|
Repair And Maintenance Services Of Machinery - Eiffel Stage Technical Maintenance_2026. The Customer Orders, And The Contractor Undertakes The Periodic Maintenance And Minor Repair Tasks Of The Stage Technical Equipment Installed On The Site Of The Eiffel Műhelyház (1101 Budapest, Kőbányai Út 30.) Based On The Instructions Prescribed By The Manufacturer Of The Equipment And The Safety Regulations For Theater Arts, In Order To Ensure Continuous Operational Readiness, 12 Times During The Scope Of The Contract. A Minor Repair Task Is Understood As A Repair Task That Arises During Maintenance, Which The Contractors On-Site Maintenance Colleagues, In Addition To Performing The Maintenance Tasks, Can Perform And Complete With Complete Safety During The Available Maintenance Time, And The Necessary Resources (Such As Materials, Tools) For The Repair Are Available. General Tasks: - Investigation Of Errors That Occurred During Operation, According To The Operators Notes, And Finding Their Causes - Motion Tests, Uncovering The Causes Of Possible Abnormal Operation (E.G. Noisier Operation, Jamming, Jamming) - Motion Tests And Simultaneous Visual Inspection General Mechanical Maintenance: - Inspection Of Wires, Weight Rods, Sliding Pads, Periodic Lubrication Tightening Of Fixing Screws As Necessary - Periodic Cleaning Of Drive Chains, Lubrication - Checking The Operation Of The Hydraulic System With A Motion Test, Testing The Condition Of The Batteries, Checking The Filter Units And Hydraulic Oil - Checking The Pneumatic Operation, Compressor Review And Maintenance - Mechanical Cleaning Of The Docking Units, Function Test - Checking The Condition And Connections Of The Ropes, Adjusting The Rope Forces, Possible Untwisting Of The Ropes - Checking The Gears, Checking The Oil Levels - Checking The Functionality Of The Brake Systems, Adjusting Them As Necessary General Electrical Maintenance: A. Electrical Switchboards: - Check Of Screw Connections - Check Of Sliding Lug Connectors, Press New Lugs If Necessary - Check Of The Operation Of Thermostatically Controlled Fans - Check Of The Cleanliness Of Filter Inserts, Dust Removal, Replacement If Necessary - Cleaning Of Connector Contacts - Spray Treatment - Check Of The Condition Of Batteries B. Electrical Control Boxes, Push-Button Panels: - Dust Removal - Check Of Screw Connections, Check And Replacement Of Sliding Goods - Replacement Of Burned-Out Indicator Bulbs - Function Test C. Drive Units: - Inspection Of Cable Fixings, Cable Glands - Inspection Of The Condition Of Limit Switches By Visual Inspection And Function Tests - Inspection Of Connections Of Junction Boxes, Visual Inspection Of Transmitters - Function Test, Inspection Of Rail Current Conductors D. Uninterruptible Power Supplies, Batteries: - Check The State Of Charge - In The Case Of Safety Curtains, Check The State Of Charge Again After The Movement Test Check Of Safety Systems: - Check Of Pinching And Rope Loosening Monitoring - Check Of The Operation Of Safety Doors - Check Of The Operation Of Safety Curtains Repair, Installation T
|