Tender For Electrical & Allied Works For Sbi Chaman Vihar, Dehradun o. Wiring for light point/ fan point/ wall fan point/ exhaust fan/ light sockets etc. with 1.5 sq.mm. PVC insulated 1100 V Grade copper conductor (FRLS) wires & 1.5 sq.mm. copper earth wire in concealed/ surface using 16 SWG MS conduits, accessories such as bends, tees, saddles, draw boxes, mounting boxes, inner plates, cover plates, ceiling rose etc (whereever required) and chromium plates brass screws/ rowel plug etc. The circuit wiring starting from DB to point control box/ switch box using 2 X 2.5 sq.mm PVC insulated 1100 V grade multi- stranded copper conductor wire & 2.5 sq.mm. PVC insulated earth wire (color code to be used ). (Flexible conduit/ elbow not allowed). The conduit to be laid in ceiling with proper clamps/ wall/ floor and flling the chase with cement mortar and finishing the same in original form/ wooden partition/ above false ceiling with proper clamps etc. all complete. i) Each circuit shall have independent earth wire. ii) Each point shall be earthed. iii) Circuit wiring is to be included in point wiring rates. i Primary light points controlled by one 6 amp. Modular switch Nos. ii Secondary light points controlled by one 6 amp. Modular switch Nos. iii One call bell point with ceiling rose/ 6amp. 3 pin socket controlled by one 6 amp. Push Modular switch. With call bell Nos. iv One wall fan/ exhaust fan point controlled by one 6 amp. Modular switch. The switch should be at switchboard level Nos. v One 5 pin socket controlled by one 6 amp. Modular switch complete assembly includes plate box etc. Nos. vi Same as serial no 1 but using 2*2.5 + 1*2.5 Sqmm Copper Conductor FRLS wires from DB to first 6A, 5 Pin modular socket controlled by one 6A switch and looped to the nearest second point with same 2*2.5 + 1*2.5 Sqmm copper conductor wires FRLS insulated 1100V grade. Nos. b Nos. vii Same as serial no 1 but using 2*2.5 + 1*2.5 Sqmm Copper Conductor FRLS wires from DB to first 16 Amp MCB two Nos. for Glow sign Board. Nos. SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 2 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT a) Primary point 7.00 0.00 Secondary point 6.00 0.00 3(a) 4.00 0.00 2.00 0.00 2.00 0.00 4 COMPUTER POINTS a Primary 4.00 0.00 Secondary 8.00 0.00 Same as serial no.1, but wiring for 16 Amp, 6-pin sockets by using 2*4 sq.mm. PVC insulated 1100 V grade copper conductor wire with independent 1* 4.0 sq.mm earth wire from D.B. to first point 1st socket and 1 st to 2nd, socket with 2*2.5 sq.mm. and 1*2.5 earth wire including providing and fixing of 16 Amp, 6 –pin socket with 16 Amp. Switch. (Modular type switch/ socket/ plate etc. complete assembly). Nos. b) Nos. Same as serial no.1, but wiring for A/C socket by using 2*4 sq.mm. PVC insulated 1100 V grade copper conductor wire and earthing with 1*4.0 sq.mm. PVC insulated 1100 V grade copper conductor wire with modular type 2 Nos. AC box (tiny trip type) with socket complete in all respects controlled by 25/32 A SP MCB - one to be provided near indoor unit and second near DB. The point starts from DB to stabilizer to the point near the indoor unit including top. Nos. 3(b) Same as serial no.1, but wiring for A/C socket by using 2*4 sq.mm. PVC insulated 1100 V grade copper conductor wire and earthing with 1*4.0 sq.mm. PVC insulated 1100 V grade copper conductor wire of weather proof type 2 way SPN DB complete in all respects controlled by with 32 Amp (10 KA) MCB to be provided near outdoor unit. The point starts from DB to the point near the outdoor unit. Item to also include termination lid between MCB and outdoor unit. Nos. 3(c) Same as serial no.1, but wiring for A/C socket by using 4*6 sq.mm. PVC insulated 1100 V grade copper conductor wire and earthing with 1*6.0 sq.mm. PVC insulated 1100 V grade copper conductor wire and weather proof type 4 way SPN DB complete in all respects controlled by with 32 Amp TPN (10 KA) MCB to be provided near outdoor unit. The point starts from DB to the point near the