Tender For Provision Of Fire Hydrant At Sre System At Af Station Tezpur; 1 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep in soft / loose soil and getting out complete all as specified and as directed. 2 Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in soft/loose soil complete all as specified . 3 Returning, filling in soil, including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. 4 Removing excavated material n.exc. 50m and depositing where directed to a level n.exc. 1.50m above starting point complete all as specified and as directed. 5 M&L Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed/broken stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed. 6 M&L Brick work with old size sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed. 7 Fixing Only TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping looking for columns, beam, slab etc. hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and as directed.(Note:TMT bars will be issued under Sch B free for fixing for qty as specified, if found serviceable, contractor shall carry out testing as directed by Engineer in charge quoted rates deemed to include the same) 8 S&F TMTsteel bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length, bent to shape required including cranking, bending spirally for hooping looking for columns, hooking ends and binding with MS wire (annealed not less than 0.9 mm dia) complete all as specified and as directed. 9 Fixing onlyTMTsteel bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length, bent to shape required including cranking, bending spirally for hooping looking for columns, hooking ends and binding with MS wire (annealed not less than 0.9 mm dia) complete all as specified and as directed.(Note:TMT bars will be issued under Sch B free for fixing for qty as specified, if found serviceable, contractor shall carry out testing as directed by Engineer in charge quoted rates deemed to include the same) 10 M&L formwork to flat fair finished surfaces of concrete of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter all as specified and directed by Engr-in-Charge. 11 M&L formwork to sides of pillars, post, struts, piers, columns and stanchions complete in flat fair finished surfaces of concrete. 12 M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs etc complete in flat fair finished surfaces of concrete. 13 M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work; not exceeding 200 mm thick (horizontal or sloping) for flat fair finished surfaces of concrete. 14 M&L Reinforced cement concrete design mix M-25 ( using 20 mm graded aggregate) as Foundation, including rafts, footing, foundation beams, plinth beams; bases for column, etc; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engr-in-Charge. 15 Material and labour for 50 mm thick plain cement concrete (1:3:6) Type C2 using 20 mm graded aggregates as in plinth protection/paving including finishing surface even and smooth without using extra cement complete all as specified and directed 16 M&L Reinforced cement concrete design mix M-25 ( using 20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed by Engr-in-Charge. 17 M&L Reinforced cement concrete design mix M-25 ( using 20 mm graded aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed by Engr-in-Charge. 18 M&L Reinforced cement concrete design mix M-25 ( using 20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and as directed by Engr-in-Charge. 19 M&L broken stone hardcore of gauge exc. 63 mm but n.exc. 100 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. 20 Material and labour for brick work with old size sub class "B" bricks, straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick walls complete all as specified and as directed. 21 Material and labour for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cementcomplete all as specified and directed. 22 Material and labour for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick work and finishing the surface even and smooth without using extra cementcomplete all as specified and directed. 23 M&L rendering 5 mm thick in CM 1:3 on fair faces of concrete surfaces as column finished even and smooth ( without using extra cement) complete all as specified and as directed. 24 Material & Labour for rendering 5 mm thick in cement mortar 1:3 as in ceiling and finishing even and smooth without using extra cement all as specified and as directed. 25 Material and labour for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. 26 M&L 100 mm thick cement concrete type B-2, 1:2:4 ( 40 mm graded aggregate) as in floors finished even and rough without using extra cement complete all as specified and as directed. 27 M&L 100 mm thick cement concrete type C-2, 1:3:6 ( 40 mm graded aggregate) as in sub-base and finished even & rough complete all as specified and as directed. 28 M & L rendering 20mm thick in two layers (12mm + 8mm) externally on fair faces of brickwork or concrete surfaces in cement mortar 1:4 and finished the surfaces even and smooth without using extra cement mixed with water proofing compound @ 200 ml per 50 kg of cement on top layer of 8 mm thick complete all as specified and directed (WPC will be measured and paid separately) 29 M&L for preparation of newly plastered wall or concrete surfaces and applying two coats of cement base paint over a coat of cement primer complete all as specified and as directed. 