F.B. at other endas per Inst. Of E.I.C. L.S. (Max.) 18 Erection of support structure for 11kV Power cable termination at 11kV bushing for 10/15/20MVA power transformer as per Drawing No.:- GETCO/E/06SSTD/ 11kV STR-A2-02. 1) Material for supporting structure will be supplied free of cost by GETCO. 2) Necessary wooden clamps with required nut-bolt-washers & HDPE rubber piece for packing etc. as per drawing shall be supplied by the contractor. 3) Job also includes minor fabrication if required as per instruction of EIC. No 19 Erection of support structure for station transformer as per GETCO Drawing No.:- GETCO/E/06S-STD/11kV STR A3-03. 1) Necessary wooden clamps with required nut-bolt-washers & HDPE rubber piece for packing etc as per drawing shall be supplied by the contractor. 2) Job also include erection of required 11kV LA, D.O. Fuse and any miNo.r fabrication if required as per instruction of EIC. 3) Material for supporting structures, DO Fuse and 11kV LA will be supplied by GETCO Free of Cost. No 20 Providing & fixing Set of following Items on erected 11kV support structure system for power cable of 66/11kV Transformer as per GETCO drawing No..GETCO/E/06S-STD/SPL-028A, R3, DT-26.10.2016 and instruction of EIC. 1) Allu. alloy bus bar of size 120X20X2000 mm with heat shrinkable anti tracking tubing : 03 Nos. 2) 11kV SRI of PCD 127 mm - 12 No. 4) Copper laminated fusion welded flexible jumper of size 75 X 10 X 600 mm having 2000 Amp capacity : 03 No. (4) Bi Metalic Plate (Al/Cu): 03 No. (5)11kV Heat Shrinkable anti tracking Sleeve on Al Bus bar of all three Phase: 06 mtrs (6) Including required GI/SS nut-bolt and washer of good Quality for fitting support structure. (7) All live parts shall be coverd with heat shrinkable MV insulated tape/ sleeve. Set Erection of 11kV D.P. Structure as per GETCO Drawing No.: GETCO/E/06SSTD/ 11 kV STR- A1-01. (for outgoing feeder) 1) Job includes erection of 11kV A/B Switches, 11kV PI, jumpering between 11kV cable to 11kV bus, etc. on erected structure. 2) Material for DP structure, AB switches, PI and conductor for jumpers will be supplied free of cost by GETCO. 3) Necessary wooden clamps with required nut-bolt-washers & HDPE rubber piece for packing etc. to hold 11kV power cable as per drawing shall be supplied by the contractor. 4) Job also includes miNo.r fabrication if rquired as per instruction of EIC. Erection of 11kV D.P. Structure as per GETCO Drawing No.: GETCO/E/06SSTD/ 11 kV STR- A4-04. (for cross boundary protection) 1) Job includes erection of 11kV A/B Switches, 11kV LA, jumpering between 11kV cable to 11kV bus, etc. on erected structure. 2) Material for DP structure, AB switches, PI and conductor for jumpers will be supplied free of cost by GETCO. 3) Necessary wooden clamps with required nut-bolt-washers & HDPE rubber piece for packing etc. to hold 11kV power cable as per drawing shall be supplied by the contractor. 4) Job also includes miNo.r fabrication if rquired as per instruction of EIC. Stringing of Single ACSR Dog bus between 11kV D.P. Structure (A1) to cross boundry structure (A4) in all respect.1) Job includes fixing of all fittings and accessories on erected DP structures.2) Single tension hardware suitable for ACSR Dog Cond.- 6 set shall be supplied by the contractor. 3) Necessary ACSR DOG conductor, 11kV Insulators will be supplied by GETCO free of cost. Providing of M15 Grade Concrete for various equipment structure, Guy, 11kv DP, M.K. Box, Neutral channels, cable support channel, grouting of Pole/ Flood light structure with cement, sand & metal in proportion of 1:2:4 respectively. The rates are inclusive of supply of sand, metal, water & cement ,Muffing and with smooth cement mortar (1:6) finish. Loading, Transporting & Unloading of all Materials for 66KV Substation like Structure, indoor & out door Equipments, DP Structure,earthing materials etc.for sub station & opposite end feader bay from Store to 66KV S/S Site. Supply & laying of 1 CoreX25mm2, armroured Copper Cable, multi-strand flexible of approved make ISI marked in ready made trench or PVC pipe from Battery Charger to Battery Set including termination at both side as per inst. of EIC. Providing and fixing of various type of sign Board, sticker, Big Sign Board, earthing pit board, earthing pit Board & Single line diagram etc as per instruction of IEC. Sticker of red, white, black Letters are to be utilised for various sign board. Earthing Pit Board Size:- 6" x 6" -30 Nos. Safety Slogan Board, Hard Sheet board size 2' x 2'and 4mm thick (Gujarati Language) with red and Yellow colour.