outdoor unit (includes wires for terminal connection of outdoor unit from TPN) including wiring to the terminals of the outdoor unit from weather proof box. Item to also include termination lid between MCB and outdoor unit. Nos. Wiring with 2x2.5 sq.mm. + 1x2.5 sq.mm. PVC insulated 1100 V grade multi stranded copper conductor wires in 2 mm thick PVC conduit from UPS DB to computer point. Each point to have 3 nos. 6 amps. 5 pin modular type sockets, one 6 amps modular swtich with all accessories, inner/ outer plates, metal box etc. and to be fixed on wooden partitions/ by grouting on wall etc. as per requirement at site. The switch should be fixed above the top of counter with indicator and sockets under the counter. Nos. Nos. SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 3 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT Primary 2.00 0.00 Secondary 2.00 0.00 B. 1.0 TELEPHONE SYSTEM 1.1 6.00 0.00 1.2 a) 1.00 0.00 40.00 0.00 2 COMPUTER NETWORKING 2.1 14.00 0.00 2.2 1.00 0.00 2.3 1.00 0.00 2.4 9.00 0.00 2.5 Supplying and fixing Patch Cord-1 Meter- 14.00 0.00 b Wiring with 2x2.5 sq.mm + 1x2.5 sq.mm PVC insulated 1100 V grade multi stranded copper conductor wires in 2 mm thick PVC conduit from UPS DB to computer point. Each point to have 1 nos. 16 amps 5 pin modular type sockets, 1 No's 16 amps modular swtich with all accessories, inner/ outer plates, metal box etc and to be fixed on wooden partitions/ by grouting on wall etc as per requirement at site. The switch should be fixed above the top of counter and sockets under the counter. or as directed by the engineer incharge for the E- lobby, Fire, Token Vending. Nos. Nos. CONDUITING FOR TELEPHONE, COMPUTER & CONDUITING, WIRING FOR T.V. SYSTEM. Wiring for VOICE from Jack Panel in data rack to computer workstation with Cat-6 voice cable in PVC conduits of size 20/ 25 mm including providing ferrules at both ends and termination at both ends including providing & fixing frame for telephone socket with shutter, RJ 47 outlet, faceplate and mounting box complete of modular type. This work includes supply and laying of CAT-6 cable in PVC conduits throughout the lenght, from the I/O hub to the point. Nos. Supplying, laying, effecting terminations, testing and commissioning of 0.51 mm dia Cu. Conductor, twisted, colour coded with polythene capor barrier, telephone cables in the existing tray or in conduit including providing &fixing conduit pipe or cable tray as required from building tag block to the floor as required. Supplying & fixing 20 pair krone tag block with enclosure. Nos. b) P/L 20 Pair of PVC insulated PVC sheathed multi core jelly filled armored telephone. Mtrs. Wiring for computer networking from Jack Panel in data rack to computer workstation with Cat-6 computer cable in PVC conduits of size 20/ 25 mm including providing ferrules at both ends and termination at both ends including providing & fixing frame for Cat-6 with shutter, RJ 45 outlet, faceplate and mounting box complete of modular type, This work includes supply and laying of CAT-6 cable in PVC conduits throughout the lenght, from the I/O hub to the point. Nos. Supplying and fixing 9 U (Rack with glass door, opening in the front power panel 1 (horizontal), cable manager 1 lock & key). Nos. Supply, Installation, Testing & Commissioning of 24 port Jack Panel. Nos. Supplying and fixing Patch Cord-2 Meter- (DBPS Mounting Cord) Nos. Nos. SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 4 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT C. CABLES, MAINS & SUBMAINS 1 RM 15.0 0.00 RM 45.0 0.00 RM 70.00 0.00 RM 45.00 0.00 RM 40.00 0.00 D. DISTRIBUTION BOARD Supplying all materials and laying/ pulling 1100 volts grade PVC insulated copper conductor wires (FRLS) in MS conduit with all fixing accessories after cutting the floor, wall and the like etc. and replastering the floor level to original. Conduit must be 30 mm below the floor finish level. i 2 X 10 sq.mm. + 1 X 10 sq.mm. (Branch UPS Output DB) ii 2 X 6 sq.mm. + 1 X 6 