|
Tender For Special Repair To Building Nos P-95, P-96, P-97, P-100, P-882 & P-885 In The Aor Of Age B/R-Ii Under Ge 864 Ews(Job No: W/Sr (Bldgs)-23/Bb Cantt/2025-26); 1 Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15 cm thick below or above ground level complete all as specified. 2 Dismantling wall and ceiling board of any description including cover fillets complete all as specified. 3 M&L for 6mm thick veneered decorative plywood (05 Nos of ply) grade-01 (with BWR resin) with decorative face veneers on the one face fixed with nails to timber frame works fixed in wall/linings complete all as specified. 4 M&L for 6mm thick veneered decorative plywood (05 Nos of ply) grade-01 (with BWR resin) with decorative face veneers on the one face fixed with nails to timber frame works fixed in ceiling etc complete all as specified. 5 S&F second classhardwood plain fillets square, rectangular in section exc 13 Sqcm & not exc 25 Sqcm complete all as specified and directed 6 S&F Door closer hydraulically regulated cost iron body designation No 1 universal type suitable for door shutters up to 700 mm in width and of weight not more than 35 Kgs complete all as specified and directed. 7 Dismantling of timber fillets rails, posts rafter purlins etc under 40 Sqcm in section in any position in framed work complete all as specified and directed. 8 S&F second classhardwood plain fillets square, rectangular in section exc6 Sqcm and not exc 13 Sqcm complete all as specified and directed 9 Dismantling of timber scantlings 40 sq cm and over in sec, in any position, in unframed/framed work complete all as specified. 10 M&L for second class soft wood as in scantling clean sawn fixed in position complete all as specified. 11 M&L for second class soft wood as in scantling clean sawn fixed in position but except wood complete all as specified and directed. 12 Taking down of shutters of any description exc 2 Sqm eachcomplete all as specified and directed. 13 Taking down chowkhats or frame exc. 1.5 Sqm and n.exc. 4 sqm each with shutter (without taking out shutters from the frame) complete all as specified. 14 Taking down chowkhats or frame n.exc. 1.5sqm each with Shutter (without taking out shutters from the frame) complete all as specified. 15 M&L for second class soft wood plain, solid straight chowkhats and frames, wrought framed rebated on the solid rounded or chamfered, put together with glue penned and joints complete all as specified. 16 S&F factory made 2nd class soft wood glazed and skelton shutters open rebated and prepared to receive glass, gauge etc (with sash bar) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc supplied and fixed to chowkhats, 30mm thick shutter for window and ventilator as specified in SSR Part-I , Section-8, clause 8.24 (b)complete all as specified and directed. 17 S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed 18 S&F boarding in floors and skirting 2nd class soft wood 25 mm thickplaned one side ,with butt joints and fixed with nailscomplete all as specified and directed. 19 S&F 8 to 10mm thick 2nd class soft wood planed one side & edges tongued and grooved or rebated, with nails in flooring and skirting complete all as specified and directed. 20 S&F 2nd class soft wood wall panelling of good quality wood planed one side and edges tonged and grooved or rebated other side and dovetailed joints, chamfered both sides fixed to frame work with secret nailed as in wall /ceiling panelling 15mm including cornice and beading as required and applying two coats of varnish over a filler coat of thin varnish after preparation of the surface, complete all as specified and directed.Note: Frame work shall be measured and paid separately. 21 S&F for 100mm long stainless steel butt hinges medium weight cold rolled all as specified and directed by Engineer-in-Charge. 22 S&F 200mm long aluminium alloy, anodised barrel tower bolt of extruded section complete all as specified. 23 S&F 150 mm long aluminium alloy, anodised barrel tower bolt of extruded section complete all as specified. 24 S&F 300mm long aluminium alloy anodized sliding door (bolt type) and fixing clips of sheets, cast of extruded sections and fixing bolts and sliding bolts of extruded section of cast-aluminium alloy complete all as specified. 25 S&F aluminium handles, cast type, anodized 150mm long complete all as specified. 26 M&L for two coats of synthetic enamel paint including cleaning dusting of new or previously untreated, priming surfaces of wood /ply wood base surfaces for wall, door, window, ventilator and ceiling not otherwise described over 10cm width or girth complete all as specified and directed by Engr-in-Charge. 27 M&L for applying two coats of synthetic enamel paint including preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described andcomplete all as specified and directed. 28 Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work, complete all as specified and directed. 29 M&L for walling of random rubble stone uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. 30 M&Lbrick work with sub class "B" brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6.all as specified and directed 31 M&L brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified. 32 M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and directed. 33 M&L weather boarding of second class soft wood, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm lap in repair to replace old or decayed boarding in patches including cutting out old, piecing, heading joints etc., and removing dismantling boarding to store complete all as specified and directed. 