Tender For Various Sanctioned Works At Age B/R Iii Under Ge Shillong - Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified. 2 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed 3 Taking down old defective chowkhats with shutter (without taking off shutters from the frame) n.exc 1.5 sq.m eachand removing away from site, complete all as specified and as directed. 4 Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) and complete all as specified and as directed. 5 Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed. 6 Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed. 7 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall clading fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 8 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed. 9 S & F of 20mm thick, second class hard wood boarding,plane on one side with butt joints and fixed complete in position as in eaves board, etc. complete allas specified and directed. 10 M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and as directed. 11 M & L for anodised aluminium snap grid frame work for false ceiling of size 605 mm x 605 mm in true horizontal level complete all as specified and as directed. 12 M & L for 4 mm thick prepainted designer fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building E boards 600mmx600mm, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture , fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified and directed. 13 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 14 M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed. 15 M&L for Glazed ceramic tiles on vertical surface of size 450X 350X 7-8mm or 300x200x7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of the tiles laid over and including 10mm thick rendering as backing coatin CM 1:4 with wire markings to receive tile over it, complete all as specified and as directed. 16 M&L vitrified ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to matchin floor including15 mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. 17 M & Lvitrified ceramic tiles light shade 9 to 10mm thickarea of each tile notexceeding 0.36 sqm, in skriting dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. 18 M&L for dark shade vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tile, laid over and including 15mm thick screed bed in CM 1:4, complete all as specified and as directed. 19 M&L for dark shade vitrified ceramic tiles 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in vertical surface such as skirting, dados, risers to steps, etc.,setand jointed in neat cement slurry and pointed in white or colour cement to match colour of tile, laid over and including 10mm thick rendering as backing coatin CM 1:3 with wire markings to receive tile over it, complete all as specified and as directed by Engineer-in-charge at site. 20 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick finished even and fair complete all as specified and directed. 21 M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection and making 50mm deep joints at every 3 mtr enterval and at every corners and filling the joints with bitumen grade 85/25 and sand mixture 1:3 complete all as specified and as directed. 22 M&L for 20mm thick granite (of any type), work in cooking platform, in toilets for fixing wash hand basin, counter slab (table rubbed and polished), in steps, jambs, pillars, window cills and like, fixed in cement mortar 1:4 including pointing in white cement 1:2 using granite / marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement screed in CM 1:4, complete all as specified and as directed. 23 M & L for chamfer, splays or arris in face work not exceeding 15 mm wide on granite or trap stone complete all as specified and as directed. 24 M & L for powder coated (colour) aluminium frame for doors, windows, ventilators (thickness of powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing including handle, tower bolt, door stopper, grills etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. 25 M & L for powder quoted (colour) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed. Note:- Design/ pattern, profile sizes and other dimensions shall be of standard size and as directed. 26 M & L for powder coated (powder coating min 50 micron) Anodised aluminium window andventilator shutters, side hung typewithout sash bars, aluminium sectionsweighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) completeallasspecified and directed. 27 S & F prelaminated particle board (decorative lamination on both sides), 12 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWR adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in table tops, counter, furniture tops, etc. complete all as specified and as directed. 28 Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square exceeding 0.5 Sqm in each pane complete all as specified and directed. 29 S & F solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed. 30 S&F 2nd class hardwood plain, solid, straight chowkhats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and as directed. 31 S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed. 32 MSupply and fixing 2nd class HW 35mm thickGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares(without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed. 33 S & F 1 mm thick, type S (Standard type), wear index No. 3, Impact Index No. 2, Scratch Index No. 3, one side decorative, laminate as per IS 2046: 1995 of surfaces finish, colour and pattern as per approved, fixed with approved adhesive as per manufacturers instructions complete all as specified and directed by Engineer-in-charge. 34 S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. 35 Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 36 S & F hot rolled medium and high tensile structural steel (Fe-410 of grade 250, quality B conforming to IS 2062: 2011) as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. 37 S & F prelaminated particle board (decorative lamination on one side and other side balancing lamination), 20 mm thick, grade I or II & type II (Designation PLB-12 or PLB-22), made out of medium density particle board (flat pressed-three layer or multilayer and graded (grade I or grade II), bonded with BWP adhesive), fixed with screws to timber/ steel frame work for horizontal applications as in table tops, counter, furniture tops, etc. complete all as specified and as directed. 