|
Tender For Provision Of Barrack , Cook House, Bathroom And Toilet At Shillong Under Ge Shillong; 2 Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I 3 Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule "A" Part-II. 4 Lumpsum price worked out by the bidder/ tenderer forINTERNAL ELECTRIFICATIONas listed in Schedule "A" Part-III 5 Lumpsum price worked out by the bidder/ tenderer for HOT WATER SUPPLY as listed in Schedule "A" Part-IV. 6 Lumpsum price worked out by the bidder/ tenderer for REFRIGERATION as listed in Schedule "A" Part-V. 7 Lumpsum price worked out by the bidder/ tenderer for LIFT as listed in Schedule "A" Part-VI. 8 Lumpsum price worked out by the bidder/ tenderer for DG SET as listed in Schedule "A" Part-VII. 9 Lumpsum price worked out by the bidder/ tenderer for ROAD , CULVERT AND HARDSTANDING as listed in Schedule "A" Part-VIII 10 Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule "A" Part-IX. 11 Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule "A" Part-X. 12 Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule "A" Part-XI. 13 Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule "A" Part-XII. 14 Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL , FENCING AND GATE as listed in Schedule "A" Part-XIII. 15 Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule "A" Part-XIV. 16 Sch "A" Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. 17 S&F LED type bed side wall mounted light fitting 9/10 Watt , housing- glass, frosted type, metallic frame, adjustable type complete all as specified and directed. 18 S&F Modular blanking plate modular type suitable for fixing in modular switch board complete all as specified and as directed. 19 S&F Surge Protection Device (SPD) Single Phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in distribution board and making connections complete all as specified and directed 20 S&F Modular modular type TV socket RJ46, 1 module complete all as specified and as directed. 21 S&F Modular modular type TV socket RJ 11, 1 module complete all as specified and as directed. 22 S&F power unit suitable for up to 2.00 Ton AC having push ON-OFF button switch, motor starter type, single phase, 4 module with and including modular metal flush box with cover plates complete all as specified and directed. (For AC) 23 Supply, installation, commissioning and testing of Indoor type LT feeder piller box of size 1.5 m x 1.5 m x 0.50 m ,indoorcubical type, floor mounted,totally enclosed with front and rear opening, hinged doors with projected and raised platform of suitable size, dust and vermin proof material including as per IS 8623 aluminium bus bar with insulators suitable for three phase and four wires LT AC, 50 Hz, 415 Volts, 400 Amp capacity factory made of CRCA Sheet 2.0 mm thick powder coatedand MS angle of size 40x40x5mm having suitable legs, double door both side openable with locking and key arrangement with two Nos pad lock50 mm complete all as directed and comprising of the following:- (For single living ORs Accn 11 Hav & 169 ORs)(a) INCOMING(i) MCCB, 4 Pole, 415 Volts, 250 Amps, breaking capacity 36 KA with microprocessor release - 01 No(ii)LED indicating lamp with holder for main supply indicating RYB (set of three) - 01 Set(iii) On load change over switch 3 phase, 4 wire system, AC, 50 Hz, 400 Amp capacity - 01 No.(iv) Housing and making connection of 3 phase, 4 wire CT operated smart energy meter. ( CT operated smart energy meter catered here in after)(b) OUTGOING(i) MCCB, 4 Pole, 415 Volts, 100 Amps, breaking capacity 16 KA adjustable type - 05 Nos ( 04 Nos for floor & 1 No. as spare)(ii)Digital multifunction meter of size 96 x 96 mm to measure current, Voltage, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port.(iii) Aluminium bus bar of rating 400 Amps, insulated, 3 phase, 4 wire system. 24 Supply , installation, testing and comission of Smart energyMeter (IS-16444), AC whole current, three phase, 4 wires CT Operated Smart Energy Meter of Class 0.5 S, 415 Volts, 50 Hz, 1b 5 A complete as specified in CEA notification.The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technolog. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangement of suitable size as per the requirement of OEM of Electric meter. The cost of meter would be included the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 HZ and voltage class 660 Volts effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete all as specified and directed. NOTE:(a) The bidder shall provide replacement warranty of 5 Years from the date of activation of smart meter for any type of Defect/ Fault/ Error in reading/ Non functioning of smart feature.(b)CT to be provided at incommer side of MCCB in main LT panel of the Building. 25 Supply , installation, testing and comission of Smart energy prepaid Meterconfirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology and carry min 5 yrs warranty. 