34 M&L applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation ofsurfaces complete all as specified. 35 M&L for preparation of old painted wooden surfaces of any description and otherwise described over 10 CM width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. 36 M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregate) as in coping with necessary formwork complete all as specified. 37 Dismantling floor hearth wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete all as specified and directed. 38 M&L for non - skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed. 39 M&L for vitrified ceramic tiles 10 mm thick light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding 15 mm thick screed bed in CM 1:6 complete all as specified and directed. 40 M&L for vitrified ceramic tiles 10 mm thick light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm on vertical surface such as skirtings, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10mm thick rendering in CM 1:4 complete all as specified and directed. 41 M&Lfor glazed ceramic tiles in vertical surface 350mm x 250mm /450mm x 350mm and 7mm thick colour and design (as approved) set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 10 mm thick cement plaster inCM 1:4 complete all as specified and directed. 42 M&L for 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified. 43 M&L for 75 mm thick plinth protection in/Sub base PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) complete all as specified and directed. 44 M&L for 75mm thickplain cement concrete 1:4:8, type D2 (using40mm graded stone aggregate) as in sub base flooring all as specified and directed 45 M&L for 25mm thick cement concrete 1:2:4, type B-1 as in sub base under floor and finished rough surface complete all as specified. 46 M&L for 25 mm thick screed bed chequered cement concrete tiles 20 cmX20 cmX25 mm thick sat jointed and pointed in neat cement slurry in floor with grey cement and no pigments with 1:4, complete all as specified and directed. 47 Dismantling of CI or reinforced concrete/PVC/ drain pipe internal dia 100/75mm , jointed in cement mortar and taking out of trenches if required complete all as specified and directed by Engr-in-Charge. 48 S&FPVC (SWR) pipe 110mm bore single in any type with rubber ring joint laid in wall/trenches /floor complete all as specified and directed. 49 S&F PVC (SWR) pipe 75 mm bore single in any type with rubber ring joint laid in wall/trenches /floor complete all as specified and directed. 50 S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed. 51 S&F PVC (SWR) bend any radius 75mm borecomplete all as specified and directed. 52 S&F PVC (SWR)gully trap 125/110mm setting and jointing with solvent cement as fixed in repairs complete all as specified and directed. 53 S&F in repair vitreous China wash down water closet pan (pedestal pattern), white with Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device including PVC valveless, symphonic action type, flushing cistern 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle including brackets fixed with 32 mm PTMT flush pipes to pedestal pan all joints all as specified and directed. 54 S&F PVC(SWR) reducers 75/110mm bore complete all as specified and directed. 55 S&F in repair PVC valve less, symphonic action type flushing cistern, 10 ltr capacity low level, white, with inlet, ball valve, float and handleincluding brackets complete all as specified and directed. 56 S&F sheet glass 4 mm thick ordinary quality one way glazing with rubber gasket in square not exc 0.5 sqm each pane, complete all as specified. 57 S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with wooden beading or with nuts and bolts to existing steel windows/wooden windows complete all as specified and directed. 58 S&F sheet glass 3 mm thick ordinary quality one way glazing with rubber gasket in square not exc 0.5 sqm each pane, complete all as specified. 59 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. 60 S&Fin repair 32 mm waste coupling of PTMT(half or full threaded),(Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed. 61 S&F for chromium plated bib taps, cast copper alloy, fancy type with capstan head, crutch or butterfly handle chromium plated,screwed down high pressure, screwed for iron pipe or for brass ferrule 15/20 mm dia bore, fixed as in repair, complete all as specified and directed. 62 S&F in repair pillar tap 15mm bore cast copper alloy, with cap stain head chromium plated screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 63 S&F angular stop valves , cast copper alloy, screwed down high pressure, fancy type with crunch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions, or for 15mm dia bore, fixed as in repairs, complete all as specified and directed. 64 S&F towel rail 600 mm long (between flanges), 20mm dia, ‘D’ type, chromium plated brass, fixed to walls with screws and plastic cleats, fixed as in repairs, complete all as specified and directed. 65 S&F 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 66 S&F PVC connections of PTMT, non corrosive, with nuts & washers on both ends, 450mm long,suitable for 15mm dia bore pipe, fixed as in repairs, complete all as specified and directed. 67 S&F grating square (SLIT) 150mm size, of PTMT (Openable), fixed as in repairs, complete all as specified and directed. 68 Taking up or down steel tubing and connections, size15 mm dia bore,including cleaning for re-fixingor removal to stores, complete all as specified and directed. 