38 S & F mild steel continuous hinge, 30 mm nominal size, 1 mm thick, type IV as per IS 3818: 1992, bright finish and fixed to cupboard shutter complete all as specified and directed. 39 S&F Magnet catches for cupboard shutter, brass body and striking plate including letting in all as specified and as directed. 40 Supply and fixing of solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed. 41 S & F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with particle board core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. 42 S & F 100mm butt hinges, Butt hinges, extruded aluminium alloy with galvanisedmild steel hinge pin, anodisedand fixed, type B-21 complete all as specified and as directed. 43 S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 44 S & F extruded aluminium alloy handle, fabricated type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 45 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 46 S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. 47 S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 48 S & F brass alloy handle, fabricated type, 100 mm size, nickel chromium plated finish as per service grade number 2 of IS 1068: 1993 complete all as specified and as directed. 49 S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed. 50 S&F in repair PVC (SWR) Pipes single socketed in any length with rubber ring joints, 110 mm bore fixed to walls/floor, complete all as specified and as directed. 51 S&F in repair PVC(SWR) pipes 75mm dia single socketed in any length with rubber ring joints fixed to walls/floor complete including clamps for securing pipe, complete all as specified and as directed. 52 S & F of PVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. 53 S & F of PVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. 54 S&F PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed. 55 S&F in repair brass chromium plated tubular towel rail 20mm dia complete all as specified and directed. 56 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 57 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. 58 Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 59 Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 60 S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws) including 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, waste pipe and painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. 61 S & F in repair of mild steel brass chromium plated health faucet (ABS body) for 15mm bore pipe and 1.25m long and flexible tube and ABS wall hook including making connection and fixed in position complete all as speified and directed. 62 S & F in repairs vitreous china wash down water closet pan (Pedestal pattern) with P or S trap white (excluding flushing cistern and flush pipe) including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor, complete all as specified and as directed. 63 S & F in repairs in repairs 10 litres capacity, low level, syphonic type, white, pressed steel (vitreous enamelling) flushing cistern as per IS 774: 2004 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. 64 S&F bib taps with wall flange, fancy type, quarter / half turn, chromium plated, long body with capstan head and cup, screwed down, screwed for iron pipe or for brass ferrule including accessories, suitable for bore of pipe 15 mm, complete all as specified and directed. 65 S & F 15 mm nominal size, nonrising spindle type fancy concealed stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 66 S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. 67 M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 68 S&F in repair PVC bathroom mirror cabinet of size 622x422mm complete all as specified and directed. 69 S & F in repairs sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed. 70 S & F in repairs 15 mm dia brass CP centre hole basin mixer for mixing hot & cold water screwed down for iron pipe and fixed as in repairs. 71 S & F Kitchen stainless steel plate rack 1 mm thick of size 31 X 30 X 10including necessary fixing / fittings & making good the existing surfaces complete all as specified and directed. 72 S & FIN REPAIRS,wall mixer with and including over head shower with 115 mm long bend pipe on upper side, connecting legs and wall flangescomplete all as specified and as directed. 73 S & F of 15 mm dia brass CP sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. 74 S & F in repairs chromium plated soap dish fancy type oval shaped fixed with brass screws complete all as specified and as directed. 75 S & F in repairs 20 mm dia harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. 76 S & F wooden brackets with wooden finish for 20 mm dia single rod, rollers etc complete all as specified and as directed. 77 S&F of wooden finials with wooden finish complete all as specified and directed. 78 S&F in repair peg set of six chromium plated, back plate including chroomium plated fixing screws complete all as specified and directed. 79 Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demolition) and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. 80 M & L for precast RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) complete with joints to match complete all as specified and as directed. (Note: Reinforcement shall be measured and paid seperately) 81 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height complete all as specified and as directed. 82 Cutting chases in stone, concrete block walls & slabs to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., not exceeding 10 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed. 83 S & F in repairs 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete 84 S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed. 85 S & F in repair 20 mm nominal size brass ball valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed. 86 Demolition of ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 87 M & L for precast cement concrete solid block masonry of grade C(5.0) with concrete M 10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate exceeding 10 cm in width and set in cement mortar (1:6) complete all as specified and as directed. 