sq.mm. (UPS Input/ Output, ATM Output DB) iii Supplying, laying, testing & commissioning of 4 C X 10 sq.mm. at 1100 volts grade PVC insulated aluminium conductor armoured cable with 10 gauge earth copper wire including cables end termination using appropriate Lugs, Glands, termination acessories, Clamps etc. as required as per specification (LIGHT DB, UPS Input DB for Branch and ATM). iv Supplying, laying, testing & commissioning of 4 C X 16 sq.mm. at 1100 volts grade PVC insulated aluminum conductor armoured cable with 10 gauge earth copper wire including cables end termination using appropriate Lugs, Glands, termination acessories, Clamps etc. as required as per specification (for Power & AC DB). v Supplying, laying, testing & commissioning of 3.5 C X 50 sq.mm. at 1100 volts grade PVC insulated aluminum conductor armoured cable including cables end termination using appropriate Lugs, Glands, termination acessories, Clamps etc. as required as per specification (for Main Connection). Supplying, installing, testing & commissiong of surface/ recessed mountings, Double door 415 volts TPN MCB distribution board of steel steel, 1.6mm thick dust phosphatized and painted, inclusive of 100 amps, tinned copper busbars, earthbar, common neutral link, din bar for mounting of MCB's detachable gland/ knock out plate & with built in loose wire boxl, and superior make terminal connectors for all incoming and outgoing circuits duly prewired with adequate size of PVC insulated copper wires between the bus bars and the MCB's as well as the incomer and upto the terminal connectors/ neutral link and ready for installation of following ways as required. SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 5 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT Inside each DB, a DB chart is to be fixed. a 6-way TPN DB (LIGHT DB & 6A RAW) No. 1.00 0.00 Incomer:- Outgoing:- 4-way TPN DB (16A RAW POWER DB) No. 1.00 0.00 Incomer:- Outgoing:- No. 1.00 0.00 4-way VTPN DB (AC) No. 1.00 0.00 Incomer:- 1 No. 63 Amp TPN 4 Pole (16KA) MCCB Outgoing:- No. 1.00 0.00 12-way SPN DB (For UPS OUTPUT) No. 1.00 0.00 Incomer:- Outgoing:- No. 1.00 0.00 No. 1.00 0.00 Incomer:- Use 'B' curve MCB's for lighting & small power circuits, 'C' curve for motor duty i.e. for pumps, AC motors, window and split AC's etc. & 'D' curve for UPS DB's i.e. for computers/ PC's circuit. Main incomer & outgoing circuit MCB's shall be selected accordingly i.e. type B,C & D. Contractor to select the MCB's accordingly as per the nature of the circuit/ load. Each DB shall have separate neutral links of rating not less than 100A for each phase. The main incoming neutral link shall be in addition to three outgoing neutral links and shall be of 125 A. UPS DB's shall have a dedicated Earthing link fixed on insulated supports, which will be in addition to body earth link. All internal inter connecting wiring with in the DB's shall be PVC insulated flexible copper conductor wires of adequate capacity as per the current rating. 1 No. 40 Amp TPN (10 KA) MCB with 40 A DP RCCB (100 MA) each phase 12 Nos.10/20 Amp (10 KA) SP MCB b 1 No. 63 Amp TPN (10 KA) MCB with 40 A DP RCCB (100 MA) each phase 6 Nos.10/20 Amp (10 KA) SP MCB c 8-way SPN DB (For UPS INPUT) with 1 Nos. 63 A TPN MCB as incomer and 2 Nos. 40 A DP MCB outgoing d 2 Nos. 32 Amp (10 KA) TP MCB 6 Nos. 25/32 Amp (10 KA) SP MCB e 2-way SPN DB with 40 A DP MCB (For UPS Input/ output) f 1 No. 40 Amp DP (10 KA) MCB with 40 A DP RCCB (100 MA) 8 Nos.6/10/16 Amp (10 KA) SP MCB g 4-way SPN DB (For UPS INPUT) with 1 Nos. 40 A DP MCB as incomer and 1 Nos. 40 A DP MCB outgoing h 8-way SPN DB (For E - Lobby) double door DB with lock & key arrangement SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 6 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT Outgoing:- No. 1.00 0.00 Incomer:- Outgoing:- E (LIGHT FITTINGS & ACCESSORIES) 12.00 0.00 35.00 0.00 5.00 0.00 12.00 0.00 4.00 0.00 4.00 0.00 13.00 0.00 4.00 0.00 F. 1 No. 40 Amp DP (10 KA) MCB with 40 A DP RCCB (100 MA) 4 Nos. 