Complete Cleaning Services For Window And Split Air Conditioning Equipment (Evaporator And Condenser). The Heat Exchanger (Coil), Axial Fan, Fairing, Drain Gutter And All Components Must Be Cleaned. It Is Necessary To Remove The Equipment From The Location Where It Is Installed. The Service Will Include All Necessary Inputs And Execution Of The Service And Subsequent Reinstallation Of The Equipment. For Equipment Up To 12,000 Btus., Drain Trough And All Components. It Is Necessary To Remove The Equipment From The Location Where It Is Installed. The Service Will Include All Necessary Inputs And Execution Of The Service And Subsequent Reinstallation Of The Equipment. For Equipment From 18,000 To 24,000 Btus., Drain Trough And All Components. It Is Necessary To Remove The Equipment From The Location Where It Is Installed. The Service Will Include All Necessary Inputs And Execution Of The Service And Subsequent Reinstallation Of The Equipment. For Equipment Above 30,000 Btus., Complete Installation Of Window And Split Air Conditioning Equipment. The Service Must Include Relocation Of The Device (Even To Another Address), If Necessary. For Equipment Up To 12,000 Btus, If Necessary. For 18,000 Btus Equipment, 12/08/2025 - 11:47:16, If Necessary. For 24,000 Btus Equipment, If Necessary. For Equipment Above 30,000 Btus, Complete Uninstallation Of Window And Split Air Conditioning Equipment. The Service Must Include Relocation Of The Device (Even To Another Address), If Necessary. For Equipment Up To 18,000 Btus, Service Provision - Labor Corrective Maintenance Of Air Conditioners - By Call. Observations: Includes Displacement And Initial Diagnosis., Refrigerant Gas For Air Conditioning - Kg, Capacitors In General. Capacitors 15Mf To 45Mf + Or - 5%, 450-Vac- Pin- 50/60Hz: Operating Class Class B (10000 H) Class C (3000 H); Safety Protection Class P2/P1; Voltage Range 200 ~ 500Vac; Capacitance Range 2 ~ 120Mf; Capacitance Tolerance ±5%; Dissipation Factor 20 × 10-4(100Hz, 20 & #8451;); Terminal Voltage Test For Onu Utt 2 Terminal For 2 Seconds; Terminal Voltage Test For Utc Case (2Un + 1000) Vac Or 2000Vac-50Hz For 60 Seconds; Insulation Resistance 3000 M.Mf(100Hz, 15 To 45 & #8451;, 1 Min). Mini Box Capacitors 1.5Mfd To 2Mfd + Or - 5% - 450V With Double Terminal. Capacitors 1.5Uf To 5Uf, Tolerance + Or - 5%, Voltage: 450Vac, 50/60Hz; Capacitance Tolerance ±5%; Dissipation Factor 20 × 10-4(100Hz, 20 & #8451;); Terminal Voltage Test For Onu Utt 2 Terminal For 2 Seconds; Terminal Voltage Test For Utc Case, Fan Motor 7,000 To 18,000Btus, Nominal Power: 30W To 45W - Operating Voltage: 208~ 220V - Mains Frequency: 60Hz - Operating Voltage: 0.35A To 0.4A, Rotation: 850 Rpm Anticlockwise, Protection Class: Ip65., Fan Motor 24,000 To 30,000Btus - Nominal Power:45W To 74W - Operating Voltage: 208~ 220V - Mains Frequency: 60Hz - Operating Voltage: 0.4A To 0.48A, Compressor Ae 240 Air Com. Up To 9000Btus Rotating Capacity: 5/8 A 1 Ph Lra22.0 -Voltage 208~220V - Frequency: 60Hz -Gas Type: R22 Suction Line Connection: 3/8¨ Discharge Line Connection: 1/4¨, Compressor Ae 240 Air Com. 12000 Btusrotating Capacity: 1 Ph Lra26.0 -Voltage 208~220V -Frequency: 60Hz -Gas Type: R22 Suction Line Connection: 1/2¨ Discharge Line Connection: 1/4¨, Ae 240 Air Compressor
|