30 M&L rendering 10 mm thick in CM 1:3 on fair faces of concrete surfaces in roof finished even and smooth ( without using extra cement)mixed with water proofing compound @ 200 ml per 50 kg of cement on top layer of 8 mm thick complete all as specified and directed (WPC will be measured and paid separately) complete all as specified and as directed. 31 Material and labour for preparing newly plastered surfaces of wall/column and applying three coats of white wash complete all as specified and directed. 32 Supply only liquid water proofing compound 33 S&F 1.25 mm thick laths steel rolling shutterswith ball bearing, as specified including guide channel, 2 Nos SS Spring, shaft pipe, top cover, hood cover, anchoring rod, hasp and staple and one shop coat of primer and safety lever locks mild steel with 4 levers for rolling shutters ; erected in position as indicated, complete 34 Material and labour for preparation of new steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed. 35 M&L providing, cement concrete 1:2:4 ( 12.50 mm graded aggregate) type B0 in lintels upto 1.5m clear span, calls, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. 36 M&L 100 mm thick cement concrete type B-2, 1:2:4 ( 40 mm graded aggregate) as in apron and spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green over finished cement concrete surface even and smooth without using extra cement complete all as specified and as directed. 37 Supply and fix in repairs10 litres capacity PVC valve less symphonic action type, flushing cistern, low level with inlet ball valve and bracket etc, complete all as specified and directed including taking out old one complete all as specified and directed. 38 Supply and fix in repairs, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed. 39 Supply and fix 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule completeall as specified and directed. 40 Supply and fix 15 mm bore angle valves, cast copper alloy, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. 41 Supply and fixFactory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed. 42 Supply and fix solid PVC door frames of size 50mm X 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube complete all as specified and directed 43 S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)and fixing with "S" trap with vent horn complete all as specified. 44 S&F in repair plastic water closet seat cover for pedestal pan, white colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified. 45 Supply and fix 35 mm thick, 2nd class hardwood plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, complete all as specified and directed. 46 Supply and fix 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete as specified and directed in SSR Part I Section 8 clause 8.24 (b) complete all as specified and directed. 47 Supply and fix Sheet glass ordinary quality & fixed with wooden beads in square n-exc. 0.5 sqm in each pane 3 mm thick complete all as specified and directed. 48 Material and labour for 2nd class hard wood plain, solid, straight chowkhats & frames, wrought, panelled, rebated on the solid, rounded or chamfered put together with glue,pinned at joints complete all as specified and directed. 49 Supply and fix MS holdfast made up of FI 25 X 3mm conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed. 50 Material and labour for PCC 1:3:6, C-1 (using 20 mm graded stone aggregate) as in bed blocks for inserting holdfast, etc including necessary form work complete all as specified and directed. 51 Supply and fix 100mm size mild steel butt hinges medium weight cold rolled complete all as specified and directed. 52 Supply and fix 75mm size mild steel butt hinges medium weight cold rolled complete all as specified and directed. 53 Supply and fix 150 mm long Aluminium anodised barrel tower bolts of extruded section all as specified and directed. 54 Supply and fix 100 mm long Aluminium anodised barrel tower bolts of extruded section all as specified and directed. 55 Supply and fix 150 mm size Aluminium handles, extruded aluminium anodised fabricated type all as specified and directed. 56 Supply and fix 100 mm size Aluminium handles, cast type, anodised all as specified and directed. 57 Material and labour for preparing new wood & wood based surfaces of any descriptions exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 58 Supply and fix aluminium anodized sliding door bolt 250 mm length with hasp, with staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. 59 Supply and fix steel tubes, galvanised 15 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete as specified and directed . 60 M&L for excavation over areas n.exc. 1.5 m deep and getting out for any type of soil all as specified. 61 M&L for excavation over areas exc 1.5m but n.exc. 3m deep and getting out for any type of soil all as specified. 