Tender For Special Repair Of Otm Building No P-10 And Sewage Line Approx 235M And 22 Nos Of Chamber Under Ge North Binnaguri; 1 Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed. 2 M & L for non skid coloured ceramic floor tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.18 sqm but n exc 0.38 sqm, in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed. 3 M & L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but n. exc 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including cement screed bed/ backing layer of 15mm thick in cement mortar (1:6) complete all as specified and as directed.Note: screed bed shall also deemed to be included in the quoted rate by the contractor). 4 M&L for glazed ceramic coloured tiles 350x250x7/450x350x7mm thick for work on vertical surface such as skirting, dado, set & jointed in cement slurry and pointed in white or coloured cement to match with 10mm thick rendering in CM (1:4) as rough surface on vertical surfaces as backing coat of wall tiles complete all as specified and as directed. 5 Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed. 6 Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed. 7 S&F of Tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. 8 Refixing old 15mm Gl tubing and connections on new or old position (walls, ceiling, floor etc) complete all as specified and as directed.(Note:- The serviceable GI tubing obtained from taking down shall be reused) 9 S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed. 10 Refixing old 20mm Gl tubing and connections on new or old position (walls, ceiling, floor etc) complete all as specified and as directed (Note - The serviceable Gl tubing obtained from taking down shall be reused) 11 Demolition of RCC as in slab beam lintels, shelves chajjas reinforcement cut as required to facilitate demolition complete all as specified and as directed. 12 M&L for RCC 1:1.5:3 Type A1 ( using 20 mm graded stone agg) as in slab supported on walls chajjas complete all as specified and as directed. 13 M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 14 M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges rough finished concrete surface complete all as specified and as directed. 15 M&L for formwork tosoffits of suspended slabs such as roof slabs, floor slabs, landing and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surface of concrete complete all as specified and as directed. 16 M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including sub-ports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface or concrete complete all as specified and as directed. 17 Material and labour 15-18 mm thick Granite ( Jet Black) work ( table rubbed and polished) in steps , jambs, pillars,floors, window cills, cooking platforms and like in cement mortar ( 1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screeding in CM 1:4including full rounding the exposed surfaces complete all as specified.( Note Screed bed shall not be measured and paid separately). 18 M & L for precast cement concrete louvers and jallies set in cement mortar 1:4 Type B0 1:2:4 (12.5mm graded aggregate), 25mm thick (measured solid) including all mouldings but excluding framecomplete all as specified and as directed. 19 Dismantling water tanks and removing to store of any capacity of description whether 500/1000 ltrs, complete all as specified and as directed. 20 S&F 1000 ltrs capacity rotational moulded polyethylene water storage(cylindrical vertical with closed top) triple layer hoisted and fixed in positions complete all as specified and as directed. 21 S&F 20 mm dia PVC ball cock (PVC floatvalves) complete high pressure with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut 22 S&F 20mm bore Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all complete as specified and as directed. 23 Taking down Chowkatswith frame n.exc 1.5 Sqm each without taking off shutters from the frame and refixing the same opening 24 Taking down chowkat with shutter exc 1.5 sqm and n. exc. 4.00sqm each and removing from site. 25 M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 60/50 x 125/105 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 26 M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made etc ,complete all as specified and as directed. 27 Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary fittings shall be paid separately) 28 S&F of Factory made partly glazed ie. upper panel will be wire mesh fitted externallyin the clear space & lower panel will be plain colour PVC sheet 5mm thick PVC door shutter 30mm thick (style ) consisting of frame made out of M.S tubes for top & bottom , rails , MS frame shall be coveredwith heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width struck inside with solvent cement for sides and plain colour PVC sheets for botop rail , lock rail& bottom rail on either side & as gap insert for top rail & bottom rail , paneling of plain colour PVC sheet PVC sheet beading , and jointed together with solvent cement , complete all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary fittings shall be paid separately) 29 S&F for pressed steel frames of thickness 1.25 mm for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm 30 S&F 30mm flush shutter, solid coarse construction, with block board core and plywood face panel, commercial type on both side include for the provision of suitable blocks for mortice locks, latches or other fittings etc complete all as specified and directed 31 S & F35 mm thick 2nd class hard wood glazed and skeleton shutter , open rebated and prepared to receive glass, gauze, etc 9without sash bars), edges of framing plain, chamfered rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats. 32 M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer. 33 M & L for providing plain cementconcrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. 