|
Tender For Provision Of Stps At Ins Chilka; 1 Schedule "A" Part – I:-Sewage Treatment Plants(This schedule is not pre-priced by MES. Contractor has to quote his own rates.) 2 Design, Supply, Installation, Testing and Commissioning offully automatic Sewage Treatment plant(STP) of the under mentioned capacities with suitable technology as per geographic location, temperature differential and rainfall. The design of Plant can be either biological process or physical separation process with chemicals as secondary treatment process and must comply with the teritiary treated water parameter and also considering the points while designing the STP:- 3 900 KLD capacity 4 300 KLD capacity 5 200 KLD capacity 6 Designing, Supplying, Developing, lnstallation, Integrating and Commission STP SCADA System along with various Automation equipment for under mentioned STPs:- 7 900 KLD capacity 8 300 KLD capacity 9 200 KLD capacity 10 Schedule "A" Part – II toXI:NOTE: Schedule "A" Part – IIto Part – XI are prepriced by MES. 11 Lumpsum price worked out by the contractor for "BUILDINGS AND STRUCTURES",as listed in Schedule "A" Part – II (Refer pre priced schedule attached seperately). 12 Lumpsum price worked out by the contractor for "SITE CLEARANCE, AREA DEVELOPMENTAND EARTH WORK",as listed in Schedule "A" Part – III(Refer pre priced schedule attached seperately). 13 Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION",as listed in Schedule "A" Part – IV (Refer pre priced schedule attached seperately). 14 Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY",as listed in Schedule "A" Part – V (Refer pre priced schedule attached seperately). 15 Lumpsum price worked out by the contractor for "ROAD, PATH & HARD STANDING",as listed in Schedule "A"Part – VI (Refer pre priced schedule attached seperately). 16 Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY",as listed in Schedule "A" Part – VII (Refer pre priced schedule attached seperately). 17 Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION",as listed in Schedule "A" Part – VIII (Refer pre priced schedule attached seperately). 18 Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – IX(Refer pre priced schedule attached seperately). 19 Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - X(Refer pre priced schedule attached seperately). 20 Lumpsum price worked out by the contractor for "GATE, FENCING AND COMPOUND WALL",as listed in Schedule "A" Part – XI (Refer pre priced schedule attached seperately). 21 Schedule "A" Part - XII (Miscellaneous items) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. Contractor has to quote his own rates. 22 Miscellaneous items forInternal Electrification : 23 M&L for Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 25 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and modular GI Flush Box made out of suitable size and required module frame with top cover plate, for fixing modular switches, fittings, regulators, blanking plates etc. concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by one switch complete all as specified and as directed. 24 All as per Item Sl No - 16.01 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 5/6 A modular socket point on independent board complete.Note: One circuit with maximum 04 points 25 All as per Item Sl No - 16.01 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A modular socket point on independent board complete.Note: One circuit with maximum 01 points only 26 All as per Item Sl No - 16.01 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 4.0 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 4.0 sqmm green in colour as earth lead for 20 A metal clad socket point complete. Note: One circuit with maximum 01 points only 27 All as per item No 16.01 here in before but for one light point controlled by 2 way switches complete all as directed. 28 S&F LED bulb 10 watt B-22 230 volts complete all as specified. 29 S&F LED emergency inverter bulb 10 watt B-22 230 volts with atleast 4 hrs backup complete all as specified. 30 Supply & Fixing V-TPN DB with sheet metal enclouser, 06 way IP-43 with rated 250A fully insulated copper bus bar & shrouded neutal bars, double door suitable for MCCB as incommer and MCB SP/TP as outgoing withneutralbar,earthbar and cable tiles for cable managements, incl cutting chases for DB of reqd size and making good distrubed surface area complete all as specified and as directed 31 S&F MCCB, 4P, 16KA, 415V, with thermal magnetic protection, 25 to 100 A, ISI Marked complete all as directed. 32 S&F MCCB, 4P, 25KA, 415V, with thermal magnetic protection, 160 A, ISI Marked complete all as directed. 33 Miscellaneous items forInternal water supply 34 S&F for 15mm dia Two way Bib cock, cast copper alloy with wall flange and lever handle, screwed down, screwed for pipe or for unions and fixed complete all as specified and as directed. 