Tender For Provision Of Car Parking Shed At Acad Dept At Ota Gaya; 1 M&L for Surface dressing n exc 15cm deep in soft/loose soil as in berm. 2 M&L for Removing excavated soil to a dist exc.250m & n.exc 1.00 Km 3 Returning, filling in,incl spreading,levelling,watering and well ramming in layers not exc 25CM soft/loose soil 4 Excavation in trenches n exe 1.5 mtr wide and n exe 1.5 mtr deep for foundation etcall as specified and directed 5 M&L Cement concretec D2 (1:4:8) 40 mm graded aggregatein foundations,filling and mass concrete all as specified and directed 6 M & L for reinforced cement concrete (nominal mix) type B-1, (1:2:4) (20mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 7 M & L for reinforced cement concrete (nominal mix) type B-1, (1:2:4) (20mm graded aggregate) in columns,pillars,piers,post and strutscomplete all as specified and directed. 8 M and L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips 9 M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 10 Form work to sides of rough finished flat concrete surfaces of foundations,footing,bases of columns,raft and raft beams,sides of soffits (if any)of foundation and plinth beam;and similar work;vertical or to batter 11 Form works to rough finished surface sides of squire,rectangular or polygonal pillars,posts,struts,piers,columns and stanchions 12 S&F mild steel work as in squire/rectangular/ tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240 with and including one shop coat of zinc chrominium primer paint complete all as specified and as directed. 13 M & L for preparation of new or previously untreated surfaces of steelany description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 14 S and F of framed work such angles or tees with web and flanges cut to shape,drilled and counter-sunk for screw,incl bending and welding angles,as necessery gusset plates not les than 10mm thick,reveting etc not exc 10 kg each brackets confirming toFe-290gde-E-165 15 S&F mild steel screw bolts embedded in concrete for anchoring 16mm dia (machine made) with hexagonal or squire head at one end and screwd the other ,or screwd both end s,each screwd end to be fitted with washers and one hexagonal or squire nut,not less than 60 cm long 16 Supply and fixing Pre-painted galvanised aluminumum zinc coating GI based corrugatedsteel sheet 0.50 mm thick of and colour having tensile strehgth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 17 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ 150) as in covering crumple joint/roof covering/cladding to wall,fixed with self tapping screws as specified 18 M & L for 75 mm thick Plain Cement concrete type C- 2, (1:3:6) (40mm graded stone aggregate) as in sub base. 19 Sand filling under floors for cushioning ofincluding watering and consolidation 20 M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed. 21 M & L for Providing, cement concrete type B1, (1:2:4) (using 20 mm graded stone aggregate) in cills, steps; seismic and other similar bands, plinth courses copings including necessary form work all as specified and as directed 22 M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified 23 M&L brickwork with sub class "B" old size bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified. 24 M & L for 10 mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed. 25 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.
|