34 S&F of 100 mm long Stain less steel butt hinges as directed. 35 S&F of 150mm long aluminium anodised barrel tower bolt of extruded section and as directed. 36 S&F of aluminium handles cast type anodised 150mm of size. 37 M&L for sliding door bolt of 300mm long plateAluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete. 38 S&F for factory made pressed steel windows of standard size and section , Sheet 1/3 to 3/3 with glazing bars including all fittings like MS hold fast, box hinges, handles, MS tower bolts, stoppers, hinges, MS stay with long screw, MS spring latch, MS gaurd bar/ grill etc complete with glazing bars including one shop coat zinc prime complete all as specified and as directed.Notes:- (i) Rate quoted shall be deemed to be included of all fittings and fixtures. (ii) MS Guard bars and painting shall be measured and paid separately under relevant items of Sch. 39 All as per item No 38 herein above but without glazing bars complete all a specified and as directed. 40 S&F mild steel work such as window guard bars and similar work conforming to Fe – 290 Grade – E 165 complete all as specified and directed. 41 S & F in repair Harrison/curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. 42 Supply and fixing Factory made uPVC white colour fixed glazed window/ventilators made of (small series)frame 47x50mmmullion 47x68mm both having wall thickness of 1.9mm + 0.2mm and single glazing bead of appropriate dimension (area upto 0.75sqm ) comprising of uPVC multichambered frame and mullion (wherever required),extruded profile duly reinforced with 1.60+0.20mm thick galvanised mild steel section made from roll forming process of required length ( shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimensions, EPDM gasket ,GI fasteners 100x8mm size for fixing frame to finished wall plastic packers , plastic caps, and necessary stainless screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, including drilling of after fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality , complete all as specified and directed by Engineer-In-Charge. (Glass or wire mesh shall be paid separately). (Note:- For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e , in depth & width of profile shall be accepted but no extra payment on this account shall be made.) 43 M&L preparation of new surface of steel any description over 10 cm in width or girth not otherwise described two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed. 44 M&L for preparation of old steel and iron surfaces of any description not otherwise described, over 10 Cm width or girth and applying one coat of synthetic enamel paint 1st quality complete all as specified and directed 45 Hacking out old broken glass (any thickness,size,or description) from wooden frames or glazed with putty or fixed with wooden beads complete all as specified and as directed.. 46 S&F3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square n.exc 0.5 Sqm in each pane complete all as specified and as directed. 47 S & F in repair stainless steel wire cloth 0.36 nominal dia wire & average width of aperture 1.40 mm fixed with stainless steel wire staples complete all as specified and directed 48 S&F in repairs 15mm diawall mounted fancy type Bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete. Make- CERA Vine Bib cock, Cat Part No- F1020151 or of Techno commercially equivalent model in other approved make as listed in list of makes. 49 S&F in repairs15 mm diaCP cast copper alloyangle cockscrewed for iron pipe and fixed (Make: CERA Cat no. F1016201 or of Techno commercially equivalent model in other approved make as listed in list of makes .) 50 Supply only15 mm bore fancy type concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, Make:- CERA Cat part No. F 1015361CH or of Techno commercially equivalent model in other approved make as listed in list of makes. 51 S&F in Repairs10 ltr capacity PVC Twin flushing cistern low level white colour with inlet ball valve float and handle including brackets incl PVC connection 450 mm long, PVC flush pipe of reqd length ,and connections to pipe etc complete all as specified and directed. (Make: CERA COMPASS Cat. No. B1020106or of Techno commercially equivalent model in other approved make as listed in list of makes.) 52 S&F in repairs vitreous chinasquatting panOrissa pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with P or S trap front or back inlet etc including connection to trap and flushing pipe and provision of cement concrete bedding complete all as specified and as directed in repairs including demolition of existing one 53 Supply and fixed in repairs white vitreous china wash down water closet pan (pedestal pattern) EWC, with ‘P’ or `S trap, including fixing bolts, Plastic water closet seat and cover, closed pattern with flat bottom, and mild steel chromium plated or aluminised hinging device, including making all necessary connections complete all as specified and as directed.