35 S&F for Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25m long flexible and ABS wall hook including making connections and fixed in position complete in all reapect as specified. 36 Miscellaneous items forSewage Disposal 37 M&L for SRFC factory mademanhole cover square/rectangular/ circlar shape for using cover to maholes complete as directed. 38 Miscellaneous items forExternal Electric supply 39 S/F double wall corrugated ,High density polyethylene pipes (HDPE) of 100 mm dia laid in trenches walls, ceilings or in floors etc. complete all as specified and as directed by the Engineer-in-Charge complete. 40 M & L for drop out fuse assembly mounted on insulator and steel frame horizontal/vertical type for HT 11 KV lines including connections etc complete all as specifeid & directed. 41 Supply, installation, testing and commissioningof outdoor LT feeder pillar box panel board (2000 x1500 x 500 mm), CPRI Approved, made out of CRCA sheet 3.15 mm thick vermin proof factory made double doorwith 40 x 40 x 6 mm MS angle/channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comprising of high conductivity copper bus bar of capacity 160A three phase and half the capacity for neutral including voltmeter, Ammeter selector switches, PCC foundation suitable to accommodate the following as specified and as directed. Note One Nos of on load change over should be connected in series through bus bar for main supply and DG set. 42 INCOMING(a) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp 01 nos(incoming) complete and all as per standard pratice -1 Job(b) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 16 KA 1 Nos (INCOMMING). 43 OUT GOING(a) panel mounted on load Changeover 4 Pole, 415 V 100 Amps1Nos (b)MCCB 4 Pole, 415 V, Adjustable type,63 Amps with breaking capacity 16 KA 3 Nos (c)MCCB 4 Pole, 415 V, Adjustable type,40 Amps with breaking capacity 16 KA 3 Nos (d) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice-3 setNote :-(i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on - off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor (Incoming) and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per standard practice. 44 Supply and fixing in repairsenergy saving LED street light fittings,100 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED 5700K connecting up light fitting with copper conductor cable of suitable size from junction box to connector blockincluding all accessories and dismantling of old unserviceable fittingfor taking into credit complete all as specified and as directed.Make:Crompton LSTS -90-CDL-M( NEXUS NEO) or equivalent in Philips/Bajaj/ Wipro 45 Supply and fix weather prooflooping in box PVCwithout side dimension 160 x160x105 mm comprising of connector andMCB SP 6-32 A including mounting arrangementsandlugs etc.and removing existing defective looping box and taken as credit complete all as specified and as directed. Make :Sintex/Hensel or as specified in PS 46 Supply and fix new GI bracket made out of 25/32/40mm dia GI pipe length 1.2 mtr long bent to an angle 135 degreeincluding two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc including removing old unserviceable GI bracketcomplete allas specified. 47 Supply and install APFC PANEL with MD-LX capacitor 50 KVAR with 6 steps ( 2+3+5+10+15+15) and MCCB as incomer 48 Supply and fix fire extinguisher dry chemical powder (ABC) Type , capacity 6 kg, as per IS 15683 , all as specified and as directed. 49 Supply and fix fire extinguisher Mechanical foam extinguisher(stored pressure type) , capacity 9 ltrs, as per IS 15683 , containing 540 ml AFFF liquid ISI marked,IS 4989 part -II and polyurethane caoted CO2 gas cartridge ISImarked 4947 complete with gun metal,union cap, nylon hose with plastic foam making branch and wall mounting bracket all as specified and as directed. 50 Miscellaneous items forExternal Electric supply 51 Supply, laying ,jointing and testing 2"/63 mm bore HDPE pipe, PR-100 grade including fittings such as bends, socket, reducer, elbows, union etc in trenches complete all as specified and directed. 52 Supply, laying ,jointing and testing 1"/32 mm bore HDPE pipe, PR-100 grade including fittings such as bends, socket, reducer, elbows, union etc in trenches complete all as specified and directed. 53 Open well submersible pump set multi stage 5 HP Single Phase 230 Volts 50 Hzhead-30mtr with all fittings and fixtures complete 54 Supply and connecting flat three core, PVC insulated industrial cable for submersible motor, 6 sqmm (Nominal area) with multi stranded copper conductor, 1100 volts grade connected from starter to submersible pump motor complete all as specified and directed. 55 Supply and Fix Submersible Pump DOL Starter 5/7.5 HP 56 DG Set 57 Supply, Install , testing and commissioning of silent engine DG set of minimum Capacity 60 KVA, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364, conforming to CPCB-IV approved norms complete with AMF panel, Relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS including PCC foundation etc. complete all as specified and as directed. 