|
Supply Of High-Volume Long-Range Foam Cum Water Monitor (Hvlrm) For (Pfcc / Gds/ Ms Block) Unit For Nrep Supply Of High Volume Long-Range Foam Cum Water Monitor (Hvlrm) For (Pfcc / Gds/ Ms Block) Unit For Nrep , Supply Of High-Volume Long-Range Foam Cum Water Monitor (Hvlrm) For (Pfcc / Gds / Ms Block) Unit For Nrep (Overall Lowest On Landed Cost Evaluation) , Ul Listed / Fm Approved 1000 - 1500 - 2000 Gpm Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (Hvlrm), Stand Post Mounted, Manually Operated Type, Moc-Ss 316, 150 Mm Nb Flanged Inlet, Asme B 16.5 Cl. - 150, Ff, Including But Not Limited To Jet Ratio Comptroller Pump (Jrcp), Pick-Up Tube, 1 No. Ul Listed Foam Concentrate Container (Tote) Of 1000 Liters Capacity Filled With Ul Listed Afff 3% Foam Concentate,1 No.2-1/2 Dia Hose Of 15M Long For Connecting Jrcp With Monitor Nozzle For Foam Solution Supply To Monitor Nozzle, Monitor Nozzle Having Suitable Male Inletfor Foam Solution Induction Through Jet Ratio Comptroller Pump (Jrcp) Etc. As Per Attached Technical Specification For Fire Fighting & Safety Equipment (Tk-1Zzza-Sa-Dat-0001_A1). , Ul Listed / Fm Approved 1000 - 1500 - 2000 Gpmvariable Flow Capacity High Volume Long Range Water Cum Foam Monitor (Hvlrm), Tower Mounted And Remote Operated Type, Moc-Ss 316, 150 Mm Nb Flanged Inlet, Asme B 16.5 Cl. - 150, Ff, Including But Not Limited To Local Control Panel With Mounting Bracket And Canopy (1 No.), Wireless Remote Controller Unit Having About 75M Operating Range From The Local Control Panel (1 No.), 8 Size Motor Operated Gate Valve (Mov) With Actuator (1 No.) (Refer Attached Piping Material Specification For Technical Moc And Coating Details Of Gate Valve - Tk-1Zzza-Pi-Spe-0002_D2), Vertical Foam Concentrate Storage Tank (Ss 304) Of 1000 Lit Capacity Filled With 3% Afff Foam Concentrate (1 No.) Fabricated As Per Asme Code Section Viii, Div.-I With Built-In Canopy Fro Protecting From Direct Sunlight & Weather Conditions (1 No.), Pick-Up Tube Of Suitable Size And 4M Long To Suck Foam Concentrate From Foam Tank (To Be Kept Near The Monitor On Top Of The Platform) To Monitor Nozzle (1 No.), Limit Switch (1 No.) To Be Installed On The Foam Concentrate Tank And To Be Connected Through Cabling With Local Control Panel Of The Monitor For Monitoring Of Foam Concentrate Level In The Tank, All Required Junction Boxes, Power & Control Cable, Cable Trays, Cable Glands, Other Cabling Accessories Etc. Bidder Shall Consider The Cabling Distance Between Monitor (And Level Switch Also) On The Top Of Platform & Local Control Panel As About 200 M (Approx.) And The Cabling Distance Between The Local Control Panel And The Mov (At Ground Level) As 200 M (Approx.) Also And Supply The Cabling Accordingly. All Electrical & Instrumentation Items Of This Equipment Shall Be Suitable For Hazardous Area Classification Zone-1, Gas Group Iia/Iib/Iic, T3 As Minimum. Weather Protection For Control Panel Enclosure Shall Be Mini-Mum Ip65. Bidder Shall Refer The Scheme Of The Remote Operated Monitors In The Attached Technical Specification For Fire Fighting & Safety Equipment (Tk-1Zzza-Sa-Dat-0001_A1). Bidder Shall Note That The Foam Concentrate Tank Shall Be Located Near The Monitor On The Top Platform Of Structural Tower. Foam Concentrate Induction Shall Be Done From This Tank Through The Pick-Up Tube. The Tank Shall Be Designed And Fabricated As Per Asme Code Section Viii, Div.-I. The Tank Shall Be Fitted With Nozzle For Foam Concentrate Supply Inlet(2” Line) From Top, Nozzle For Pick-Up Tube Entry From Top, Nozzle For Vent Connection From Top, Nozzle Of Connecting A Level Switch From The Top And Nozzle For Drain Connection With Isolation Valve At Bottom. The Tank Shall Be Connected With A Rigid Piping (Ss 304) Of 3 Size For Refilling Purpose And Shall Be Routed From The Tank Filling Nozzle To The Ground Level Near Road Edge Fitted With A 1-Way Fire Brigade Connection Of Ss 303 Material. This Ss Piping Shall Not Be In The Scope Of Supply Of The Bidder. Bidder To Submit Separate Technical Data Sheet For The Tank Along With Their Offer. , 1-Way Fire Brigade Connection,With 1 No. 63 Mm Nb Male Instantaneous Inlet And 80 Mm Nb Flanged Outlet, Moc - Ss 304. , Afff 3% Foam Concentrate To Be Supplied With 200 Liter Capacity Drum, Ul Listed. , Spare Parts For High Volume Long Range Foam Cum Water Monitors (Hvlrm) (Pfcc / Gds / Ms Block) Unit For Nrep Project. , Spare Parts For Ul Listed / Fm Approved 1000 - 15000 - 2000 Gpm Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (Hvlrm), Stand Post Mounted, Manually Operated Type, Including The Following Items: , Rubber ‘O’ Ring Kit. (Recommended 02 Kits Per Monitor) , Pressure Gauge , Gland , Key For Worm , Grease Nipple , Spare Parts For Ul Listed / Fm Approved 1000 - 15000 - 2000 Gpm Variable Flow Capacity High Volume Long Range Water Cum Foam Monitor (Hvlrm), Stand Post Mounted, Manually Operated Type, Including The Following Items: , Rubber ‘O’ Ring Kit. (Recommended 02 Kits Per Monitor) , Pressure Gauge , Gland , Key For Worm , Grease Nipple , Limit Switches , Relay , Junction Box , Proxy Sensor , Push Buttons , Indication Lamp , Spare Parts For Motor Operated Valve (Mov) Including But Not Limited To Gland Packing, O-Rings, Bearings, Gaskets, Electronic Card For Actuator, Seat, Seat Ring, Maintenance Kit Etc. , Spare Parts - 1-Way Fire Brigade Connection,With 1 No. 63 Mm Nb Male Instantaneous Inlet And 80 Mm Nb Flanged Outlet, Moc - Ss 304. , Spare Parts - Afff 3% Foam Concentrate To Be Supplied With 200 Liter Capacity Drum, Ul Listed. , Site Supervision Services Rection/Commissioning Of Remote Operated Tower Monitors
|