88 M & L for precast cement concrete solid block or slab 10 cm thick (with plain or interlocking joint as directed) as per IS 2185 (part-1): 2005, masonry of grade C(5.0) with concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, and set in cement mortar (1:4) complete all as specified and as directed. 89 M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 90 M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. 91 Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed. 92 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed. 93 Material and labour for plastering 15 mm thick (in two layers of 10mm and 5mm thk) on fair faces of brick wall or concrete surfacesin cement mortar 1:4 with water proofing compound as per manufacturers printed instruction finished even and fair complete all as specified and directed. Note: Water proofing compound shall be measured and paid for separately. 94 Supply only integral water proofing compound complete all as specified and directed. 95 M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of suitable primer with auto roller over 1 mm thick putty to match the surfaces complete all as specified and as directed. 96 M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over a coat of suitable primer with auto roller over 1mm thick wall care putty complete all as specified and as directed. 97 M&L for preparation of old painted surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint, white or tintedcomplete all as specified and as directed. 98 Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour complete all as specified and directed. 99 Material and labour for waterproof cement based putty @ 1 Kg (undiluted) per sqm of average thickness 1 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturers instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat of the prepared mix with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. Step3) Allow 6-8 hrs time to dry the putty surface.NOTES :- (a) The work pertaining to periodical services & Water Proofing shall be executed by authorized applicator through manufacturer of which the materials i.e. Paint, Distemper,Putty etc. is proposed to be used by the contractor and approved by GE. (b) The cost of scaffolding upto 10m height of building shall be included in the quoted rate. (c)The contractor shall upload MOU letter with any one of manufacturer and also with their authorised applicator mentioned in the tender alongwith their bid in cover-I failing which his bid will be rejected. Authorised applicator shall have valid authorisation letter from the manufacturer (Minimum regional HQs) and shall have been issued not less than 30 days from the date of commencement of the work.The authorisation letter needs to be valid for the complete period of execution of the painting work. (d)After preparation of the surface, Engr-in-Charge shall approve the same before applying primer and finishing coats. (e) Building wise stage passing register shall be maintained and shall be signed by Engr-in-Charge and contractor. (f) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. (g) Contractor shall submit approved company generated 05 years warranty card at the time of submission of RAR & Final Bill. 15% amount of this item will be retained in FB for a period of 05 years from the certified date of completion. (h) Masking of windows / doors during spray painting using polythene film is inluded in the quoted rates. (j) Cleaning and clearing of site of painting, mats etc after completion of work is included in the quoted rate. 100 M&L for applying two or more coats of 100% Premium acrylic emulsion paint havingVOC less tham 50 gm/ltrs and UV resistance as per IS 15489:2004, alkali and fungal resistanxe dirt resistance exterior paint of required shade with silicon additives @1.43 ltrs/10sqm over and including priming coat of exterior primer applied @0.90 ltrs/10 sqm over new surfaces complete all as specified and directed. Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paintapplication).NOTES :- (a) Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paintapplication).(b)The work pertaining to periodical services & Water Proofing shall be executed by authorized applicator through manufacturer of which the materials i.e. Paint, Distemper,Putty etc. is proposed to be used by the contractor and approved by GE. (c) The cost of scaffolding upto 10m height of building shall be included in the quoted rate. (d)The contractor shall upload MOU letter with any one of manufacturer and also with their authorised applicator mentioned in the tender alongwith their bid in cover-I failing which his bid will be rejected. Authorised applicator shall have valid authorisation letter from the manufacturer (Minimum regional HQs) and shall have been issued not less than 30 days from the date of commencement of the work.The authorisation letter needs to be valid for the complete period of execution of the painting work. (e)After preparation of the surface, Engr-in-Charge shall approve the same before applying primer and finishing coats. (f) Building wise stage passing register shall be maintained and shall be signed by Engr-in-Charge and contractor. (g) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. (h) Contractor shall submit approved company generated 05 years warranty card at the time of submission of RAR & Final Bill. 15% amount of this item will be retained in FB for a period of 05 years from the certified date of completion. (j) Masking of windows / doors during spray painting using polythene film is inluded in the quoted rates. (k) Cleaning and clearing of site of painting, mats etc after completion of work is included in the quoted rate. 101 Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position 102 Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position complete all as specified and directed. 103 M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn in scantlings and timber fixed complete all as specified and as directed. 104 M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. 105 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 106 S & F hot rolled medium and high tensile structural steel of gradeFe 410-W (Gde E- 250)quality A conforming to IS 2062: 2011 as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. 