Tender For Provision Of Certain Revenue And Minor Works At Afs Sulur - Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in hard/dense soil, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed. 3 Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed. 4 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. 5 M&L for PCC 1:4:8 typeD-2 plain Cement concrete in foundations, filling and mass concret all as specifid and directed. 6 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. 7 S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats,gusset plates,wind ties etc of Fe410- W(GdeE-250) quality-B complete all as specified and directed. 8 S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 9 S&F for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified 10 M&L for Hard core of gauge not exc 63 mm size depositing spreading , leveling watering and well ramming with broken stone boulders / stone specified 11 M&L 100 mm thick PCC 1:3:6 type C-2using 40 mm graded stone aggregate as in floors surface finished cement surface all as specified and directed. 12 M & L for Screed bed or bedding layer of cement plaster 1:6mortar 15mm thick for laying floor finishes complete all as specifed and directed. 13 M & L for Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed. 14 M&L Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in kerbs, coping etc including necessaty formworkcomplete all as specifed and directed. 15 M&L Brick work with old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. 16 M & L 15mm thick cement plaster in CM (1:6) on fair faces of brick or concrete surfaces lf wall and finished even and smooth without using extra cementcomplete all as specifed and directed. 17 M & L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. 18 M&L for preparation of untreated new surfaces of steel and iron work exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 19 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cmcomplete all as specifed and directed. 20 Removing excavated soil in hard/dense soil exc 1.50 Km and not exc 5.00 Km out side the campus including loading and unloading etc., where responsibility regarding place of deposition and permission from all authorities etc., in this regard will be of contractor and allas specified. 21 M&L forPCC 1:2:4type B1using20 mm graded stoneaggregateas in pillars, post holes and mass concrete complete all as specifiedand directed 22 S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted , bolted or welded attachment. (Fe 410 -W (Gde- E-250) quality -A complete i all as specified and as directed. 23 M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other to be fitted with washers and one hexagonal or square nuts, n exc 5cm long diameter of neck 5 to 10mmcomplete all as specified and as directed. 24 Dismantling of false ceiling boarding, any description, fixed or laid /inserted incl timber /GI/ aluminium frame work with screws in ceiling flat or slopingcomplete all as directed. 25 Providing and fixing 6mm thick fibre cement designer false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit. 6mm thick High Pressure Steam Cured Non Everest Asbestos Fibre Cement Designer Ceiling Board (Density>1200 Kg/m3, Modulus of Rupture(M.O.R)-15.85 MPa, Thermal Conductivity(K)-0.0872 W/mK) of size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336:1993, (Reaction to fire-A2-s1-d0) tested as per EN13501 Part-I & BS-476 Part 4,5,6&7, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of engineer-in-charge. 26 Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not packing) removing of serviceable tiles to store and rubbish off the premises complete all as specified 27 S&F Coloured Non Skid ceramic tiles7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:4)complete all as specifed and directed. 28 M&L glazed coloured ceramic tiles in vertical surface 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in colour cement to match and 10 mm thick rendering in cement mortar 1:3complete all as specifed and directed. 29 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed offine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specifed and directed. 30 Taking down chowkatsor framesnot exceeding1.5 Sqmeachbut with shutters (without taking off shutters from the frames) all as specified. 31 Supply and fixing factory made uPVC white colour fixed glazed window/ ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance inimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 32 M&L Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 33 M&L Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately) 34 S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) white (excld flushing cistern & Pipe) including connection to trap and flushing pipe complete all as specified & directed. 35 S&F in repairs PVC (EWC)seat cover white colour with flat bottom including CP hinges complete all as specified and directed. 36 S&F in repairs 10 lit PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets all as specified and directed. 