69 Taking up or down steel tubing and connections, size20mm dia bore,including cleaning for re-fixingor removal to stores, complete all as specified and directed. 70 M&L galvanised steel water tubing, "medium grade", with all fittings and fixed complete to wall and ceiling or laid under floor, 15 mm dia bore pipes, including cutting existing steel tubing & screwing, if required for alterations and additions, complete all as specified and directed. 71 M&L galvanised steel water tubing, "medium grade", with all fittings and fixed complete to wall and ceiling or laid under floor, 20 mm dia bore pipes, including cutting existing steel tubing & screwing, if required for alterations and additions, complete all as specified and directed. 72 S&F in repairs vitreous china wash basin, white, flat back, size 550mmx400mm excluding taps, waste chain 7 plug and porcelain stopper but including brackets complete all as specified and directed. 73 S&F in repairs vitreous china bowl urinal flat back,of size 465mmx355mmx265mm white (minimum), with grating and union for discharge pipeincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and includingdischarge pipe of PVC 32mm dia complete all as specified and directed. 74 Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, removing material from site for taking credit etc and making good disturbed surfaces of wall, floors to match with existing surfaces complete all as specified and directed. 75 Taking downMCB DB"s complete with MCB"s/Isolator etc removing materials from siteand making good disturbed surface of walls, floors etc. complete all as specified and directed. 76 Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead in and including cable 1100 Volts grade including casing and capping/conduit (ISI marked)including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxes andsheet of suitable sizes for mounting of switches, sockets, fan regulators, light fittings etc. covered with suitable plastic laminated sheet or PVC gang box 2 to 8 way as per site requirement including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified. 77 All as per ser item No 76 here-in-before but socket outlet 3 pin 5 Amps on same board. 78 All as per ser item No 76 here-in-before but socket outlet 3 pin 5 Amps on independent board. 79 All as per ser item No 76 here-in-before but socket outlet 6 pin 15 Amps on independent board. 80 S&Fswitch piano flush button single pole, one way 5 Amps complete all as specified and directed. 81 S&F of socketoutlet 2 in 1,3 pin, 6A complete all as specified and directed. 82 S&F switchsocket combination 2 in 1,5A, flush type complete all as specified and directed. 83 S&F switchsocket combination 5 pin 16A, flush type complete all as specified and directed. 84 S&F ceiling rose with earth terminal 2/3 connection,PVC/ polycarbonate, isolated body complete all as specified and directed. 85 S&F LED, 20 Watts, 4 ft, fittings complete with all accessories for mounting light fittings complete with earth terminal connection/ PVC/ polycarbonate, isolated body complete all as specified and directed. 86 M&L lamp holder, PVC/Polycarbonate type with cord grip cap suitable for batten fittings complete all as specified and directed. 87 S&F LED Bulb 9 Watt all as specified and directed by Engr-in-Charge. 88 S&F 09W/10W Bulk head luminaires including LED light driver holder connectingup with three core flexible copper conductor cable of suitable size complete all as specified and directed. 89 S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed by Engr-in-Charge. 90 S&F of distribution board single pole & neutral with 200 Amps rated bus bar,for double door IP-42 DB"s ,made outof sheet steel enclosure, recessed type, factory made powder coated12 way 240 Volts suitable for housing MCB"s and isolator"s complete in all fixing material/accessories etc complete all as specified and directed. 91 S&F of distribution board single pole & neutral with 200 Amps rated bus bar,for double door IP-42 DB"s ,made outof sheet steel enclosure, recessed type, factory made powder coated8 way 240 Volts suitable for housing MCB"s and isolator"s complete in all fixing material/accessories etc complete all as specified and directed. 92 S&F MCB"s single pole 240 volts 6 to 32 Amps 10 KA "C"curve series, all as specified anddirected by Engr -in-Charge. 93 S&FRCBO, single pole and neutral (SPN) 30mA, 240V, 32 Amps all as specified and directed. 94 Supply and Laying ,jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 Volts grade ,cross section area 25 Sqmm 3.5 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. 95 S&F 1100 Volts grade heavy duty cable PVC insulated multistranded aluminium conductor served with PVC tape and overall PVC sheathed in services connections suspended by insulating hanger not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 16 Sqmm 2 core including service bracket complete all as specified and directed. 96 S&F 1100 Volts grade heavy duty cable PVC insulated multistranded aluminium conductor served with PVC tape and overall PVC sheathed in services connections suspended by insulating hanger not more than 1 mtr apart including 4mm dia GI suspension wire one twin core cable flat or circular of size 10 Sqmm 2 core including service bracket complete all as spd and as directed. 97 M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge lead of the plate not less than 1.5 mtr below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point or indicated including testing on completion complete all as specified.
|