62 M&L PCC 1:2:4 type B-2, using 40mm graded stoneaggregates as in base and finished even & rough complete all as specified and as directed. 63 M&L RCC design mix M-30 (using 20 mm graded stone aggregates) as in base complete all as specified and as directed by Engg-in-Charge 64 M&L RCC design mix M-30 (using 20 mm graded stone aggregates) as in walls complete all as specified and as directed by Engg-in-Charge 65 M&L RCC design mix M-30 (using 20 mm graded stone aggregates) for slab of sump complete all as specified and as directed by Engg-in-Charge 66 S&F TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping looking for columns, beam, slab etc. hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and as directed. 67 M&L formwork to faces of walls and similar work vertical or to batter for fair finished surfaces of concrete complete all as specified and as directed by Engg-in-Charge. 68 M&L formwork to soffit of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for flat and fair finished surfaces of concrete. 69 M8L rendering 10 mm thick in CM 1:3 on fair faces of concrete surfaces as column/wall/floor finished even and smooth (without using extra cement) complete all as specified and directed. 70 Removing excavated material upto a total distance of 250 m and depositing where directed to a level n.exc 1.50 m above the starting point complete all as specified and directed. 71 S&F aluminium ladder fabricated with anodised aluminium section and fixing with SS bolts complete all as specified and directed at site 72 SCHEDULE A PART-III (EXT ELECT) Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor1100 volts grade cross sectional area 120 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately) 73 Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor1100 volts grade of cross sectional area 50 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately) 74 Supply installation, commissioning and testing, including providing all necessary electrical connection, LT feeder panel boad (CPRI Approved), outdoor type, double door, compartmentlaised type, factory made out of3.15 mm thick MS sheet of size 600mm (height) x 500 mm (width) x 300 mm (depth) having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete and comprising of the following accessories including necessary excavation work for taking out cable loop and refilling the trenches all as directed by the Engr-in-Charge:-(a) TP&N solid Aluminium Bus Bars, rated 200 amps supported at required intervals sleeved with heat shrinkable PVC sleevings.The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No. (b)Moulded case circuit breakers (MCCB), with current rating 100 Amps and 25 KA breaking capacity Icu at 415 Volts, 4 pole, AC, 50 Hz, with adjustable Over Load setting : 0.8 -1.0 x In and adjustable short circuit setting: 6-10 x ln - 01 No 75 Excavation in trenches in soft/loosesoil etc n. exc 1.5 m wide and n.exc 1.5m in depth for foundation etc or for laying of pipe, cable etc and getting out complete all as specified and directed by Engineer-in-charge. 76 Material and Labour for dry sand cushioning with coarse sand in trenches for protection of underground electric cable 8cm deep before laying the cable and 15cm thick after laying & stretching of cable complete all as specified and as directed.(Note:- Only punned thickness of 18cm shall be measured and paid) 77 Material and labour for boring holes under road, pavement, hard standing by manual tools for inserting and including GI pipe of 100mm dia complete all as specified and directed. 78 Supply and laying old size sub class "B" bricks well burnt, best quality locally available laid flat with width equal to length of the brickin trenches over sand cushioning for UG cable protection complete all asspecified and directed. 79 Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing factory built sheet steel enclosed non-drawout modular firefightingpanel, fabricated out ofsuitable sized square tubular section andcoveredwith 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, dulypainted to all internal and external exposed steel surfaces with powder coating paint, complete with Aluminium bus bars, inter-connectionwith solid copper conductor wires / aluminium strips, neutral links, earthbusetc. necessary metering protections & indications and mounted with the following as per specification attached as required.BUS BAR CHAMBERTP&N Anodised Copper bus bars, rated 400 amps supported at required intervals sleeved with heat shrinkable PVC sleevings.The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No. INCOMING (i)2 No 160 A TPNMCCB (50 KA) with mechanical/electrical interlocking (ii) 1 Set of RYB indicating lamps with individual RCBO (iii) 1 No Digital AC Ammeter with 3 1/2 digit display and with built in selector switch, Type 3 PH, Range 5 Amps Direct and with CT 200/5 A, size 96 mm X 96 mm, Accuracy Class 1.0. (iv) 1 Nos Digital AC Voltmeter with 3 1/2 digit display and with built in selector switch, Type 3 PH, Range 30-600 Volts direct, size 96 mm X 96 mm, Accuracy Class 1.0OUTGOINGFEEDER FOR MAIN PUMPS(i) 02 Nos125 A TP MCCB , DOL Starter with01 No 0-125 Amps. Ammeter with selector switch and suitable rated current transformers and indicating lamps with ON / OFF push buttons.