37 S&F in repairs vitreous china wash down couple water closetbowl with cistern for coupled WC with UF soft close slim seat cover, inges dual flush cistern fittings and fixing accessories, of size 365x630x750mm incl P trap complete all as specified & directed.Make : Cat NoFNS WHT- 40751P180UFSMZ of Jaquar or equivalent 38 S&F in repairs wash hand basinvitreous china white flat back of size 550 X 400mm with brackets,including CP pillar tap fancy type of 15mm bore complete all as specified and as directed. 39 S&F in repairs wash hand basinvitreous china wall hung basin with full pedastal incl fixing accessories complete all as specified and as directed. Make :Cat NoLYS-WHT-38801 of Jaquar or equivalent 40 S&F in repairs Pillar tap of 15mm dia chromium plated cast copper alloy of fancy typescrewed down for iron pipecomplete all as specified and directed.Make : Cat No : ARI-CHR-39011 of Jaquar or equivalent 41 S&F in repairs Brass Chromium plated waste coupling of 32 mm dia with screwed shank and fly nuts complete all as specified and directed. 42 S&F in repairs PVC connections 15mm size with PTMT nuts and washersfor 450mm long pipe complete all as specified and directed. 43 S&F in repairs 110 mm dia PTMT grating doom(min. weight 25 gms) complete all as specified and directed. 44 S&F in repairs Bib taps of 15mm dia chromium plated cast copper alloy of fancy typescrewed down for iron pipecomplete all as specified and directed. 45 S&F in repairs Bib taps of 15mm dia chromium plated cast copper alloy of fancy typescrewed down for iron pipecomplete all as specified and directed.Make : Cat No ALI-CHR-85037 of Jaquar or equivalent 46 S&F in repairsstop valves of 15mm dia cast copper alloy CP fancy type screwed down high presure screwed at the ends for iron pipe or union with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixedcomplete all as specified and directed. 47 S&F in repairs bevelled edge looking mirror of size 600X450mm of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixedto wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 48 S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 49 S&F in repairs Brass CP tubular towal rail of 20mm dia , D type, 600mm long complete all as specified and directed. 50 M&L in repairsPVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cementcomplete all as specified and directed. 51 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre lineover fittings and accessories)complete all as specified & directed. 52 S&F 75 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed 53 All as per item No 52 above but 110 mm dia. 54 S&F 75 mm bore PVC (SWR) bend any radius complete all as specified & directed. 55 All as per item No 54 above but 110 mm dia. 56 S&F PVC (SWR) branch pieces single Y equal or unequal 75mm bore complete all as specified and directed 57 All as per item No 56 above but 110 mm dia. 58 S&F 75mm bore PVC (SWR) vent cowl complete all as specified & directed. 59 S&F 110mm bore PVC (SWR) vent cowl complete all as specified & directed. 60 M & L for cement concrete in copings,bands, etc.PCC 1 : 2 : 4 type B0 (12.50 mm graded stone aggregate) including necessary form work, weathering, slightly rounded or chamferred angles and throating complete all as specified and as directed. 61 M & L for Rendering in CM 1:4, 15 mm thick on other than fair faces of brick work or concrete surfaces finished with even and smooth without using extra cement complete all as specified and as directed. 62 Material and labour for TMT bars, 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed )not less than 0.9mm dia complete all as specified and as directed. 63 Material and labour for TMT bars, 8 mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed )not less than 0.9mm dia complete all as specified and as directed. 64 M& L for precast cement concretetype B1 1:2:4 (20 mm graded stone aggregate) in cover slab etc set in cement mortar 1:4 includingall necessary form workcomplete all as specifed and directed.Note : Reinforcement will be measured and paid separately under relevant items here in after. 65 M&L for 100 mm thick PCC 1:4:8 type D-2using 40 mm graded stone aggregate as in floors surface finished cement surface complete all as specified and directed. 66 M&L Precast cement concrete solid block masonry (1:3:6 type C-1,20mm graded stone aggregate) exc. 10 cm in width and setting in cement mortar 1:4 complete all as specified and as directed. 67 M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering03045 Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed. 68 M&L 40 mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate Finished even & smooth without using extra cementcomplete all as specifed and directed. 69 M&L Vitrified Ceramic tiles 10 mm thick,dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over andincluding screed bed or bedding layer, 15 mm thick in Cement Mortar 1:4complete including dismantling of existing tile and disposal off to outside MD land complete all as specified and directed. 70 Demolition of brick/ stone masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and as directed. 