Tender For Provn Of Certain Sanction Works In The Area Of Age B/R-I And Age E/M Under Ge (Central) Delhi Cantt-10; 1 Excavating in post holessoft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 2 M&L for Cement concrete type D2 1:4:8 (40mm graded aggregate) as in foundations, filling and mass concrete 3 M&L for Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) includingdistance pieces, cleats etc.Fe 410-W (GdeE- 250) quality A all as specified and directed. 4 S&F Pre-painted galvalume aluminum Zinc coating GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 5 M&L for Straight or Circular raking cutting Fair cutting n exc 10 cm width or girth on exposed surfaces of brickwork such as in splays, chamfers, etc.including rubbed finish and good well surface all as specified and directed. 6 M&L for Preparation of new or previously untreated steelsurfaces of any description, over 10 cm width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified. 7 M&L for 100mm thick PCC (1:4:8) Ty D2 as in sub base over rammed earth. 8 M&L for cement concrete 1:3:6 type C1(using20mm graded stone aggregate) as in blocks for hold fast, coping,benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces complete allas specified. 9 M&L 25 mm thickPCC 1:2:4, type B-0 using 12.5mm graded crushed aggregates as in floor surfaceall as specified and directed. 10 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, all as specified. 11 M&L for joint less Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including provn of 15mmthick screed bed or bedding layer in CM 1:6 etc complete all as specified . 12 S&F mild steel as in hand rail, balusters, noising to steps, post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, drilling, bolting or riveting etc, conforming to Fe-290 , Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. 13 Supply only 3.15 mm dia galvanised steel chain link fencing, 100X100 mm mesh, made up into mattrsses or cages, lapped, wired a all as specified. 14 Fixing only chain link fencing including line wires any mesh, size and type to any to any type of standard, rail, straining bolts, etc. including provn of winding wire all as specified. 15 M&L mild steel round bars 10 mm dia conforming to FE-410-W (Gde E-250) quality A or Fe-290 (Gde E-165) for use in chain link fencing as wind tie all as specified. 16 Mild steel screw bolts(machine made) with hexagonal or square heads at one end screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 30 cm and dia of neack exc 12 mm but not exc 20 mm complete all as specified and as directed by Engineer-in-Charge. 17 Excavation in trenches n.exc 1.5 m wide for foundations, pipe line etc, and n.exc 1.5 m deep and getting out in hard/dense soil complete all as specified & directed by Engineer-in-charge. 18 M & L 75 mm thick sand filling under floors or in foundations including watering and consolidation. 19 M & L Machine pressed precast concrete PU coated colourinterlocking paver block any shape and size, with grey cement and pigment confirming to IS 5658-2006 of 80 mm thicknessM-40 Grade complete all as specified 20 Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etcup to 10m height complete all as specified and directed. 21 M&L for rendering 15mm thick in CM 1:4 on fair faces or other than fair faces of brick work or concrete surfaces firnished even and smooth without using extra cement up to hieght of four storey bldg ,including scaffolding complete all as specified and directed by Engineer-in-charge.. 22 M&L 5mm thick rendering on concrete surfacesin cement mortar 1:3 , as in ceiling, finsihed the surfaces even and smoothwithout using extra cement. 23 Material and labour for preparation of old/new plastered surfaces as of walls and applying Twocoats of weather proofing exterior acrylic emulsion paint of DULUXWeather shield Max or APEX ULTIMA from Asian paintover one coat of primer from the same manufacturerwhite lime wash complete all as specified and directed. 24 M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 25 Demolition Bricks (laid flat or on edge) or brick tiles in floors, roof, channels, kerbs, aprons, etc. (each layer all as specified and directed. 26 Demolition Mud in roofs, any thickness, including plastering and lapping (whether full thicknessremoved or only a part thereof) all as specified and directed. 27 Removing soil excavated material exc. 1.5Km but n exc 5km and depositing where directed at above the starting pointall as specified and directed. 28 M&L for cement concrete 1:2:4 type B1 (using 12.5mm graded stone aggregate) on roof paddingsurface finished even and smooth without using extra cement complete all as spd & directed. 29 M&L for rendering 10-15mm thick in CM 1:4 on fair faces of r concrete surfaceswith using WPC compound @2%of cement weight finished even and smooth without using extra cementcomplete. 30 M&l for Cleaning the entire area first by broom, chipping unwanted area using chisel and hammer, cleaning/ smoothening by wire brush, washing the entire surface using waterjet and finally by broom and airjet and Applying one layer of cement and Nushar make CCP mix in the ratio Cement:CCP:Water::1:1:0.2 and mixing it thoroughly using electric mixer coating to be done atleast 1’ longitudinally to secure edges and Filling all visible cracks using Nushar crack pack master/ Nushar make Cladofix. Laying 66 gsm non woven fiber along with 2nd and 3rd coat of CCP mix and cement mixture as in step 2 . Filling overlapping joints using Nushar make Master adhesive. Apply 1st coat of Nushar make Polymembrane coat using brush across the area. After curing of above layer apply second coat of Polymembrane coat. Apply 1st coat of Nushar make Nano top coat. Ponding test to be done by filling atleast ½” water in the entire area. Removing the water after the test is successfully completed. Apply 2nd layer of Nushar make Nano top coat to finish the work all as spd and directed by Engr -in-charge. Make: Asian Paints or equivalent in Sikka,Birla or equivalent in Berger Fosroc and STP Ltd. 31 Returning filling in soil including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified & directed by Engineer-in-charge. 32 S&F Mild steel rolled section or hollow pipes( square or round pipe)as in main and cross beam, hip and jack rafter, purlins or vertical postwhere connected to common rafter and running rails fixed with cleat or other connecting plates etc. complete all as specifed and directed. 