(ii) 01 No Auto manual selector switchFEEDER FOR JOCKEY PUMPS - 01 No(i) 01 No25ATP MCCB (ii) DOL starter with1 No 0-25 Amps. Ammeter with selector switch and suitable rated current transformers. Starter with over load relay, single phase preventor and indicating lamps with ON / OFF push buttons. (iii) 01 No Auto manual selector switch. 80 FEEDER FOR DIESEL ENGINEPUMP01 Noa) 20Amps DP MCB - 01 No b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 1 Noc) 1 set of indicating lamps for the following : 1.phase indication2.battery charger on3.over load relay4. DC supply on 5. control switch on 6. Engine fails to start 7. Pump on8. Low oil pressure9. High water temperature10. Auto manual selector switch d) 1 sets of push button stations for the following : 1. Engine Start2. Engine Stop 3. Engine - hooter ACK4. Engine - fault resete) Selector switches (Engine control, mode selector)-1 Nof) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set.g) Hooter for audio alarm (Industrial type) - 1 NoNote: All the components shall be housed in a common cubical made of 2.0 mm thick M.S. sheet with required stiffeners (if required). The panel shall be powder coated of approved color both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. 81 Supply, Installation, Testing and commissioning Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm burieddirectly in ground vertically at a depth not less than 2.25 m below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level sourrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filled in alternate layers etc and connected to and including 32 x 6 mmGI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm bore GI pipe connected to main control board and GI pipe medium grade 15 mm bore for watering and including funnel, wire mesh, charcoal salt etcRCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20 mm graded aggregate)including excavation and earthwork, disposal of surplus soil to a distance not exceeding 50 m and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and directed. 82 Supply and fixing earth continuity conductor or main earthing lead made of Galvanised iron strip of size 32 x 6 mm complete all as specified & directed. 83 SCHEDULE "A" PART-IV (Fire Hydrant System) :Supply and Install Electric Driven Jockey pump horizontal end suction centrifugal type Confirming to IS-12469 : 1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with non over loading power characteristics for frequent start/stop operations for 440V, 3 phase, 50 Hz 70m head 180 LPM discharge complete all as specified and as directed. 84 Supply and Install Electric driven Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz, suitable for delivering 2280 LPM, 70 meter head,2900 RPMtesting and commissioning complete all as specified and as directed. 85 Supply and Install Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with "range of operation" 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 70 m Head. 2280 LPM, 1800 RPM testing and commissioning complete all as specified and as directed. 86 Supply and fix MS flanged pipe 150mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer 87 Supply & fix fire hydrant landing valve type A (double head outlet) of 63 mm dia conforming to IS 5290 88 Supply and fix hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm 89 Supply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness 90 Supply, Installation, Testing and commissioning of GM foot valve of size 150 mm bore, conforming to relevent IS 4038 specifications complete as specified. 91 Supply and fix 150mm bore cast iron sluice valve with flanged ends heavy duty class PN-1.6, ISI marked, drilled holes for bolt, comprising of SS spindle and cast iron operated handle including necessary rubber gasket joint with nut and bolts complete all as specified and directed. 92 Supply and fix incl testing and commissioningValve, butterfly conforming to IS 13095,50 mm (2”) dia. 93 Supply and fix incl testing and commissioningValve, butterfly conforming to IS 13095,50 mm (3”) dia. 94 Supply and fix incl testing and commissioning Valve, butterfly conforming to IS 13095,50 mm (6”) dia. 95 Supply and fix incl testing and commissioning fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 96 Installation fixing incl testing and commissioningof fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290, (Note:Only Fire hydrant will be isued under Sch B free for fixing, accessories gasket nut boltany spare to required to make functional will be provided by contractor and quoted rate deemed to include same) 97 Supply and fix Gun metal fire brigade in let connection for connecting to external fire hydrant ring main consisting of two nos 63mm dia instantaneous type male coupling with built in check valves and 150mm dia, flanged outlet complete with all accessories. 98 Supply and fix 150mm bore cast iron non return valve with flanged ends heavy duty (IS-5312), class PN 1.6, drilled holes for bolt, including necessary rubber gasket joint with nut and bolts complete all as specified and directed. 