6/10/16 Amp (10 KA) SP MCB i 6-way SPN DB (E-Lobby UPS Sub DB) double door DB with lock & key arrangement 1 No. 25 Amp DP (10 KA) MCB with 25 A DP RCCB (100 MA) 2 Nos. 6/10/16 Amp (10 KA) SP MCB Supplying, installation with hanging support, testing and commissioning of following light fixtures with electronic Ballasts, Tubes, lamps, all fixing materials including connecting wires etc. all complete as per the directions of Engineer-in-charge (All LED Light Fixures should be covered with minimum 1 Years onsite replacement warranty). i FULL GLOW 2 X 2 LED 36 W slim Smart Panel of make As specified in tender document or approved by SBI/ Architect. Nos. ii Supplying, fixing, testing and commissioning of 15 W LED commercial type down lighter of make As specified in tender document or approved by SBI/ Architect. Nos. iii Supplying, fixing, testing and commissioning of 20 W LED T 8 fitting make As specified in tender document or approved by SBI/ Architect. Nos. iv LED Strip for cove lighting (in tube) 15 W per 5 M with driver and necessary installation supporting fittings of Led strip light (5 mtr.) make as specified in tender document or approved by SBI/ Architect. Nos. v Supplying, fixing, testing and commissioning of recessed LED Profile Light Axeon 30 W (4 ft long) with plain diffuser suitable for continuous/ seemless connection of make Wipro/ as specified in tender document or approved by SBI/ Architect. Nos. vi Supplying, fixing, testing and commissioning of 15 W extended body surface mounted COB light fitting/ drum light of make as specified in tender document or approved by SBI/ Architect. Nos. vii Wall mounted fans 400/450 mm dia. make As specified in tender document or approved by SBI/ Architect. (METAL BODY) Nos. viii Supply & fixing of PVC exhaust fan with auto opening louvers and all accessories etc. complete of make As specified in tender document or approved by SBI/ Architect. Nos. EARTHING SYSTEM SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 7 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT 1 1.00 0.00 2 2.00 0.00 3 RM 65.00 0.00 1.00 0.00 G. MAIN PANEL AND METER BOARD 1 1.00 0.00 2 Supply, Installation, Testing and Commissioning of Maintenace Free Earthing system made up of copperbonded rod of 10 feet length, 23 mm dia. (Minimum copper bonding shall be 0.25mm) along with Rod-toConductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bill). Nos Supply, Installation, Testing and Commissioning of Maintenace Free Earthing system made up of copperbonded rod of 10 feet length, 17.2 mm dia. (Minimum copper bonding shall be 0.25 mm) along with Rod-toConductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bill). Nos Providing and fixing of Copper/ GI strips in surface or in recess for loop earthing etc. as required. i Providing and fixing 2 X 8 SWG dia. Cu earth wire in PVC conduit on surface or in recess for loop earthing along with the existing surface/ recess cable as required eith using of copper lug at end termination ii Providing and fixing G.I. earth link with insulator and 10 nos of nut, bolt, washer, and spring washer for earth wire connecting in UPS room. Nos. supply, installation, testing and commissionings of cubicle type floor/ wall mounted L.T. Metal D.B of reputeded make with extendeble rotary handle and extended connecting links 1 No. 100 Amps, TPN MCCB (25 KA) with standard enclosure as per manufacturer specification or as approved by the architect/ Bank's Engineer Nos. Designing, fabrication, supply, installation, testing and commissionings of front operated cubicle type compartmentalised, front access, free standing on 75MM "[" MS channel, dust and vermin proof (IP 42 degree protection) panel suitable for use at 415V, 3 phase, 4-wire 50Hz system suitable for fault level of required value symmetrical at 415V fabricated from 2 mm thick CRCA MS sheets with hinged, gaskettted (Metal based neoprene) locable doors having structural reinforcement including 3 mm thick gland plates on top and bottom, lifting hooks, GI