26 S&F perforated cable tray standard type C, made out of hotdip galvanised sheet having thickness not less than 1.2 mm thick foxed on wall up to 4th floor high building including necessary bracket for fixing and all accessories like bend, elbow etc suitable for housing single cable up to 25 Sqmm 4 core at each floor complete all as specified and directed. 27 Supply Installation and testing of Refrigerator double door run on digital inverter technology with latest specification or features of capacity 320 Ltrs with 5 star rated complete all as specified and directed 28 S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 V to 280 V with output voltage stabilized at 230 V with accuracy of+ 2.5% and of cap 4 Amps ( 1.0 KVA) complete all as specified and directed. 29 Design, Supply, Installation, Testing and commissioning incl comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 30 KWp (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications asgiven in particular specification (Detail Brief Report and Technical Specification for SPV Plant) complete all as specified and directed 30 Design, Supply, Erection, Testing and commissioning incl comprehensive maint for 7 years of Roof Top Solar Power Generation Plant of capacity 10 KWp (AC) at output Voltage 415 Volt, 50Hz, ON GRID Hybrid solar roof top with batteries back up for captive use as per specification & complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications andtechnical specifications asgiven in particular specification (Detail Brief Report and Technical Specification for SPV Plant) complete all as specified and directed 31 Design, Construction, Supply, installation, testing and commissioning of compact & concealed designed Sewage Treatment Plant of capacity 20 KLD based on Johkasou technology / (MBBR) Moving Media Bio Reactor Technology / PeMBR technolgyincluding fully automation system (Scada System), modular Pre- constructed systems having sedimentation and seperation chamber, anaerobic contact media chamber, moving bed chamber (Aerobic), sedimentation chamber, disinfectant chamber and tertiary treatment plant, including operation and maintenance for a period of 5 years from the date of completion of work including all consumable except power, with adequate manpower to ensure no downtime of plant and provide consistent outlet parameters, the plant shall be having least energy and operating cost and No noise during operation, complete and including the following:- 32 Continued serial item No. 15.015(a) Bar screen (Mesh) 500mm x 500mm, made of MS FRP coated, and bar spacing 10 mm complete as per OEM recommendations.(b) Cylindrical type reactor made of FRP complete as per OEM recommendation.C)Air blowerofcapacityas per OEM recommendations complete - 03 Nos.(d) Filter Feed Pump , Non-clog submersible pump of capacity as per OEM recommendations - 02 Nos ( One working + One Standby).(e)Pressure sand filter ofcapacity as per OEM recommendations, made of FRP, having vessel size 18" dia x 65" height and having Gravels/Pebbles/Core Silex/Fine Silex/ Sand as filter mediacomplete with necessary PVC piping complete - 01 Set.(f) Activated Carbon filter of capacity as per OEM recommendations, made of FRP, having vessel size 18" dia x 65" height and having 1200 I/V Activated carbonfilter mediacomplete with necessary PVC piping complete - 01 Set.(g) Chlorine (Sodium Hypochlorite Dosing) System having Dosing pump of capacityas per OEM recommendations and including HDPE Dosing drum of minimum cpacity 50 Litrs complete - 01 Lot.(h) Raw sewage Transfer Pump of capcity as per OEM recommendations complete - 02 Nos ( One working + One Standby).(j)One No. PLC Panel for operation of the plant as per OEPL standard & cabling with in the plant range complete.(k)Necessary piping & valves as per OEM recommendations within the plant range complete - 01 Lot(l)All as per Scope of Work & Technical Specification for 20 KLD STP given in particular specification 33 Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 28 KW 35 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 6 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering28 KW(35 KVA) atoutdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . 34 Continued serial item No. 15.016(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 28 KW(35 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi)Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: - Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn. 35 Continued serial item No. 15.016Note: PCC foundation for DG Setshall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user"s manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer"s drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil. 36 Supply, fixing and testing DI fittings for spigot and socketed or flanged pipes i.e bends, reducers, tail pieces, tapers, tees, collars, caps, plugs with MS plate, nuts, bolts, washers, gaskets etc of sizes 80 mm to 150 mm dia complete all as specified and directed. 