-02 Nos. Safety Slogan Board, Hard Sheet board size 3' x 2'and 4mm thick (Gujarati Language)- 3 Nos. Single line diagram size 5' x 3' Digital with Alluminium frame with fitting and as per approved diagram given by IEC.-01 No. Big sign board size 5' x 4' and 2mm thickness indicating sub station name digital with S.S. rod with hole & as per approved symbol with fitting charge.- 01 No. Switch yard sign Board 12" X 6" with 2 mm Thickness black & white Gujarati language.- 25 Nos. Safety Slogen Board size 2" x 6" in side control room.-05 Nos. Various type of control room equipment sticker size-24 cms x 5cms.--18 Nos. Safety picture board size :- 3' x 3' (Laminated for O/D use)-03 Nos. Name plate board of transformer size :- 2' x 1'- 04 Nos. Cable marker size:- 6" x 6", Radium, fixed on 750mm long M.S.Rod for fixing arrengement.- 30 Nos. P&F Radium sticker for outdoor and lndoor Equipment identification like LA, isolator, Circuit Breaker, Transformer, CT, PT, MK BOX, C&R Panels 11KV Panel board etc, Providing and Fixing of fire stand made from 75mm dia Gl pipe A class ISI mark heavy duty having 5ft width and 4ft height as per inst of Engr. In charge 1) Work includes cutting, drilling, welding of pipe as required. Fabrication and supply of 16mm dia meter hook size required for hanging the buckets. 2) 4 Nos.of fire buckets are to be provided by the contractor. 3) Fire stand should grouted with excavation of pit size 300mm x 300mm- 2 Nos. of 600mm depth with 1:3:6 mix muffing 300mm in height including leveling of stand. 4) The fire stand is to be painted with post box red colour of approval quality as per instruction of EIC. 5) All required approved material including cement, sand, metal etc are to be provided by contractor. Labour charge for fixing of 11KV XLPE Indoor/Outdoor cable kit of any make for size 95 to 300mm2. Cable kit provided by GETCO. Providing & Fixing of RAYCEM/MSEAL/CABSEAL or equivalent GETCO approved make heat shrinkable type 11kV XLPE Indoor/Outdoor cable Termination kit suitable for 11kV, 3C x 95 sqmm to 300 sq.mm XLPE power cable. Providing & Fixing of Aquaguard Total Reviva Water R.O. Plant including Commissioning & Testing and also with required peripherals for installation of plant as per site condition 1) Dimension: 320 X 275 X 410 mm 2) Weight : 8 KG 3) Water flow : 8 to 12 LPH 4) Input power : 230V AC 5) RO membrence : TFC spiral You have to provide guarantee for the 12 month from the installation. Providing and fixing of ISI mark Rubber Matting sheet Suitable for 11kV Class As per following specification. Reference IS:15652-2006 with latest amendment. Suitable for Voltage Class :B Max Use Voltage : 11kV AC proof voltage : 22kV Dielectric strength : 45kV Leakage current : < 10 micro ampere Colur RED/BLUE Make : Vardhman or equivelent ( Rubberhouse India) Width :1mtr. Thickness :2.5 mm. Surface :Chequred on one side and other side plain. NOTE: Contractor has to supply Rubber Matting sheet as per IS:15652-2006 with latest amendment specification and shall submit test certificate for routine test as per relevant IS Providing & fixing of reputed make ISI mark Fire Extingusher.with latest ammendment Dry chemical powder 9 kg Capacity. Note: Contractor shall submit Test certificate for routine test as per relevant IS. a) Chemical powder 9 kg b) CO2 type - 6.5Kg c) CO2 type - 22.5Kg d) Mechanical foam type - 50Ltr Providing & fixing of all weather proof, cold rolled