71 M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 with smooth finish without using extra cementcomplete all as specifed and directed. 72 M & L preparation of new plastered or unplastered surface of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant priming paint complete all as specified and as directed. 73 S&F 100mm long butt hinges, medium weight, cold rolled mild steel, and fixedcomplete all as specifed and directed. 74 S&F 150mm long brass handles, cast type, polished brightcomplete all as specifed and directed. 75 S&F brass ,4 lever mortice lock, vertical type, size 100 mmcomplete all as specifed and directed. 76 S&F150 mm long brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specifed and directed. 77 M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates),as in plinth protection complete all as specified and as directed. 78 M&LPCC 1:2:4, Type B–1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedcomplete all as specified and as directed. 79 Material labour for point wiring complete with 1.5 Sqmm PVCinsulated unsheathed single core multi multistranded copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit on wall/ceiling and terminated to MS box of 1.6 mm thick and 3 mm hylum sheet for mounting switches sockets etc including 1.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly for light/ fan point three pin 5 Amp complete 80 One light point controlled by one way 5 Amps swtich 81 One fan point controlled by one way 5 Amps swtich 82 One 3 pin socket out controlled by one way 5 Amps swtich on independent board 83 Material labour for point wiring complete with 2.5 Sqmm PVCinsulated unsheathed single core multi multistranded copper conductor 1100 V grade drawn through in and including 25 mm dia PVC conduit on wall/ceiling and terminated to MS box of 1.6 mm thick and 3mm hylum sheet for mountingswitches sockets etc including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly for power point wiring complete 84 S&F switch paino 1-way 6 amps complete all as specifed and directed. 85 S&F switch paino 1 way 16Acomplete all as specifed and directed. 86 S&F switch socket combination 5 Amps 3/5 pincomplete all as specifed and directed. 87 S&F switch socket combination 15 Amps 3/5 pin multi purposecomplete all as specifed and directed. 88 S&F Fan step regulator, 120W - 2 modulecomplete all as specifed and directed. 89 S&F Sheet metal enclosure DB 230v,1-Ph,50hz,200Amps bus bar 8-way, double door complete all as specifed and directed. 90 S&F MCB SP,230Volts, 50Hz, current rating up to 6-32Amps complete all as specifed and directed. 91 S&F Isolator 230volts, 50Hz current rating up to 63Ampscomplete all as specifed and directed. 92 S&F MCB SP,230Volts, 50Hz, current rating up to 6-32Ampscomplete all as specifed and directed. 93 S&F Isolator 230volts, 50Hz current rating up to 63Ampscomplete all as specifed and directed. 94 S&F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid/surface/roof including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from notless than 110 lumens/watt.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection not less than 2KV ,permisible limit of CRI range,with recommended burning hours,4000K/6500Ketcfrequency 50 to 60 Hz ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , . PF should be notless than0.95 , THD < 10% . Indivisual LED"s should not be visible for glare free output ,colour temperature 6500k all as directed. 95 S&F of ceiling rose two three terminal surface backallite type complete all as directed by Engr-in-charge. 96 M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth wire of size 4 mm dia (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. 97 M&L for removing existing ceiling fans from its original location and cleaning ,servcing and greasing with approiate materials as directed and refixing the same on its original location with extended downrod including all necessary wiring ,nuts bolts complete all as directed , 98 Supply & fix industrial socket single pole and neutral enclosure with a two pin earth plug and socket 20 Amps complete with one double pole MCB complete (Male & Female connector) all as directed. 99 Sub main wiring for circuit complete with 2 X 4 sqmm single core PVC insulated, unsheathed FRLS1100 Volt grade multi stranded copper conductor cable drawn through and incl suitable size PVC Casing capping and accessories complete fixed surface to wall/roof/ceiling etc and incl 1 X 4 sqmm single core PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductoretc and all as specified: 100 Supply and fixing factory madepowder coated distribution board SPN 2 way, single doorincludingbus bar, Neutral bar, standard DIN rail, earth bar acomplete all as specified and directed 101 Supply andfixingMCCB 40 amp, 4 Pole 415 v, 50 Hz ACsuitable for 16 KA breaking capacitywith enclosure complete conforming to IS 8828 of 1996all as specified. 102 Supply & fix industrial socket triple pole and neutral enclosure with a three pin earth plug and socket 32 Amps complete incl male and female with one TPN MCB(Male and Female connector) complete all as directed. 