Tender For Airconditioning Works Of Acb Dharur Branch Preambles 1 All Items shall be quoted in the given format. 2 Client reserves the right to take any item as client supplied 3 4 Boq items shall be read with the technical specifications 5 6 7 It is advice to visit the site before quoting the boq 8 9 10 11 12 13 Treated fresh air unit shall be considered with MERV 13 pre filter 14 15 16 1 DX VRF OUTDOOR UNITS : Client reserves the right to add or delete any item from the tender during or after the finalization of the tender. In case of discrepancy in Boq and technical specifications the stringent shall be followed. Control cable from outdoor unit to indoor unit (condenser to evaporator) with necessary insulating tape etc. MS Powder coated bracket with fasteners to be fixed on walls / slab with all necessary fixing accessories ALONG WITH ANIT VIBRATION CUSHOR FOOT MOUNTING ONLY. The Items in the Boq may or may not be operated as per site conditions. Any deviation with respect to boq shall be informed and mentioned while quoting TENDER. Insulation shall be done properly with vapour barrier and to provide mechanical protection against abrasion. Indoor unit shall be considered with required structural support to hang in ceiling or floor / loft with anchor fasteners, rubber gaskets, nuts, bolts, inlet outlet connections Copper piping shall be considered with T and Y joints with insulation. All AHUs except VRF ductable unit shall be DX type unless otherwise mentioned. Any item missed in the tender for competing the installation, testing, commissioning of the complete HVAC system all also to be included. CARRIER / BLUE STAR / HITACHI / TOSHIBA / MITSUBUSHI / DAIKIN -VRF UNITS : FULLY INVERTER ONLY :- Supply Installation, commissioning & testing of VRF Multi- split systems as specified and complete with the following and suitable for cooling Sheet1 Page 2 d) with Required cowl piece on fan discharge. 1.1 Sets 1 2 2.1 FOUR WAY COMPACT CASSETTE AC's VRF Indoor Units : a 2.0 TR Capacity Four Way Cassette AC Nos 5 c 1.5 TR Capacity hi wall Split AC Nos 1 3 SITC of Centralise digital screen remote controller Sets 1 4 SPLIT AC's NON VRF Indoor Units : a Nos 2 TOTAL BASIC COST S.No Description Unit Quantity APPROX. INSTALLATION BREAK UP 1 1.1 6.4 to 31.05 mm RMT 90 1.2 RMT 10 2 RMT 80 3 RMT 14 4 RMT 60 5 Hard UPVC Drain piping for Non VRF AC Units RMT 8 a) Outdoor units complete with DC Twin rotary compressors / FULLY DIGITIAL BASED SCROLL COMPRESSOR with atleast 2 x 100% inverter compressors cooling only etc as specified latest technology fully inverter based compressor. Each Outdoor Unit will require minimum 2 Nos. Fully Inverter Compressor Only. b) Environmental friendly refrigerant. (HFC) : R410 REFRIGERANT GREEN GAS c) The required distribution board with required isolators to supply power two both ODU in a MS fabricated & Powder Coated Enclosure of IP 65 Protection with weatherproof canopy. VRF Modular Type Outdoor unit 14 HP Top discharge : Space Saver Compact Model ONLY. VRF INDOOR UNITS : Indoor units of types mentioned below complete with Panel - Grill, cordless remote controller, mounting arrangements, drain pump etc. 1.5 TR Capacity Hi Wall 5 star split AC with minimum 3 mtrs Copper pipe and 5 mtr control cable etc as reqd. Hard Copper Piping with 19mm thick nitrile rubber "O" Class insulation and necessary supports : minimum 18 G Hard COPPER PIPES Make Of Copper Pipes : Mandev / Rajco / Max Flow / Totaline Only & With "O" Class 19 mm thick Insulation make "Superlon / Armaflex" : Piping material shall Confirm to ASTM B280 Standards : For VRF System as per following dimension : Copper piping for non VRF Split AC Units(suction and liquid) i/c all accessories Control Cabling between Indoor & Outdoor Units (3 CORE X 1.5 SQMM SHEILDED CABLE ) CABLE MAKE "POLYCAB / FINOLEX." - Laid in Conduits Pipe Only. Control Cabling between Indoor & Outdoor Units for Non VRF Split Acs Hard UPVC Drain piping with 6 mm Rubber Nitrile Class "O" Insulation Make "Plasto/ Supreme" 32 mm dia. Sheet1 Page 3 6 RMT 25 7 Nos 1 8 Nos 2 8 Installation, Testing & Commissioning Of Non VRF AC Units a 1.5 TR Capacity Split AC Nos 2 9 9.1 14 HP OUTDOOR UNITS. Sets. 1 10 a 3.0/2.0 TR Capacity Four Way Cassette AC Nos 5 b 1.0/1.5 TR Capacityhi wall splitAC Nos 1 11 Nos 5 12 SITC of digital timer i/c all necessary accessories etc as reqd. Nos 1 13 Lifting Shifting of Indoor & Outdoor Units On Terrace Lavel. LOT 1 14 Nos 0 15 Nos 0 16 TR 12 TR 12 TR 12 TR 12 TR 12 Supply & Laying of 300 mm Width GI Tray fabricated with 16 G Thick perforated sheet for laying of copper piping / electrical cabling / drain piping etc. MS stand for Outdoor Units WITH PROVISION OF ANTI VIBRATION CUSHOR FOOT MOUNTING FOR MACHINE & Hanging Stand For Indoor Units with required MS frame arrangements only : MS "C" Channel Structure Type as per site requirement only - Fabricted with MS "C" Channel only & fabricated hanging stand for Indoor Units, DX Units for mounting of independent Outdoor units as require. MS Powder coated bracket with fasteners to be fixed on walls / slab with all necessary fixing accessories ALONG WITH ANIT VIBRATION CUSHOR FOOT MOUNTING ONLY for Non VRF Split AC Units Standard Installation / Pressure Testing / Vaccumissing / Commissioning Leak Testing of Outdoor Machines for inverter Compressors complete with provisiong of anti-vibration isolators pads for complete machine etc. Installation, Testing & Commissioning Of Cassette AC's Type VRF Indoor Units : Supply & Fixing Of Refrigerant Joints as per company STD. material for VRF units only. Dismantling of Existing cassette AC Units along with all accessories, Indoor units, outdoor units, Copper pipes, stands, Control cablies etc including Buying back of above all and transporting etc as reqd. Dismantling of Existing Split AC Units along with all accessories, Indoor units, outdoor units, Copper pipes, stands, Control cablies etc including Buying back of above all and transporting etc as reqd. Providing Comprehensive annual maintenance for Airconditioning units which includes servicing and repairing of all the Airconditioning units by predefined frequency. The AMC Period will start after completion of 1 year warranty period. For 1st Year For 2nd Year For 3rd Year For 4th Year For 5th Year Sheet1 Page 4 17 Tonnes 15 TOTAL BASIC INSTALLATION COST TOTAL PROJECT VALUE (EXCLUDING GST) SUPPLY + INSTALLATION (A+B) Providing Comprehensive annual maintenance for Airconditioning units which includes servicing and repairing of all the Airconditioning units by predefined frequency. The AMC Period will start after completion of 1 year warranty period.
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 105938752
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.