99 Supply and fix 100mm bore cast iron non return valve with flanged ends heavy duty (IS-5312), class PN 1.6, drilled holes for bolt, including necessary rubber gasket joint with nut and bolts complete all as specified and directed. 100 Supply and fix 80mm bore cast iron non return valve with flanged ends heavy duty (IS-5312), class PN 1.6, drilled holes for bolt, including necessary rubber gasket joint with nut and bolts complete all as specified and directed. (01x Water Supply & 01x Fire fighting) 101 Supply installation testing and commissioning of MS ERW 80 mm bore with all fittings fixed in wall floor or in trenchescomplete all as specified and directed. 102 Installation testing and commissioning onlyof MS ERW 150mm bore with all fittings fixed in wall floor or in trenchescomplete all as specified and directed. 103 Installation testing and commissioning onlyof MS ERW 100mm bore with all fittings fixed in wall floor or in trenchescomplete all as specified and directed. 104 Installation testing and commissioning onlyof MS ERW 80mm bore with all fittings fixed in wall floor or in trenchescomplete all as specified and directed.(Notefor installation only ERW pipe item :Only MS ERW pipewill be isued under Sch B free for fixing, accessories gasket nut boltany spare to required to make functional will be provided by contractor and quoted rate deemed to include same) 105 M&L for Pressure switch Universal type 106 M&L for Pressure gauge 4"dial 0-14 kgs rating 107 Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete 108 Material and labour for re- development reaming in bore of 150 mm dia casing pipe exceeding 120.0 Feet depth below ground level and upto 40 RM in any kind of soil strata including hard stone/boulder including Yield test for the bore well by continuously pumping for 08 hours to determine safe pumping yield clear water as the testing report to be submited to this office in all respect complete all as specified and as directed. 109 Supply and fix PVC Casing pipe thread type 150mm bore including necessary fixing arrangement complete all as specified and as directed. 110 Installation testing and commissioning onlyof PVC Casing pipe thread type 150mm bore including necessary fixing arrangement with all fittings and fixing arrangement complete all as specified and directed.(Note:Only cassingpipewill be isued under Sch B free for fixing, accessories gasket nut boltany spare to required to make functional will be provided by contractor and quoted rate deemed to include same) 111 Installation testing and commissioning onlyof stainer thread type 150mm dia including necessary fixing arrangement with all fittings and fixing arrangement complete all as specified and directed.(Note:Only stainer will be isued under Sch B free for fixing, accessories gasket nut boltany spare to required to make functional will be provided by contractor and quoted rate deemed to include same) 112 Supply and fix PVC boring pipe Thread type 80mm dia with complete fitting & accessories complete all as specified and as directed. 113 Supply and fix check valve 80mm bore including fixing arrangement complete all as specified and as directed. 114 Supply and fix MS reducer, bail plug, well cap, MS strip for centering, MS iron clamps, electric logging and sample strata box. 115 Supply and fixSand grade 16/30 (Baraker River sand)including fixing arrangement complete all as specified and as directed. 116 Supply, Installing and testing and commissioning Monoblock pump set suitable for 415 V, 50 Hz ,3 phase system having capacity 10 HP, suction and delivery of maximum 700 LPM 33 meter head, section and devilery 80x80mmmotor and pump with all accessories complete with making connection including testing and commissioning completeall as specified and as directedNote :- 01 is running and other is standby. 117 Supply and fixing fully automatic star delta monoblock starter for 10 HP, 415Volt,. 50Hz, 3 ph motor including making connection complete testing and commissioning complete all as specified and as directed. 118 M & L for 90 mm outer dia 3-layer PP-R polypropylene random copolymer pipes concealed pipes SDR 11 (PN-10) UV stabilised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random and complete fittings laid in trenches PP_R Polypropylene random copolymer pipes concealed pipe SDR 11 (PN-10) and connection complete from complete all as directed. 119 Supply , laying and testing cable , PVC insulated electric cable 1100 Volts grade with Flat 3 core 10 Sqmm copper cable including making connection complete all as specified and as directed. 120 Installation fixing incl testing and commissioningof PVC insulated electric cable 1100 Volts grade with Flat 3 core 10 Sqmm copper cable including making connection complete all as specified and as directed.(Note: Only 3 core 10 Sqmm copper cablewill be issued under Sch B free for fixing, accessories gasket nut bolt connectorsany spare to required to make functional will be provided by contractor and quoted rate deemed to include same) 121 Supply and fix 80mm bore cast iron sluice valve with flanged ends heavy duty class PN-1.0, ISI marked, drilled holes for bolt, comprising of SS spindle and cast iron operated handle including necessary rubber gasket joint with nut and bolts complete all as specified and directed. 