sheet steel AC Panel - 2 for Yard-Light AC supply having (1) 63A 4P MCB : 01 No. (2) MCX-12A contactor : 01 No. (3) Digital Timer : 01 No. (4) 20A TPN MCB : 06 Nos (5) Indication lamp " 03 Nos (6) Push Butten : 02 Nos (7) Terminal Connector as per site requierment and other detail as per drawing enclosed including grouting & Necessary fabrication of GI Angle or fixing on GI Structure, including earthing with main grid as per instruction of EIC. Providing & fixing of all weather proof, cold rolled steel sheet floor mounted fixed type single door grey color Main AC Dist box having size 900x600x250 mm with door closing arrangement and necessary rubber gasket.Contractor has to supply following materials with box along with necessary mounting and wiring.(1) L&T/Anchor/Havells Make 100A,4P MCCB - 1 No.(2) L&T/Anchor/Havells Make 63A,4P MCB - 2 Nos.(3) 100 A Copper Bus-Bar Link - length 6 inch size & 25 x 3 MM - 4 Nos.(4) Tinned Earth Bus 25 x 3 MM Length - 32 Inch - 1No.(5) 25 & 16 sqmm Cu. flexible cable - 4 & 8 Meter respectively.(6) Required Nos. of Cu. Lugs , etc. as per instruction of EIC. Supplying & laying of following size Control/L.T power cable in readymade cable trench or by excavating in any type of soil cable trench size 1 ft. wide 2.5 ft. depth and refilling the same as per the direction of EIC. Item Includes the cable laying upto termination box with clamps & proper clamping of cable on gantries by GI pipe & glands as per direction. Item includes providing & supply of bircks, sand as per requirement. The L.T power cable to be provided by contractor as under :As per ISI 1554 (Part-I). 3.5 Core x 50 mm2 Alluminium cable - Armoured, from distribution X'mer to LT panel board (LTPB) - both 2 runs. Supplying & laying of following size Control/L.T power cable of FINOLEX or equivalent ISI make in readymade cable trench or by excavating in any type of soil cable trench size 300mm wide and 600mm depth and refilling the same as per the direction of EIC. Item Includes the cable laying up to termination box with clamps & proper clamping of cable on gantries by GI pipe & glands as per direction. Item includes providing & fixing of bricks, sand as per requirement to protect cables . The L.T power cable to be provided by contractor as under :As per ISI 1554 (Part-I). 4 Core x 25 mm2 Aluminum cable - read and clearly understood all the above terms & conditions and accept here with Bidder Armored, from LT panel board (LTPB) to Yard Light AC MK (AC Panel-2), AC Panel- 1 in C.R and Yard AC Box - - do - - 4C x 4mm2 Copper cable - Armoured, from yard-light AC MK (AC panel-2) to all yard-light fixture junction boxes on LM & street light light pole & Station transformer to Colony & LT panel to watchman cabin. Note: Cable Laying work either in ready made cable Trench or by excavating in any type of soil if required.(Only laying Cable will be supplied by GETCO) - - do - - 4C x 2.5mm2 Copper cable - Armoured, from yard-light AC panel-2 to all junction boxes on post top lantern Note :- Cable Laying work either in ready made cable trench or by excvating in any type of soil if required.(Only laying. Cable will be supplied by GETCO) Providing & fixing of 'B' class ISI marked GI. Pipe of 32/40mm dia for cable looping & road crossing with necessary elbow/band for each pole & J.Box for yard lighting & for control-room flood lights wiring work with fixing on wall with shadles if required as per inst. Of EIC. Providing & erection of 7.0 Mtr. long swaged type welded GI tubular street light pole on the foundation in any type of soil as per inst. of E.I.C. confirming to relevent IS and as per atached Drawing No. GETCO/E/STD/LTG.POLE -R2, DT-24-12- 2019 Providing & erection of 4.5 Mtr. long swaged type welded GI tubular post top lantern pole on the foundation in any type of soil as per inst. of E.I.C. confirming to relevent IS and as per atached Drawing No. GETCO/E/STD/LTG.POLE -R2, DT-24-12- 2019 Supply and fixing of Pole/Wall/Structure mounted FRP junction box standard