|
Tender For Provision Of Offers Mess Under Ge (N) Udhampur; 2 Construction of block of Offrs Mess complete all as shown on drawings and as specified. 3 Construction of block of Servant Quarter complete all as shown on drawings and as specified. 4 Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified. 5 TotalAmount of Sch "A" Part - II (Internal Water Supply Work) 6 TotalAmount of Sch "A" Part - III (Internal Electric Supply Work) 7 TotalAmount of Sch "A" Part - IV (Plumbing Work) 8 TotalAmount of Sch "A" Part - V(Area Drainage Work) 9 TotalAmount of Sch "A" Part - VI (Sewage Disposal Work) 10 TotalAmount of Sch "A" Part -VII (Road, Path, Culvert and Hard Standing Work) 11 TotalAmount of Sch "A" Part - VIII (External Water Supply Work) 12 TotalAmount of Sch "A" Part - IX (External Electric Supply Work) 13 TotalAmount of Sch "A" Part -X (Compound Wall , Fencing and Gate Work) 14 TotalAmount of Sch "A" Part -XI (Hot Water Supply Work) 15 Sch "A" Part - XII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only. 16 Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. 17 Construction of soakage well (Brick construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. 18 Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 120 litres and nominal cooling capacity of 60 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed. 19 Supply, installation and comminssioning of refrigerator, double door BEE 5 star rated frost free, digital inverter with hermetically sealed compressor of min capacity 256 litres suitable to use on 230 volt, AC supply complete all as specified and directed. 20 Supply, installation and comminssioning of metal top deep freezer BEE 5 star rated hard top having capacity 320 litres, double door, single phase 240 V, 50Hz, complete all as specified and directed. 21 Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. 22 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating inverter technology and EER 3.2, single phase, capacity 1.5 TR, complete all as directed. 23 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating inverter technology and EER 3.2, single phase, capacity 2.0 TR, complete all as specified and directed. 24 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 25 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 26 Supply, installation, testing and commissioning of solar hot water heating system (Flat plate collector) based on indirect transfer of heat for 300 liters as per IS-12922 and IS-12978 with electrical backup of 2KW, including angle iron support (60mmx60mmx6mm) with nut, bolts, washers and painting with two coat of synthetic enamel paint over one coat of red oxide primer for mounting of hot water plant and cold storage tank, complete all as specified and as directed.Note:- Cold water storage tank shall be measured and paid separately. 27 Construction of valve pit of size (90x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. 28 Supply , installation, testing & commissioning of transformer of capacity 100KVA step down outdoor type level - III, copper wounded, 11/0.433KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise shoud not exceed 35 degree centigrade on top of oil when measured on thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 transformerlossess shall be as per latest ammendment No IV as per IS 1180 part - I 2014 and comprising of following accessories complete all as specified and as directed. (Contd.../) 29 a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phaseconnected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips.(Contd.../) 30 h) OneNo thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level guage.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of tranformer oil conforming to relevent ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformerNote : Transformer must be as per Energy efficiency Level-3 of IS: 1180:2014 with amendment No. 4. 31 Construction of PCC platform for transformer of size 3m x 3m and 1m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. 32 Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 33 10W decorative inverted tripod type LEDBollard with IP-65 protection, soft 360 degree light distribution body made of die cast aluminium & in triangular shape including 10 W LED with IP 65 ingress protection, 4 KV surge protection, Luminaire should have high efficiency isolated poted driver minimum height of bollard 800mm & with 180mm OEM should have inhouse NABL approved Lab & submit LM-79 report along with NABL certificate, PCC foundation with necessary nuts & bolts complete all as directed by GE. 34 Post top lantern, LED type, 40 watt including40 watt LED AC, outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact, glare free and better uniformity and corrosion resistant, LED driver shall be constant current type potted driver, luminaire shall have surge protection devices of minimum 10KV inside the driver compartment. Total harmonic distortion shall be <10% with power factor minimum 0.95.The driver shall have an effiviency>85%. It should give consistent performance in the input voltage range of 120V-270V at 50Hz, luminaire shall be embossed or screen printed with manufacturer name/logo, OEM should have in house NABL approved lab and submit LM79 report along with NABL certificate, PCC foundation with necessary nuts and bolts complete with driver and lamp complete all as specified and as directed. 35 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 36 Sintex box of size 155mmX210mmX92mm, hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cablefor phase and neutral fixed on polewith the help of MS nuts bolts and MS clamps; 2 No of size 40mm X 4mm thick, with one No MCB SP 6 Amp capacity mounted on din rail inside box, including making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light, complete all as specified.Make:- Hensel, Sintex or equivalent make approved by GE. 37 LED street light fitting 70 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. 38 Supply, installation, testing and commissioning offactory made "outdoor type" CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5mtr above ground level grouting and bottom portion of enclosure shall be minimum 30cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 39 INCOMING(i) MCCB 4 pole 160 Amp 16 KAKA thermal magnetic adjustable type- 01 No. (Incoming) (ii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(iv) Indicator lamp neon/ LED type RBY -01 Set of three.v) Aluminium bus bar capacity 250 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i) MCCB 3 pole 125 Amp 16 KA thermal magnetic adjustable type -02 No. (Outgoing)(ii) MCCB 3 pole40 Amp 16 KAKA thermal magnetic adjustable type01 No. (Outgoing)(iii) MCB SPN 32 Amps 10 KA - 01 No (Outgoing)(iv) Time switch 250 V single phase of 20 Amp rating - 01 No(v) Complete wiring of the panel board with FRLSH PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron.Note: The rate quoted should include the cost ofexcavation/PCC work as per manufacturer"s recommendation. 40 Bracket made out of GI tubing 40mm dia, light grade 1.5mtr long including fixing withMS clamps - 2 No made out of 50mm wide, 5mm thick, flat iron with M.S nuts bolts 75 mm long 12mm dia, - 4 No with flat washer (3mm thick) - 02 No including painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete, including 1.5sqmm 3.0 core, flexible Copper cable from juction box to connecter of street light fitting complete all as specified and as directed. . 41 Cable route marker with route indication at every 30m length on cast iron disc of 100mm dia and 5mm thick, marked/written for "HT cable 11000 VOLTS" embosed including indication direction fixed/bolted to 40mm x 40mm x 6mmthick MS angle iron support of 0.50 m long embedded upto 200mmdepth in concrete block of size 200mmx200mmx500mmcasted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surface, complete all as specified and as directed. 42 Road crossingby adopting trenchless tunneling work through specilised pipe jacking method by errecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any kindof soil including hard rock,inserting DWC HDPE casing pipe in any length, and necessary conveyance charges of machinery and other required materials in co-ordination with the concered authorites all as specified and as directed. Note: Quoted rate is deemed to be inclusive of all necessary tools/plant/machinery and obtaining necessary permissions to carryout the work. 43 Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- 44 One light/fan/bellpoint controlled by one switch 45 One 3/5 pin socket outlet, 5 Amp on independent board 46 One socket outlet 3 Pin, 5 Amps, on the same board 47 One two way point controlled by one 2 way switch 48 One light point controlled by 2 way switches, 49 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 50 Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia, medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 51 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 52 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run ofsingle core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 53 Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge. 54 MCB, Single pole, 240 volt, 40 Amp, 10KA rating,"C" curve, complete with connection testing and commissioning, complete all specified and directed. 55 Deduction to be made from BOQfor Sch "A" Part -XIII (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule.
|