(Make: CERA CELEB Cat. No. S1053121S or of Techno commercially equivalent model in other approved make.) 54 Supply and fixed in repairs 15 mm bore fancy type bib taps long body (two in one) cast copper alloy single handle and wall flange chromium plated screwed down. Make:- CERA Cat part No. F-1015163or of Techno commercially equivalent model in other approved make. 55 Supply and fixed in repair CP health faucet (ABS body)mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook .Make Cera Cat no. F-9090902AB or of Techno commercially equivalent model in other approved make as listed in list of makes 56 S&F only vitreous china wash basin Table top, white oval shape including waste chain and plug and porcelain stopper but including brackets, waste pipe & CP waste coupling, PVC connection 450 mm long complete all as specified and as directed. CERACARMONA Cat part No. S2020162 or of Techno commercially equivalent model in other approved make as listed in list of makes. 57 S&Fin repairs 15 mm bore pillar taps, capstan head, cast Copper alloy,chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.(Make: CERA F1018102 or of Techno commercially equivalent model in other approved make as listed in list of makes.) 58 S&F in repair swivel shower of brass CP with shower arm 125-200 mm size and wall flange for fixing with 15 mm bore GI pipe complete all as specified and as directed.(Make: CERA Cat No. F7020111AB or of Techno commercially equivalent model in other approved make as listed in list of makes.) 59 Supply & fixed in repair Towel Rail 600 long chromium plated , including all necessary fittings, connections etc.Make – Cera Cat Part No F5003103 or of Techno commercially equivalent model in other approved make as listed in list of makes. 60 Supply Soap Holder chromium plated, including making all necessary fittings, connections etc complete all as specified.Make – Jaquar Cat Part No CAN 1135N or of Techno commercially equivalent model in other approved make as listed in list of makes. 61 S&F600mm x 450 mm beveled edge mirror of selected quality glass, mounted on wall and fixed to stainless steel fancy plugs with chromium plated brass screws and cup washers,complete all as specified and directed by Engr-in-charge. 62 S&F in repairsPVC connection pipe 15mm size withP&T nuts of length 450mm 63 S & F in repair Grating doom 125 mm dia with waste hole/without hole of PTMT (Minimum weight 40gms) complete all as specified. 64 Taking down cement plaster on wall / Ceiling of any description incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. 65 Demolition of brick work built in cement mortar of any description,etc complete all as specified and directed. 66 M&L for brick works with fly ash bricksstraight or curved on plain exc 6mmean radius built in cement mortar 1:6 complete as directed. 67 M&L for brick works with fly ash bricksstraight or curved on plan to any radius in half brick thick walls,built in cement mortar 1:6 complete as directed. 68 M&L for rendering 5 mm thick cement plaster on ceiling cement mortar(1:3) finished the surface even and fair without using extra cement complete all as specified and as directed. 69 M&L for rendering 15 mm thick cement plaster onfair face ofsurfaces of brick work or concrete surface in cement mortar(1:6) finished even and fair without using extra cement complete all as specified and as directed. 70 M&L for 15 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers first layer of 10 mm thick and top layer of 5 mm thick plaster with water proofing compoundas per manufacturers instructions finishing the surface even & fairwithout using extra cement complete all as specified and as directed.(NOTE :Water Proofing Compound shall be measured and paid separately under relevant item of this Schedule A) 71 Supply only liquid water proofing compound complete all as specified and as directed. 72 M&L for applying two coat of exterior emulsion paint(weather coat) over a coat of exterior primeron a new plastered surfaces of walls including projection, RCC jalies & post etc including necessary preparation of surfaces complete all as specified and as directed. 73 M&L forpreparation of newly ceiling plastered surfaces and applying three coats of whitewash on wall as specified as directed. 74 M&L preparation of newly plastered surface and applying two coats of oil bound distemper over a coatwall care putty over plastered surfaces including priming the surface complete all as specified and directed 75 M&L preparation of old plastered surface and applying two coats of oil bound distemper over a coatwall care putty over plastered surfaces including priming the surface complete all as specified and directed 76 M&L for preparation of Old decorated surface of ceiling and applying twocoats ofWhite wash complete all asspecified and as directed 77 M&L for preparation of old plastered or unplastered surfaces, of walls including cornices, pilasters and other wall features etc by washing rubbing down and stoppingand applying and finishing the walls withpremium acrylic smooth exterior weather proof paint with silicone additives of required shade (luster paint) applied @1.43 ltr/10 sqm over and including priming coat of exterior primer applied @0.90ltr/10 sqm complete all as specified and as directed. 78 Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) all as specified and as directed. 79 M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in plinth protection finished fair and even without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metres and every change of direction and filling the same with & including bitumen and sand 1:3 by weight of grade Acomplete with and including necessary form work etc complete all as specified and as directed. 80 M&L for75mm thick PCC 1:4:8 type D-2 as in sub base using 40mm graded mechanically crushed stone aggregatecomplete all as specified and directed 81 M&L for 25mm thickpre-polished and chemically treated smooth finish exterior grade coloured chequered tile (300X300)as in pathincluding 15 mm thick Screed bed in CM 1:6 all as complete and as specified anddirected. 