|
Pre Bid Tie Up For 400Kv Gis For Powergrid Substation Package Ss 142T Niglok , Supply- Gis : 400Kv, 63Ka For 1S, Gas Insulated Switchgear (Gis) As Per Ts (For Item Sl. No. 1.01-1.08): 420Kv, 3150 A, 63 Ka, Sf6 Gis Bus Reactor Bay Module As Per Section-Project, Technical Specification , 420 Kv, 3150 A, 63 Ka, Sf6 Gis Line Feeder Bay Module (Without Pir) As Per Section-Project, Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Tie Bay Module (Without Pir) As Per Section-Project, Technical Specification , 420Kv, 3150A, 63Ka Sf6 To Air Bushing Including Support Structure , Controlled Switching Device For 420 Kv, 3-Ph Circuit Breaker , 420Kv, 3000A, 63Ka, Single Phase, Sf6 Gas Insulated Bus Duct (Gib) Outside Gis Hall Alongwith Associated Support Structure, Etc. As Per Technical Specification , 420Kv, 4000 A, 63 Ka, Sf6 Gis Bus Bar Module As Per Section-Project,Technical Specification , 420Kv, 3150 A, 63 Ka, Sf6 Gis Switchable Line Reactor Bay Module As Per Section-Project, Technical Specification , Supply- Gis : 400Kv, Special Tools And Testing & Maintenance Equipments As Per Ts (For Item Sl. No. 2.01-2.05): Scissor Lift , Portable Partial Discharge Measurement Test Kit With All Necessary Accessories, Industrial Grade Laptop And Licensed Software As Per Technical Specification. , Sf6 Gas Analyzer , Sf6 Gas Leakage Detector , Sf6 Gas Processing Unit For 400Kv Gis Station , Spares- Gis : 400Kv, 63Ka For 1S, Mandatory Spares As Per Ts (For Item Sl. No. 3.01-3.51): 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregauge Cum Switch/ Density Monitors And Pressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressure Gauge Cum Switch For Connecting Gas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets, ’ORingsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags (5% Of Total Weight) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , 400Kv Gis-Sf6 Gas (5% Of Total Gas Quantity) , Locking Device To Keep The Dis-Connectors (Isolators) And Earthing/ Fast Earthing Switches In Close Or Open Position In Case Of Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators (Gas Through) Of Each Type (Complete With Metal Ring Etc.) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type (Complete With Metal Ring Etc.) Along With Associated Contacts And Shields , 400Kv Gis- 3150A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors,Push Buttons, Switches,Lamps,Annunciation Windows, Mcb, Fuses,Timers, Terminal Blocks Etc. Of Each Type & Rating-400Kv Gis , 400Kv Gis-One Pole Of 3150A Circuit Breaker Without Pir With Interrupter, Main Circuit, Enclosure And Operating Mechanism Complete In All Respect , Trip Coil Assembly With Resistor For 420Kv Gis Circuit Breaker (As Applicable) , Closing Coil Assembly With Resistor For 420Kv Gis Circuit Breaker (As Applicable) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. (Asapplicable) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drive Motor (For Hydraulic Operated Mechanism, If Applicable) , Hydraulic Filter Of Each Type (For Hydraulic Operated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type (As Applicable) (For Hydraulic Operated Mechanism, If Applicable) , 400Kv Gis Circuit Breaker - N2 Accumulator (For Hydraulic Operated Mechanism, If Applicable) , Valves Of Each Type (For Hydraulic Operated Mechanism, Ifapplicable)-400Kv Gis Circuit Brekaer , Pipe Length (Copper & Steel) Of Each Size & Type (For Hydraulic Operated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type (For Hydraulic Operated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type (For Hydraulic Operated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil (5% Of Total Oil Quantity)(For Hydraulic Operated Mechanism, If Applicable) , Pressure Relief Device Of Each Type (For Hydraulic Operated Mechanism,If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanism Including Charging Mechanism Etc. (For Spring Operated Mechanism, If Applicable) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. (For Hydraulic-Spring Operated Mechanism, If Applicable) , Pressure Switches Of Each Type For420kv Giscircuit Breaker (For Hydraulic-Spring Operated Mechanism, If Applicable) , Pressure