122 M &L construction of valve pit chamber (Masonry) of size 90 cm x 90 cm x 90 cm depth (internal dimension) with sub class `B" bricks one brick thick wallin cement mortar (1:4)10 ,mm thick plastering in cement mortar 1:4, PCC (1:4:8) type D-2 in foundation 150 mm thick,PCC (1:3:6) type C-1 as in bedding10 mm thick, PCC (1:2:4) type B-1 in coping 10 mm thickincluding (40 x 40 x 6)mm MS angle iron frame, 3 mm thick MS cover plate with locking arrangement and painting to all steel surfaces with two coats of synthetic enamel paints over a coat of red oxide primer including surface preparation and necessary earth work and removal of spoil/rubbish upto a distance not exceeding 50 mtr and levelling as directed. 123 M& L forCross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. 124 M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in base of pole or in any suitable complete all as specified and directed. 125 M&L concealed point wiring complete with 1.5 sqmm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metalic PVC rigid conduit medium grade of 20mm dia and conduit accessories and fittings like bend, elbows, crosses wall crossing etc. including cutting, chasing and pinning fixed on wall, floor, roof for one light/exhaust fan/call bell point controlled by one way 6 Amp modular switch and including provision of PVC insulated FRLSH 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet, fan regulator etc, including testing on completion etc all as specified and directed by Engineer-in-charge. 126 All as per item No 1 here-in-before but for ceiling fan point controlled by switch and regulator. 127 All as per item No 1 here-in-before but 2.5 Sqmm PVC insulated and unsheathed copper conductor for switch socket combination 5 pin 15 Amps on independent board. 128 Supply and fix Modularwhite cover plate with frame , 3 module complete as specified and directed. 129 Supply and fix Modularwhite cover plate with frame , 6 module complete as specified and directed. 130 Supply and fix Modularwhite cover plate with frame , 2 module complete as specified and directed. 131 Supply and fix Modularmetal flush box , 2 module complete as specified and directed. 132 Supply and fix Modularmetal flush box , 3 module complete as specified and directed. 133 Supply and fix Modularmetal flush box , 6 module complete as specified and directed. 134 M&L modular switch single pole one way 6 Amps, 1 module complete all as directed by Engr-in-charge. 135 S&F Modular switch 1 way 16Amp , 1Module complete all as specified and as directed 136 S&F Modular Socket 6A/16A - 2/3 pin combined 2Module complete all as specified and as directed. 137 M&L ceiling rose, three terminal single phase / PVC/Polycarbonate isolated body complete all as specified and as directed.(Note: 02Nos Ceiling Rose is considered for Building Security Lights) 138 S&F Fan step regulator, 120W - 2 module complete all as specified and as directed. 139 Supply and FixDB sheet metal enclosure for DBs when MCB to be used for 240 volts, 8 way with 200 amps rated bus bar including earth and neutral link, SP & N double door, complete all as specified and as directed. 140 Supply and fixing amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of 32 Amps SPN including making connection complete all as directed. 141 Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. 142 Supply and fixing LED light fitting 1X 20 W , 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified and directed by Engr-in-charge. 143 Supply and fixing LED light fitting 1X10 W , 220 V, AC bulk head luminairesincluding LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete as specified and directed by Engr-in-charge. 144 Supply and fix Lamp holder , PVC /Poly carbonate type with back plate suitable for batten fittings including LED bulb10W complete as specified and directed by Engr-in-charge. 145 S&FLED light with pressure die-cast housing with toughened glass along with prismatic polycarbonate diffuser and LED"s with secondary optics for better light distribution and IP-66 protection of 30 watt, Efficacy > 110 lumens/Watt for building security light including bracket 1.2m long made of GI pipe 40mm medium grade, complete all as specified and directed by Engineer in charge. Make : SuryaModel NEWGEN Cat Part No.SLE UL 30W IP66 NGN or equivalent in crompton/ Philips /Havells. 146 M&Lfor Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts nuts, check nut and washers of GIand GI tubing 15mm bore, medium grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm reinforced with 8 mm dia TMT bars 100 C to C including one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing medium grade for watering ,charcoal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I. 147 Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed. 148 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades , frame and louvers, complete all as specified and directed.
|