make of required size with clamp, providing 1 SPN MCB G class of 16 A having short ckt breaking capacity of 10KA peak of standard ISI make like L&T/ANCHOR/MDS /HAVELLS & 2 Nos. of stud type connector of standard make like Connectwell. The cable glands & lugs are also included for clearly understood all the above terms & conditions and accept here with Bidder both incoming & out going cablesAmp. of standard make like MDS/HAVELLS & 2 Nos. of stud type connector of standard make like Connectwell. The cable glaneds & lugs are also included for both incoming & out going cables. Earthing to tubular pole/luminaries by coil type earthing at 10 SWG, GI wire in earth pit of 1.5 mtr. Depth in any type of solil by using salt/ coke (charcole) 16 kgs each & remaining filling with BC soil & clamping the earth wire with pole & Junction box. Providing and fixing of Single Piece Cast Alluminium with full frame with Acrylic Cover integrated luminaries Energy Efficient flood light luminaries on swaged pole / GI structure by providing required fabrications, of Philips/CGL/Bajaj/GE/Osram make, suitable for 1 x 250 Watt HPSVT with allied accessories such as Capacitor igniter, ballast, control gear box etc, 4 core 2.5 sq mm double insulated flexible stranded wire should be used from control gear titting to junction box. Providing & Fixing of 50W LED Lighting Fixture (CGL Cat No. LCTLR-50-FO-CDL 50W or equivalent under Cat-II or above as per R&B SOR), 4-core 2.5mm2 double insulated flexible strended wire should be used from control gear fittings to approved SMC type junction box as per inst. of EIC. Providing & Fixing of LED Street Light Fixtures (IX120W) (CGI- Cat No. LST0120/CDL 120W or equivalent under catIl or above as per R&B SOR ), 4-core 2.5mm2 double insulated flexible strended wire should be used from control gear fitting to approved SMC type junction box as per inst. of EIC Providing & fixing of 1x40W LED Post Top Lantern fixtures (CGI- cat No. LPTO- 40/CDL 40W or equivalent under cat-Il or above as per R&B SOR) complete fitting in all respect and 4 core x 2.5 mm2 double PVC flexible copper cable from control gear fitting to SMC junction box as per instruction of EIC. (4 no are to be provided on Main gate 3 No are to be provided on 5 Mtr Tubular pole) Providing and fixing of DBS as AC Panel 1 for CR of ISI marked Powder coated Pearl DBS of ivory color , wall mounting, Double door Distribution board of L&T, Heggar or higher make fitted with 63Amp Phase Bus bar, Earth / Neutral Bars and inter connecting wires with removable bottom gland plates for all power cable entry from bottom with DIN Channel ,incoming contact and INO - 63Amp TPN MCB 'C' Series 06 Nos -20 A SP MCB 'C' series and 13 NO -10 SP MCB C series All MCBs are L & T , Anchor or Higher make only.Complete in all respect and per instruction of EIC. Supplying & Laying Sub-main lines of 3X2.5 mm2 ( two for P & N and one for Earthing) copper PVC insulated wier of ISI brand in suitable standard make steel conduit pipe having minimum 1.5 mm thickness of approved brand with ISI brand with clmpes with it's associated accessories for various circuits amanating from AC panel 1.as per ins.E.I.C Point wiring for control room tube lights, fans, exhaust fans, fancy lights, water tight bulk head lights with PVC insulated 660 V grade standard copper wire in ISI make Gl conduct pipe 20 mm dia and 1.6 mm wall thickness size fitted with saddles on the wall/ceiling. Size of wire shall be with 3C x 1.5 sq.mm PVC insulated copper wire for phase and neutral and earth wire [ Green] and 5 Amp Anchor/Roma or any equivalent switch as per specification with 16 guage M.S. box. The box shall be covered with 3 mm thick decorative mat finish hylum sheet. The work is all inclusive of supply and fixing required materials as afore said [ like M.S. conduit pipe , saddles , switches , M.S. box , ceiling Rose , flexible copper wire etc] to complete point wiring with each fixture to be earthed by SWG-12 stranded copper conductor