|
Tender For Construction of second floor construction work in Hospital Ward 106 Collector Ganj Dhankutti operated by Nagar Nigam under Arya Nagar Vidhansabha.- 1 Centering and shuttering including strutting, propping etc. and removal of form for : 2 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers DSR 5.9.5 3 (c) Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 4 (d) Suspended floors, roofs, landings, balconies and access platform.DSR 5.9.3 5 R.C.C 1:1.5:3 in Column with cement coarse sand and stone grit …. Complete item.DSR No.5.2.2 6 R.C.C 1:1.5:3 in Beam with cement coarse sand and stone grit …. Complete item, DSR No.5.3 7 R.C.C 1:1.5:3 in Slab with cement coarse sand and stone grit …. Complete item. 8 M.S (Tor steel or plain ) in plain work such as R.C.C or R.B work including cutting / bending for proper shape as necessary including supply of all steel & wastage ,bend ,hook & authorised overlapping shall be measured … complete item. DSR 5.22.1 9 M-150 Brick work in 1:6 cement Coarse sand in superstructure …. Complete itemDSR No.6.4.2 10 M-150 Brick work in 1:4 cement Coarse sand in superstructure …. Complete item.DSR No.6.4.1 11 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) DSR 10.15.1 12 P/Fixing of 100mm PVC RWP down pipe with clamping and bend shoes etc …. Complete. ( S.I-730a, miscellaneous ) 13 Point Wiring : 14 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 15 Group C 16 Submains : 17 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 18 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 19 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 20 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 21 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 22 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 23 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 24 MCB"s & DB’s : 25 Supplying and fixing following 8 way, SPN Dustribution Box sheet steel, MCB distribution board, on surface/ recess, complete 26 6 way SPN , Double door 27 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 28 Single pole 29 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 30 Earthing Work : 31 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 32 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 33 Lighting Fixtures (Lights/Fans) : 34 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter having Powder coated die cast aluminium housing with heat sink , diffuser /reflector and driver set complete in all respect.CAT. - AAA 35 Supply and Erection of 100 amp TPN tap off box on rising mains complete with HRC fuses etc. complete in all respect (sch. Nos.. 914) Please Enable Macros to View BoQ information
|