Analysis Apparatus – Lcms System. Drug Analysis Device - Device For Carrying Out Toxicological Studies Functional Lcms Triple Quad System Including Installation And Training Lc System Maximum Operating Pressure: 1,300 Bar Lc System Binary High Pressure Gradient With Additional Third Pump Lc System At Least Two Pumps Of Which With 4-Fold Solvent Selection Lc System Autosampler: >150 Samples With 1.5 Ml Vials Lc System Column Oven With One Valve At Least Six Column Positions Lc System Further Valve For Integration Of Online Spe Including Accessories Installed In The Oven Lc System Waste Valve Can Be Controlled Directly And Via Software Vacuum Pumps Number Of Fore-Vacuum Pump(S) And Turbo Pump(S), May Be A Maximum Of One Pump, For Low Operating Costs Due To Reduced Pump Requirements Vacuum Pumps Cleaning Of The Ion Unit Must Be Able To Be Carried Out By The User, In Vessels Up To A Maximum Of 1 L, In Order To Keep Solvent Consumption Low Vacuum Pumps Easy Maintenance Without High Vacuum Interruption: Ion Inlet Cleaning From Normal To High Pressure Range Must Be Possible Without Vacuum Breaking Mass Spectrometer Triple Quadrupole Mass Spectrometer Mass Spectrometer Scan Speed: Up To 30,000 U/S With A Standard Resolution: R < 0.7 Fwhm, Adjustable To 0.5 U Mass Spectrometer Simultaneous Mrms: > 550 Transitions/Second Mass Spectrometer Ion Sources: Esi With Combination Source Esi And Apci Mass Spectrometer Mass Range: M/Z 2-2,000 Mass Spectrometer Minimum Pause: ≤ 1 Ms, Dwell Time: < 1 Ms Mass Spectrometer Soundproof Box For The Backing Pump(S) Mass Spectrometer Installation Standards Including Mass Spectrometer Lc Compatibility: Required Lc Flow Rates: Up To 2 Ml/Min Sensitivity Esi Positive: 1 Pg Reserpine (Fia), S/N > 2,000,000:1 (Rms) Sensitivity Esi Positive: 1 Fg Reserpine (On-Column), Idl ≤ 0.2 Fg Sensitivity Esi Negative: 1 Pg Chloramphenicol (Fia), S/N > 2,000,000:1 (Rms) Sensitivity Esi Negative: 1 Fg Chloramphenicol (On-Column), Idl ≤ 0.2 Fg Measuring Modes Q1/Q3 Scan, Sim, Mrm Measuring Modes Mrm-Triggered Production Scan Measuring Modes Precursor, Product And Neutral Loss Scan Polarity Change Changing Time: ≤ 5 Ms Incl. Stabilization, Positive And Negative Measurement Possible In One Run Software Control And Evaluation Software Software Software For Multi-Data Evaluation With Integrated Spectrum Library And Score Output Of The Library Comparison Software Pc With Monitor And Excel System Compatibility & Operation Control Of Lc And Ms In One Platform System Compatibility & Operation Representation Of Mrm Individual Spectra And Spectra Comparison Must Be Possible In The Software System Compatibility & Operation Gases Available For Operation: Nitrogen (N₂) Purity: 98%, Argon, Dry, Oil-Free Compressed Air System Compatibility & Operation Maximum Installation Depth Ms 60 Cm Data Quality & Safety In The Software Must Be Able To Flag, E.G. For Limit Values, Rt And Ion Ratio Deviations, Data Quality And Security, Automatic Highlighting Of Conspicuous Chromium
Contact Information
Contact No.
09419411344
Email
georg.weinfurtner@medbo.de
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 105090566
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.