earth strip of required size with 2 nos earth terminals, 2 nos 230V AC operated 250 mm X 250 mm size axial fans for exhaust of heat with On-Off toggle switches including 2 coated primer and 2 power coated paint fnish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications as required.main panel board of approved make SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 8 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT a. Floor panel shall consists of : - INCOMER BUSBARS INDICATING PANEL OUTGOINGS:- Type of Approval as instructed by the SBI/ Architect). All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves SMC/ DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be locable in OFF position. Suitable arrangement shall be made for termination of multiple incoming cables. All kA values indicated shall be Ics breaking capacity GA drawings shall be got approved by Architect / SBI 1no. 100 Amp 4P On Load Changeover switch with 1 no. of 100 A TPN MCCB (25KA) with extandable rotary handle each 125 amps TPN busbar chamber of suitable length with copper busbars. One set of TPN BUS BAR for Main Raw Power DB and other TPN Bus bar for interconnection of below outgoing supply interlinked with DG set. All busbars and interconnections shall be of suitable size copper strips. Digital flush type class-1.0 accuracy multifunction meter showing V, A, PF etc. with 3 Nos. current transformers of 100/5A ratio, 10 VA Class-1.0 metering. - 1 sets Red/Green/Amber ON/ OFF/ TRIP indicating lamps with 2A SP MCB backup protection 1 set of three phase indicating lamps along with 2A SP MCB backup protection Restricted Earth fault relay with 3 Nos. current transformers of 100/5 ratio, 10 VA Class 5P 10 (Numeric Relay not required) 4 Nos 40 A DP MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars (For Signage, ATM DB, Spare). 3 Nos 63 A TPN MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars. (For UPS Incomer DB, Power DB, Spare) 1 Nos 40 A TPN MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars. (Light DB) 2 Nos 63 A 4 pole MCCB (16 kA) terminals suitable to receive cable on one side and wire connection to Bus bars. (For AC DB & Capacitor Panel) (b) Supplying, installation, testing & commissioning of 15 KVAR, APFC Panel autooperation and power factor should be nearing unity complete as required inluding all contactors, relays, indivating units etc. as required at site". Capacitor make: L&T/ ABB/ Siemens/ Neptune 8 nos. of capacitor duty contactors SBI Chaman Vihar Branch, Dehradun Geotech Technical Associates Pvt. Ltd. 9 S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT Set 1.00 0.00 H PUBLIC ADDRESS SYSTEM 1 5.00 0.00 2 a. Ceiling Speaker Unit 6 Watts 5.00 0.00 1.00 0.00 TOTAL FOR ELECTRICAL & ALLIED WORKS 0.00 1 Nos. 5 KVAR MPP type heavy duty capacitor banks along with 1 Nos. 16A TP MCB of 10 KA service breaking capacity with heavy duty solid detachable neutral link 4 Nos. 2 KVAR MPP type heavy duty capacitor banks along with 2 Nos. 10A TP MCB of 10 KA service breaking capacity with heavy duty solid detachable neutral link 2 Nos. 1 KVAR MPP type heavy duty capacitor banks along with 1 Nos. 10A TP MCB of 10 KA service breaking capacity with heavy duty solid detachable neutral link The electrical panel as described above and specifications complete. Point wiring for speakers in 1.5 sq mm twin core shelded type of speaker cable with Providing and fixing in position the following FRLS PVC conduits including all accessories concealed/exposed in F.Ceiling/Wall complete as required including 1.6/2.0 mm thick PVC junction or pull boxes with 3mm thick perspex sheet cover plate complete with 1.6 mm dia G.I. pull wires in the length of conduit. including all accessaries. Nos. Supply, installation, testing and commissioning of following Philips/Bosch/Ahuja make Music Accessories/ Equipments. Nos. b. Power Amplifier, min 30/ 50 Watts with output transformer etc. complete. Plena Range/ Ahuja or as approved by the Bank capable of taking Inputs from USB Als
|