107 M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed. 108 Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M40 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape with grey cement and no pigment complete all as specified and directed. 109 M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. 110 Surface dressing not exceeding 15 cm deep in soft/ loose soil and removal of spoil outside MD land complete all as specified and as directed. 111 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed. 112 M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 113 M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished flat surfaces of concrete complete all as specified and as directed. 114 M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed. 115 M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed. 116 M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed. 117 M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and as directed. 118 M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. 119 M & L for mild steel TMT bars 5 mm dia and over, upto and including 10mm dia as in stirrups, spaces and binders bent to shape as required including cranking, bending and binding with mild steel wire (annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed. 120 M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. 121 M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. 122 M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. 123 M & L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 124 M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed. 125 M & L for treating the bottom and sides of excavation at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed. 126 M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of vertical surface complete all as specified and as directed (Area of the sub structure in contact with backfill to be measured). 127 M & L for treating the top surface of filled earth at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface complete all as specified and as directed. 128 M & L for treating the soil under plinth protection at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed. 129 M & L for treating the soil along with external perimeter of building at the rate of 2.25 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per metre of the perimeter wall complete all as specified and as directed. 130 M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed. 131 Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. 132 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 133 M&L for preparing newly plastered surfaces of ceiling andapplying three coats of whitewash complete all as specified and as directed. 134 M & L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over alkali resistant primer complete all as specified and as directed. 135 M & L for preparation of newly plastered surface of wall and applying two coats of distemper oil emulsion with auto roller for making the surface uniform over one coat of suitable primer complete all as specified and as directed 136 M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, wrought in scantlings and timber framed and fixed complete all as specified and as directed. 137 M & L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler liquid transparent on new work with two or more coats complete all as specified & directed. 138 Supply & fix sheet glass, ordinary quality, 5.5 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. 139 S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile D, double rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed. Note- PCC filling of hollow section shall be measured and paid seperately. 140 S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed. 141 S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed. 142 M & L for preparation of surfaces of wood and wood based materials, steel and iron work, new or old e.g. ends of posts, backs of chowkhats, etc. area tarred not exceeding 0.10 sqm and treating with tar or coal tar black paint complete all as specified and as directed. 143 S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified and directed. 144 S&F 35mm thick, 2nd class hard wood, Glazed andskeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), but divided into squares, with plain, chamfered or rounded,mitred and rebated sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats complete all as specified and as directed. 145 S & F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed. 146 S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed. 147 S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 148 S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. 149 M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. 150 M & L for hardcore (broken stone or boulders) of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 151 M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in dado , skirting and riser etc, set and jointed in cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed 152 S & F 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed. 153 M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top: (i) Screed bed or bedding layer of mortar 15mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement (WPC shall be measured and paid seperately) (ii) Cleaning the plastered roof surface and applying one coat of cold bituminuous primer @ 0.25 ltr/Sqm confirming ti IS: 3384 -1986 (iii) APP based polymeric menbrane 3mm thick (minimum) weighing 3.5 kg/Sqm reinfiorced with polyster non woven fabric (weighing not less than 160gms/Sqm) shall be less appliedb over bituminous primer as specified above over a application of polymeric membrane shall by torch application. The overlaps shall be minimum 100mm on the teransverese direction and 75mm on longitudinal direction 154 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 155 Removing excavated material (excluding hard rock) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 156 Dismantling timber scantlings in framed works, 40 sqcm and over in section, in any position 157 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed. 158 Dismantling posts or struts (wood, steel or RCC.) any section embedded in natural ground, including taking out embedded portion and making good disturbed ground 159 Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting angle iron, roof top MS sheets, railings etc. complete all as specified and directed. 