82 M&L for providing plain cement concretetype B0 1:2:4 with using 12.5mm graded stone aggregates in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. 83 Taking down or demolition and breaking up drain pipes(SGW,AC,PVC SWR)75/ 100 mm dia complete all as specified and as directed. 84 S&F 75 mm PVC(SWR) pipe socketed in any length with rubber ring joints,laid in trenches or in floorscomplete all as specified and as directed. 85 S&F 110 mm bore PVC (SWR) pipes single sockets in any length with rubber ring joints fixed to wall or laid in floor complete all as specified and as directed. 86 S&F PVC(SWR) 75mm bore bends, diminishing pieces or tapers complete all as specified and as directed. 87 S&F PVC(SWR) 110 mm bore bends, diminishing pieces or tapers complete all as specified and as directed. 88 S&F of PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement outer dia 75 mm cement concrete (1:2:4), type B1 including complete all as specified and as directed. 89 Taking down existing tarfelt including tiles, lime concrete & screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50m and n. exc.100m incl roughening ofold concrete surface of roofby wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. 90 M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying waterproof coatingfinished even and smooth without using extra cement complete all as specified and as directed. 91 M&L for providing and applying single componentacrylic polymer modified, fibre reinforced waterproof coating in 4 coats of application(a) applying primer coat with Primer @ 0.3 kg /sqm (b) over priming coat applying roof guard as specified below or manufacturer instructionswith fibre reinforcement a width of approx 1m @ 0.75kg/sqm on the flat or verticalsurfaces over parapet wall and ensure that there are no bubbles of creases. Overlapping of the fibre is a minimum of 50mm and allow this coat to dry for a period of 2-6 hrs depending on the atmospheric condition. (c) Applying second coat of roof guard @0.75Kg/sqm(d) Applying final coat ofprimer @ 0.08kg/sqm after 2nd coat has dried properly.(Note : Water Proofing treatment shall be carried out by authorized applicator approved by the manufacturer.) 92 Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified 93 M&L for rolled mild steel framed work in tubular trusses such as roof trusses,trussed,purlines, crane gantries, rails and fastenings and heavy bracket framingincluding distance pieces, cleats etcs including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 complete all as specified and directed. 94 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. 95 Demolition & breaking up drain pipes(salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 150mm complete all as specified and as directed. 96 Demolition & breaking up drain pipes(salt glazed ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 200mm complete all as specified and as directed. 97 Excavation in trenches n. exc 1.5M wide and n. exc 1.5m in depth for foundation etc in soft/loose soil. complete all as specified and as directed. 98 M&L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified and as directed. 99 M&L for 200mm dia Reinforced concrete pipes, class NP2 laid and jointed bore of bend 150mm complete with collar all as specified and as directed 100 S&F for Reinforced concrete pipe (SWR) bends any radius fixed to pipes/steel gutters etc bore of bend 200mm complete all as specified and as directed 101 S&F for Reinforced concrete pipe (SWR) bends any radius fixed to pipes/steel gutters etc bore of bend 150mm complete all as specified and as directed 102 S&F for RCC (SWR) branch piece, single (Single Y) equal or unequal radius fixed to pipes/ steel gutters bore of branch pipe 200mm complete all as specified and as directed 103 S&F for RCC (SWR) branch piece, single (Single Y) equal or unequal radius fixed to pipes/ steel gutters etc complete all as specified and as directed 104 M&L, cement concrete 1:4:8 type D-2 bed to 200mm dia bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed 105 M&L, cement concrete 1:4:8 type D-2 bed to 150mm dia bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed 106 M&L hard core of broken stone or boulder for gauge n. exc 63mm, deposited spread and leveled in layer n.exc 15cm thick watered and rammered to a true space complete all as specified and as directed. 107 M&L Cement concrete 1:4:8 type D2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and as directed. 108 M&L for returning, filling in including spreading, leveling watering & well ramming in layers n. exc 25cm complete all as specified and as directed. 109 M&L for removing excavated material soil beyond 50m and upto a total distance of 250m depositing where directed at a level n. exc 1.5m above the starting pointcomplete all as specified and as directed. 110 M&L for PCC 1:2:4 type B1 as in surface channel, bencing and drains in manholes complete all as specified and as directed. 111 Demolition of reinforced cement concrete of any description of in any position such as precast manhole cover or cover slabs of septic tank etc (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. 112 M&L for precast RCC 1:2:4 type B1 (using 20mm graded aggregate) as in landing cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, managers shelves and similar articles with plain facecomplete all as specified and as directed. 113 M&L for cutting into existing manholes for connecting new drains for internal dia of 150mm pipe and making good to pipe and rendering, cutting out existing bendhing for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching as required complete all as specified and as directed. 