58 Schedule "A" Part - XIII (Outsourcing of Maintenance and operation) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only. Contractor has to quote his own rate. 59 Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 1st year after completion of defect liability period complete all as specified and directed. 60 Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 1st year after completion of defect liability period complete all as specified and directed. 61 Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 2nd year after completion of defect liability period complete all as specified and directed. 62 Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant during 2nd year after completion of defect liability period complete all as specified and directed. 63 Outsourcing for maintenance and operation of sewage treatment plant of capacity 900 KLD installed at INS Chilka domestic area for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 3rd year after completion of defect liability period complete all as specified and directed. 64 Outsourcing for maintenance and operation of sewage treatment plant of capacity 200 & 300 KLD installed at INS Chilka training area adjacent to each other for two shifts of 8 hours each per day from certified date of completion of work by employing one well experienced operator in the trade and one helper in each shift of 08 hours and including all consumable material required for operation of the plant for 3rd year after completion of defect liability period complete all as specified and directed. 65 Schedule "A" Part - XIII (Comprehensive MaintenanceThis schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.Note : Comprehensive mainteance include:(a) Repair/replacement of FAB media SBR/MBBR or any technology.(b) Repair/replacment of aur blower oil.(c) Repair/replacement of drives and other accessoriesof SCADA system for controlling operation of various motors.(d) Calibration of SCADA system including updation of softwares including replacement of necessary spares, checking relay contracts, replacement of relays, MCBs as per existing make and size, checking of alarm system to make it functional properly.(e) Repair/replacement of wornout/ unserviceable "V" belt for power transmission of air blowers.(f) Repair/replacement of defective MNX9 contactor AC3 rating 9 amps AC1 any rating with 1 NO + 1NC auxillary contracts.(g) Removing the old filtermedia and cleaning of internal walls of Dual media pressure filters at STP. 66 (h) Repair/replacement of any Pumps and other machineryused in STP and repair/replacement of U/S NP2 pipes or CI/DI pipes.(j) M&L for collecting the samples from raw sewage sump and treater water sump monthly from STP i.e. before and after treatment, sample handling, transporting to NABL approved accredited laboratory to carry out the analysis of the following as per latest IS methods:(i) BOD (Biological Oxigen Demand)(ii) COD (Chemical Oxigen Demand)(iii) TSS (Total Suspended Solids)(iv) Fecal Coliform(v) Turbidity(vi) PH(vii) Total Nitrogen(viii) Total Phosphorous(ix) Total Ammonia Nitrogen 67 Comprehensive maintenance of sewage treatment plantof capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed. 68 Comprehensive maintenance of sewage treatment plantof capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed. 69 Comprehensive maintenance of sewage treatment plantof capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 1st year after date of completion of defect liability period complete all as specified and directed. 70 Comprehensive maintenance of sewage treatment plantof capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed. 71 Comprehensive maintenance of sewage treatment plantof capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed. 72 Comprehensive maintenance of sewage treatment plantof capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 2nd year after date of completion of defect liability period complete all as specified and directed. 73 Comprehensive maintenance of sewage treatment plantof capacity 900 KLD installed at INS Chilka domestic area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed. 74 Comprehensive maintenance of sewage treatment plantof capacity 300 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed. 75 Comprehensive maintenance of sewage treatment plantof capacity 200 KLD installed at INS Chilka training area including SCADA system and all consumable materials/chemicals(such as sodium hypochlorite and other chemicals as required, oil, greese required for operation of the plant during 3rd year after date of completion of defect liability period complete all as specified and directed.
|