103 M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable4 runs of 6 sqmm drawn through in and incl suitable steel conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. 104 Supply and Installation of Smart prepaid Single Phase Meter with the following specifications:• AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 with communication technology including GPRS / RF / Hybrid(GPRS+RF) / any other advanced technology as per CEA / TRAI regulations)& with BIS identification mark on Name Plate and relevant IEC standardson demand display, billing data generation facility, anti-tamper features,recharge tokens display, Microprocessor and LED/LCD based circuitry.• Meter Should support sending thethe following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand• Meter should have connect / disconnect functionality operable from prepaid billing software. The meter should be capable to intigrate with existing AMI server installed at Airforce station subroto park, meter installations shall be installed as per IS-16444MAKE: Secure, L&T, Schneider 105 Note for above item No.104:(a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES.(b) The contractor should responsible for intrigration of these new 16444 energy meters with existing AMI infra smart prepaid meter server installed at Airforce station subroto park including proviosion of all billing parameters, energy realated data,token genration which are available in exisitng software (i.e MES TVS server) (c) The meters would carry 10 year warranty.(d) Quoted rates deemed to be includes telecom netwrok charges,NB-IOT ,OTP charges for User and service provider & DLT charges during DLP period.(e)Quoted rates deemed to be includes OEM meter token genaration and same shall be reflected in meter and user accountduring DLP period.(f) Contractor should take MOU with existingM/S Secure server located GE AF at Subrata Park, Palam for maintainance of these meters installed at Airforce station sulur during DLP period.(g) Contractor shall be responsible for supply/planning/setup/tuning of network management & H&S for the existing AMI infra smart prepaid meter server for the meters catered in this job. Quoted rates deemed to be included. 106 Supply and Installation of Smart prepaid three Phase Meter with the following specifications:• AC three Phase four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444 with communication technology including GPRS / RF / Hybrid(GPRS+RF) / any other advanced technology as per CEA / TRAI regulations)& with BIS identification mark on Name Plate and relevant IEC standardson demand display, billing data generation facility, anti-tamper features,recharge tokens display, Microprocessor and LED/LCD based circuitry.• Meter Should support sending thethe following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand• Meter should have connect / disconnect functionality operable from prepaid billing software• The meter should be capable to intigrate with existing AMI server installed at GE AF palem, meter installations shall be installed as per IS-16444.MAKE: Secure, L&T, Schneider 107 Supply and lay UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100V with screened aluminium conductor of size 4 core 25 sqmm all as specified and directed. 108 Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and as directed. 109 M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cablecomplete all as specifed and directed. 110 Supply and lay Fire bricks, size 230 x113 x 75 mm for the protection of LT UG Cable in trenches complete all as specified and directed by Engineer-in-Charge. 111 M& L of GI pipe (Light grade) for protection of LT cable fixed to walls/poles/road crossing including clamps complete of 50 mm bore complete all as specified and as directed. 112 Supply, Install and commissioning LT Busbar chamber outdoor type IP-65 of size 0.6 X 0.6 X 0.45 Mtr made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with 200 A Aluminium bus bars and with suitable mounting plate, frame and canopy including foundation for busbar chamber to fix at min 1.5 feet above from ground level confirms to IEC61439-2 all as specified and directed. 113 Supply, Install and commissioning LT Busbar chamber outdoor type IP-65 of size 0.6 X 0.6 X 0.45 Mtr made out of 3.15 mm thick MS sheet and angle Iron frame work for accomodate four Nos of sheet metal enclosures with suitable mounting plate, frame and canopy including foundation for busbar chamber to fix at min 1.5 feet above from ground level confirms to IEC61439-2 all as specified and directed. 114 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20A double pole MCB inclding fixing at location all as specified and directed by Engineer-in-Charge. 115 M&L 3 core PVC insulated copper wire 2.5 Sqmm all as specified and directed by Engineer-in-Charge. 116 S&F 7.5 KVA Voltage stabilizer for automatic operation, single phase indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 240Volt with accuracy ± 1% adjustable including manual bypass arrangement complete all as specified and directed by Engineer-in-Charge.
|