having green colour as per direction and instructions of E.I.C. Providing, fixing & termination for Emergency D.C. supply arrangment. This job includs supply & laying of 2C x 2.5 mm2 Copper arrmoured cable from battery charger to SBDC, fixing & providing SBDC & complete wiring with supply of wire & D.C. lamp (110V D.C., 100 watt-4 Nos.) in standard steel conduit pipe as per inst. of E.I.C. Providing and Fixing points wiring in Gl. Conduct pipe size 20 mm dia and 1.6 mm wall thickness with single PVC insulated 2.5 Sqmm. copper wire of ISI standard good quality using 1.5mm thick suitable size ISI mark ( 2+3 pin in socket ) Anchor brand 15 Amp. 250 Volt plug socket as separate plug point with shock proof accessories incl. indication lamp erected on separate decorative mat finish hylum sheet board on wall with providing adequate green earthing wire as per specification and instruction of Engineer In charge. ---- Do ---- as above but with single PVC insulated 3Cx1.5 sq. mm.copper wire of ISI mark plug socket for 5A domestic use separate plug points per direction and instruction of E.I.C. ---- Do ---- as above but looped on same board i.e. no separate board, plug socket for 5A domestic use as per direction and instruction of E.I.C. Providing and Fixing of Ceiling Fan of 1400 mm sweep Bajaj/Crompton / Orient/ usha / Cinni make (ISI approved) flexible wiring by using twin core double PVC 48/0.2 mm copper flexible cord of suitable & approved make and size from ceiling rose upto fan terminal & supply and fixing of energy saver regulators , extra GI pipe of required size and length for lowering of fan if required as per instruction of EIC. Providing and fixing of 41.5W LED Lighting Fixture (CGL Cat No. LPFC-36- CDL 41.5W or equivalent under Cat-II or above as per R&B SOR) as per instruction of EIC. Providing and fixing of 40W (1X4) LED Lighting fixtures as per drawing (in office area & Porch Area) (CGL Cat No. LCTLSN- 40-CDL (1X4) 40W or equivalent under Cat- II or above as per R&B SOR) as per instruction of EIC. Providing & fixing of 30W LED Street Light Bulkhead (CGL Cat No. LSTO-30- CDL 30W or equivalent under Cat-II or above as per R&B SOR) on out side C/R building and inside cable trench in C/R including wiring from ceiling rose to fixture with suitable size of PVC insulated ISI marked copper wire only as per Instruction of EIC. Providing and fixing of heavy duty exhaust fan in battery room size 18" of Make GEC/KHAITAN/ CROMPTON/ BAJAJ incl. M.S. louver shutter of Fan & necessary wall finishing works and applying bird proof net on outside wall with required arrangement for rain water sealing and necessary conection from ceiling rose as per Direction and instruction of EIC. Providing & Fixing of Electric bell with bell switch near officer's table. All materials must be ISI mark and approved by EIC. Providing and fixing of 18W LED Lighting Fixture (CGL Cat No.. LCTL-18-CDL 18W or equivalent under Cat-II or above as per R&B SOR) as per instruction of EIC Providing & fixing of Wall Mounted Fan Crompton / Orient/ PSPO / Usha / Cinni must be ISI approved). including wiring from ceiling rose to Fan terminals of by using twin core flexible PVC to PVC 48 / 0.2 mm copper cord of suitable & approved size & fixing of Fan regulator. Providing and laying of 2 core, 2.5 sq. mm PVC armoured copper cable of standard ISI make , inside hume pipe / cable trench / in ground, from control room / transformer distribution board to junction box of quarter & main switch of watchman cabin. During laying of cable in the ground, excavation of 300mm width and 450mm depth in any soil with murrum refilling to be done. This includes supply of saddles on the wall as instructed and approved by E.I.C. Cutting, uprooting and removing of grass, shrubs, bushes etc. from area as per priority given by E. I. C and also removing unwanted plants like Bordies, Ankdas, Nafatias, etc. to be excavated uproots. Also includes disposing off of cut grass, shrubs and unwanted plants outside etc
|