37 M&L for construction of brick masonry valve pit of size 900 x 900 x 900 mm(internal dimension) one brick thick wall in CM (1:4) on 100 mm thick PCC (1:4:8) type D-2 (40mm graded crushed stone aggregate)foundation, 15mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below GL, providing valve pit cover made of 3 mm thick MS sheet/plate, providing and welded hinges, handle , locking arrangement, 50 X 50 X 6 mm angle iron frame fixed on top of valve pit by means of 4 Nos of hold fast 150 mm long, embedded in PCC block (1:2:4) type B-1 (20mm graded crushed stone aggregate) of size 230 x 200 x 100 mm and applying two coats of synthetic enamel paint over a coat of red oxide primer includingnecessary earth work in soft/loose soil complete all as specified & directed. 38 Cutting road upto one feet depth for insertion of cable protection pipe complete all as specified and directed.Note: cable protection pipe and PCC for refilling will be measured and paid separately 39 Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Outdoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour with necessary insulators for incoming/outgoing MCCB’s including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20 mm graded crushed stone aggregate up to 30 cm complete as per IS 8623, IEC 60947 & IS 13947: 1993 complete all as specified and directed. (Panel 1)(a) INCOMING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 250 Amp with breaking capacity 36 KA 40 Continued serial item No. 15.020(ii) Smart energy Meter(IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter ofClass 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(iii) Phase indicator lamps (RYB) - 01 set(b) OUTGOING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 200 Amp with breaking capacity 25 KA- 01 No (to panel 2)(ii)MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 160 Amp with breaking capacity 25 KA- 02 Nos (to barrack 1W+1S)(iii) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 63 Amp with breaking capacity 16 KA- 01 No (CH and DH)(iv) MCB TPN 20 Amps 10 KA - 01 No (C-Curve) (Street light)(v) Digital timer-01 No(vi) Power contractor -01 No 41 Fabrication, supply, installation, testing & commissioning of electrical cubical control panel board (PTTA Panel) factory assembled weather, Dust & Vermin proof, totally enclosed IP-54 protection floor mounted Outdoor factory fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase, 4 wire, 415 Volt AC, 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium bus bar insulated with FRP heat shrinkable sleeves of relevant colour with necessary insulators for incoming/outgoing MCCB’s including and mounting measuring instrument such as voltmeter, Ammeter, CT’s Phase LED indicator lamp R-Y-B, selector switch for incoming, cables connection with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20 mm graded crushed stone aggregate up to 30 cm complete as per IS 8623, IEC 60947 & IS 13947: 1993 complete all as specified and directed. (Panel 2)(a) INCOMING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 150 Amp with breaking capacity 36 KA 42 Continued serial item No. 15.021(ii) Smart energy Meter(IS-16444), AC whole current, three phase, 4 wires, CT operated Smart Energy Meter ofClass 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transperent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660V effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete - 01 No(iii) Phase indicator lamps (RYB) - 01 set(b) OUTGOING(i) MCCB 4 pole, 415 V, Microprocessor based, Adjustable type, 63 Amp with breaking capacity 25 KA- 03 Nos (to JCO single living & OC office)(ii)MCB 4 pole, 415 V, 32 Amp with breaking capacity 10 KA- 01 No (to store)(iii) MCB TPN 20 Amps 10 KA - 01 No (C-Curve) (Street light)(iv)Digital timer-01 No(v) Power contractor -01 No 43 S&F PVC Junction box of size 270 X 225 X 135 mmwiith 2 way connector mounted on epoxy insulators for looping of cablefor 1Phase and1neutral fixed on polewith the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X4 mm thick . Work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of 1.0 sqmm 3.0 core flexible PVC insulated copper cable from junction box to conector of street light complete all as specified and directed. 44 M&L for DWCP HDPE pipe SN 8 ,100 mm dia complete all as specified and directed. 45 S&F galvanised concertina razor wire BTO 22 galvanised steel, core wire diameter 2.5 mm dia, blade thickness 0.5 mm, length 22 mm, width 15 mm, number of loops 33 , clips per spiral 03 numbers, stretch length 8 to 10 meter per roll, breaking load 150 to 160 Kg/Sqmm , weight per roll 11.50 Kg, dia of roll 450 mm should be packed in water proof paper and wooden box complete all as specified and directed. 46 Construction ofRCC bridge (Two lane) of size 18 m span and 5.50 m width complete allas specified and shown on drawings.
|