160 Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed. 161 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. 162 M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. 163 M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. 164 M & L for cement concrete M10 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings etc. complete all as specified and as directed. 165 Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed. 166 M & L for cement concrete M10 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate 25 mm thick in pavings finished even and fair complete all as specified and as directed. 167 S&F of 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete as specified and directed in SSR Part I Section 8 clause 8.24 (b). 168 M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in flooring finished even and fair complete all as specified and as directed. 169 S&F of GI frame work for snapgrid false ceiling comprising of Gl perimeter channnel 0.55 mm thick with Main T- flange of 25 mm and web of 30 mm fixed to surrounding wall angle with flange and web 25 mm each, Cross T with flange 25 mm and web 25 mm fixed to main T, Main T is suspended from soffit @ 1200 mmm c/c using Gl wire of 4mm thickness GI frame will be 60 x 60 cm to recieve E-board ceiling complete all as specified and as directed. 170 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 171 M & L for point wiring for one light or one fan or one exhaust fan or bell point controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including PVC casing caping of suitable size as required as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 172 M & L for point wiring for one 3 pin/ 5 pin 6 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing caping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 173 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing caping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. 174 M & L for point wiring for one light or one fan or one exhaust fan controlled by one modular switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC concealed conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings etc. ISI marked for mounting of modular fittings, switches, sockets, regulators etc suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.Note:- Cutting chases and making good in CM (1:3) are deemed to be included in quoted rate. 175 M & L for point wiring for one 3 pin/ 5 pin 15 Amps modular socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings etc. ISI markedfor fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) 176 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 1.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 1.5 sqmm cable, one run of 1.5 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. 177 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through existing conduit/ casing/capping and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed. Note - Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of PVC casing caping shall be measured and paid as one unit length. 178 Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. 179 M&L for switch piano (flush button type) single pole one way 5 Amps complete all as specified and directed. 180 S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 181 S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and neon indicator and fuse complete all as specified and as directed. 182 S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 183 S&F of building security light fittings 35 watts, minimum system lumen output 100 lumen/ watt, made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP 65 including 40mm dia GI pipe of suitable length with nuts, bolts and clamps complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. 184 Taking down serviceable LED fittings/ energy meter /geyser/ ceiling fan/exhaust fans any sweep or any other fittings/ fixtures anddeposite in safe custody after repair work reinstall in original position after minor repair if any complete all as specified and as directed. Note: In case of damage of applliances during taking down or re- installation, contractor will be responsiblle for necessary repair and make the appliances in serviceable condition without any extra cost. 185 S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A-63A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 186 S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 12 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 187 S&F MCB, SP, 240 volts, 6-32 Amps 10 KA, C Curve, complete all as specified and as directed. 188 S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed. 189 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 15 mm dia GI pipe light grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing including taking down old earthing complete all as specified and as directed. 190 S & F modular switch socket combination, 3 modules with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 191 S & F modular white cover plate with frame, 3 modules complete all as specified and as directed. 192 S & F modular white cover plate with frame, 2 modules complete all as specified and as directed. 193 Supply and fix metal flush box 3 module complete all as specified and as directed. 194 Supply and fix metal flush box 1 or 2 module complete all as specified and as directed. 195 Supply and fixing 18 W LED light fitting wall mounted batten 4ft , extruded aluminium housing , enivromental friendly . heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt , 6000K including necessary connection complete all as specified and directed. 196 S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 2 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 197 S & F in repair MCB DP, 40 A, 240 V complete all as specified and as directed. 198 Supplying & laying, in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 199 Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. Note :- Only punned down sand shall be measured. 200 M&L for fly ash bricks locally available laid dry width wise across th line of cable for protection of UG cables complete all as specifed and directed 201 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
|