Gauge With Coupling Device Of Each Type (For Hydraulic-Springoperated Mechanism, If Applicable)-400Kv Gis Circuit Brekaer , 400Kv Gis- Single Phase Of 3150A Disconnector Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc., Complete In All Respect , 400Kv Gis- Single Phase Maintenance Earthing Switch Including Maincircuit, Enclosure, Driving Mechanism And Support Insulator Etc.,Complete In All Respect , 400Kv Gis - Single Phase Fast Earthing Switch Including Main Circuit,Enclosure, Driving Mechanism And Support Insulator Etc., Complete Inall Respect , Open/Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) One Of Each Type For One Complete Mom Box For 400Kv Gis Disconnector Switch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlocking Coils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) One Of Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earth Switch , Open/Close Contactor Assembly, Timers, Key Interlock, Interlocking Coils, Relays, Push Buttons, Indicating Lamps, Power Contactors,Resistors, Fuses, Mcbs & Drive Control Cards Etc. (As Applicable) One Of Each Type For One Complete Mom Box For 400Kv Gis Fast Earthing Switch , Limit Switches And Aux. Switches For One Complete Mom Box For Disconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Maintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fast Earthing Switch (If Applicable)-400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Single Phase Of Current Transformer (3 Cores, Type-Cta)With Associated Enclosure And Primary Conductor Complete In All Respect , 400Kv Gis- Single Phase Of Current Transformer (2 Cores, Type-Ctb) With Associated Enclosure And Primary Conductor Complete In All Respect , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In All Respect , Supply- Gis : 400Kv, 63Ka For 1S, Reference Unit Price For Addition / Deletion Of Supply Items (Unit Prices Of Individual Equipment Included Here Or In Manadatory Spares Are Required For Any Addition/Deletion Of Equipment And Replacement Of Damaged Items. Vendor To Ensure That The Unit Prices Have A Logical Relationship With Prices Of Assemblies In Main Items. Quoting For Unit Prices Is Mandatory And Shall Be Considered For Evaluation) (For Item Sl. No. 5.01-5.06): Supply- Gis : 400Kv, Single Phase Bus Bar , Supply- Gis : 400Kv, Gis Metallic Enclosure , Supply- Gis : 400Kv, Expansion Bellows/ Joints , Supply- Gis : 400Kv, Tee Bend , Supply- Gis : 400Kv, Angle Bend , Supply- Gis : 400Kv, L-Bend , Services- Gis : 400Kv, 63Ka For 1S, Gas Insulated Switchgear (Gis) As Per Ts (For Item Sl. No. 4.01-4.09): Services- Gis : 400Kv, Supervision Of Erection Of Gis , Services- Gis : 400Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 400Kv, Testing & Commissioning Of Gis , Services- Gis : 400Kv, Testing & Commissioning Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Testing & Commissioning Of Sf6 To Air Bushing , Services- Etc Of Controlled Switching Device For 420 Kv, 3-Ph Circuit Breaker , Services- Gis : 400Kv, Final Successful Hv/ Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- Gis : Insulation Co-Ordination Studies For Gis System , Services- Gis : 400Kv, 63Ka For 1S, Reference Unit Price For Addition / Deletion Of Services Services- Gis : Reference Unit Price For Addition / Deletion Of Services (Unit Prices Of Individual Services Included Here Are Required For Any Addition/Deletion Of Equipment And Replacement Of Damaged Items. Vendor To Ensure That The Unit Prices Have A Logical Relationship With Prices Of Assemblies In Main Items. Quoting For Unit Prices Is Mandatory And Shall Be Considered For Evaluation) (For Item Sl. No. 6.01-6.05): Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item/ Equipment - Services For Supervision Of Erection Of Gis , Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item/ Equipment - Services For Testing & Commissioning Of Gis , Services- Gis : 400Kv, Demobilization And Remobilization Charges For Gis Erection Supervision Team , Services- Gis : 400Kv, Demobilization And Remobilization Charges For Gis Testing & Commissioning Team , Services- Gis : 400Kv, Demobilization & Remobilization Charges Of Hv Test Kit Along With Operator
|