33 M & L for brick work with Cement Mortar1:6 using sub class B bricks,old size , straightor curved on plan exceeding 6 m mean radius all as specified and directed. 34 S & F Expanded metal n exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members all as specified and directed. 35 M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates, 75mm thick in foundation filling and mass concreteall as specified and directed by Engineer-in-Charge. 36 M & L for 75 mm thick cement concrete 1:3:6type C2(using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified. 37 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 38 M&L chequered endura tiles 30cmx 30cmx 10mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 15mm thick screed in cement mortar 1:6 39 M & L for Point wiring complete with 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn throughrigid PVC conduit, including provision of 2.5 sqmm PVC insulated copper cable FRLS as earth continuty conductor and including branded modular metal flush MS terminal boxes, concealed in walls with suitable modular inner and outer plate,top sheet cover for housing switches,socket outlet and fan regulators etc,including making necessary electrical connections all as specified and as directed. 40 M&L switch Modular type 6 Amps 1 Way,1 module, 230V AC including making necessary electrical connections complete all as specified and directed by Engineer in charge. 41 S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge . 42 Supply and fixing ceiling fans complete with remote, blade, down rods, with accessories, rated speed not less than 330 RPM, 230 V,1200 mm sweep, air delivery not less than 220 CMM,BEE five star rated voltage range 140-280 volts with brushess direct current motor (BLDC) including making necessary electrical connection with and including three core copper multistanded cable of size 1.5 sqmm all as specified and directed by Engr-in-Charge. 43 M&L for single pole and neutral enclosure with two pin and earth plug and socket with single pole MCB 20 amps C curve including making necessary electrical connections complete all as specified and directed. 44 Supply and fix electric water heater vertical storage type of capacity 25 ltrs white coloured havinganti rust coating metal body with SS tank and heating element 2 KW, 5 star rated complete with all accessories such as safety valve, adjustable thermostat,auto cut off system, NRV, two Nos SS braided pipe of 12 mm (internal) heavy duty suitable for hot/cold water of suitable length as per OEM with brass nuts and rubber washers etc. and fastners (04 Nos) for mountting of geyser at suitable height and making necessary water connections from existing pipe line including all connected items required at site complete all as specified and directed. 45 M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including in and including concealed / surface PVC conduits as suitable of site Medium gradeofISI Marked not less than 20 mm dia and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified. 46 All as per item No 45 above but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. 47 M&L switch Modular type 6 Amps one way ISI marked 230V AC complete all as specified. 48 M&L Modular socket outlet 5 pin 6 Amp socket 2 moduleISI marked complete all as specified. 49 Supply and fixMCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with tinned copper bus bar, neutral link earth link complet. 50 M&L MCB SPN 40-63Amp curve all as directed. 51 M&L MCB SP 6 to 32 Amp curve all as directed. 52 Fixing only desert cooler PVCbody , single phase, 230 volts, 50 Hz , 200 liters capacity with powerfull exhaust fan, 3 side honeycom cooling pads, low energy consumptionof 20 watts, cools upto 48 sqm, easy fill water system etcall as specified & directedby Engineer -in-Charge. 53 Fixing only fly catcher electronic trap type of size 69x2x.5 cm, effictive area 50 sqm, high quality UV to attact insert un through electric metal grids and the bulb, AC 220-240 volts, 50 Hz, ISI Marked etc all as specified & directedby Engineer -in-Charge. 54 Fixing only Monoblock centrifugal pump set of 5 HP capacity, power rating 3.7 KW, 3000 PM, flow rate 860 to 1250 LPH, suction x Del 65x50 mm, head range : 15 -30 Mtrs with, foot valve, single phase, 250 volts with elect panel with one DOL stater of 5 HP capacity, volt meter & Ammeter grouting/fitted on wall with fastners, coveing with rain shade, pump fixing on platformwith nuts, bolts & washers including testing all as specified& directedby Engineer -in-Charge. 55 Supply & laying GI pipe medium gradeofsize 65 mm dia includingallaccessoriesall as specified & directed by Engr-in-Charge. 56 Supply & laying GI pipe medium gradeofsize 50 mm dia includingallaccessoriesall as specified & directed by Engr-in-Charge. 57 Supply & laying GI pipe medium gradeofsize 15 mm dia includingallaccessoriesall as specified & directed by Engr-in-Charge. 58 Supply & fixing PPR gate valve (brass insert) 65 mm dia allas specified & directed by Engr-in-Charge 59 Supply & fixing PPR gate valve (brass insert) 50 mm dia allas specified & directed by Engr-in-Charge. 60 Supply & fixing PPR valve, stop screwbrass15 mm dia allas specified & directed by Engr-in-Charge. 61 Supply & fixing Foot valve,confiming to IS -4038, 50 mm dia allas specified & directed by Engr-in-Charge. 62 Supply & fixing Stainer, Y type confiming to IS :50 mm dia allas specified & directed by Engr-in-Charge. 63 M & L fo PCC platfarm for fixinf of pump with fastners/nuts & bolts embeded on PCC 1:2::4 type B1, using 20 mm aggegate of size 600 mm x 600 mm x 300 mm all as specified & directed by Enginee-in-Charge. 64 Supply,laying in repairs of PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area10 sqmm 4.0 core laying in trenches, fixed along wall, through GI pipe under floor complete. 65 Material & Labour of DWC ( double wall corrogated )pipe of size 50 x63 mm dia ( innner & outer dia ) laying of XLPE cable all as as specified & directed. 66 M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI streep 25 x 4 mm dia by means of bolts, nuts,check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed. 67 Schedule of Credit
|