114 M&L for cutting into existing manholes for connecting new drains for internal dia of 200mm pipe and making good to pipe and rendering, cutting out existing bending for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching as required complete all as specified and as directed. 115 M&L for 50mm thick cement concrete 1:3:6 type C1 (using 20mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throatingcomplete all as specified and as directed. 116 Taking down copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. 117 M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour codingdrawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etcincluding provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modularswitch/ fittingsconcealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits andsinking for boxes and making good to the disturbed surfaceof wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brassthimbles. all as specified and as directed for the following :- (a) One light point controlled by one way switch 5/6 amps. 118 All as per item No 117 above but One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps. 119 All as per item No 117 above but One socket out let 5/6 amps point on the independent board 120 All as per item No 117 above but One socket out let 5/6 amps point on the same board 121 All as per item No 117 above but One bell point controlled by one way switch 5/6 amps. 122 All as per item No 117 above but One light point controlled by two way switch 5/6 amps. 123 All as per item No 117 above but wiring with 2.5 sq mm single coremultistranded copper conductorincluding provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , for one socket out let 15/16 amps point on the independent board complete all as specified and directed 124 S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. 125 S&F of Modular switch, single pole, two way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. 126 S & F Bell Ding Dong, AC Single Pole, 220/240Volts, surface type complete all as specified and directed. 127 S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. 128 S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed. 129 S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed. 130 S&F of Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. 131 S&F of stepped type modular electronic fan regulator 120 watt 2 module suitablefor 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed. 132 S & Flamp holder, insulated body, with back plate suitable for batten/anglefittings complete all as specified and directed. 133 S&FLED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed. 134 S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. 135 S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2 KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. 136 S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser,integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified. 137 S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge. 138 Taking down carefully Ceiling fan from its original position and refixing / hanging afterplaster work including painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, all as specified and as directedcomplete all as specified and directed. 139 Materialand labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) ofsize not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits &making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE: Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one runof PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles 140 S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCBS/lsolators with andincluding taking down old one complete all as specified and directed. 141 S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed. 142 S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KAcomplete all as specified and as directed. Make :L & T ,Cat No: BB40630C,& Eqv to Legrand/ Hager/ABB/C&S. 143 S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unsv one as specified and as directed. 144 S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unsv one as specified and as directed. 145 M & L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc complete all as specified and as directed. 146 Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate of SSR Part- I including testing on completion all as directed and as specified. 147 Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (1”) dia,complete with all accessories all as specified and directed by Engineer-in-charge. 148 Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 25 mm dia bore complete with all accessories all as specified and directed 149 M& L for cutting existing 40mm dia GI pipe alteration or addition of 20 dia bore for insertion of reducer Teecomplete with all accessories all as specified and directed 150 Removing excavated materials n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level all as specified and directed 151 Taking out old unserviceable cable of any size carefully from trenches offer disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note :The Excavation and earth work shall be measured and paid separately under relevant item of Schedule. 152 Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule A).complete all as specified and as directed. 153 Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. 154 Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. 155 M & L for horizontal boring across the existing road without disturbing the road surface for inserting40mm bore GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch A. 156 M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
|