1. General Informationthe Subject Of The Order Is The Thermal Modernization Of The Façade Of Primary School No. 352 At Ul. Conrada 6 In Accordance With The Functional And Utility Program Developed Under The Name Modernization Of The Façade Of Primary School No. 352 At Ul. Conrada 6.2. Subject Of The Order:2.1. The Subject Of The Order Includes: 1) Preparation Of Complete Documentation Along With All Arrangements And Permits: - Preparation Of An Inventory To The Extent Necessary To Carry Out Designs And Modernization Of The Facade, - Preparation Of An Architectural Concept For The Colors Of The Facade And Terrace And Agreeing It With The Investor, - Preparation Of Multi-Disciplinary Documentation For The Works Covered By The Order (Facade, Flat Roof, Southern Terrace On The Ground Floor), - Preparation Of A Health And Safety Plan, - Preparation Of Technical Specifications For The Execution And Acceptance Of Construction Works Together With Bill Of Quantities And Investor Cost Estimates, - Obtaining All Necessary Arrangements, - Preparing An Energy Certificate For The Building After The Modernization, - Preparing As-Built Documentation, Participating In Acceptance Activities And In The Process Of Obtaining A Permit To Use The Facility; 2) Carrying Out Renovation Of The Facade: - Dismantling Strips Of Polystyrene Insulation At The Border Of Fire Zones And At The Staircases With A Minimum Width Of 2 M, - Dismantling The Silicate Brick Wall At The Western Wall At The Main Entrance, Which Is A Remnant Of The Old Fence, - Removing Climbing Greenery From The Walls Of The Building, - Insulating The Walls In Strips At The Border Of Fire Zones And At The Staircases At Least 2 M Wide With Non-Flammable Materials (E.G. Rock Wool For The Facade), - Insulating The Walls Of The School Buildings (Except For The Common Room And The Northern Gable Wall In The Gymnasium) With A Layer Of 6 Cm Thick Styrofoam Λ = 0.031 W/M·K, - Plastering On The Insulation And New Insulation, - Insulating The Ventilated Flat Roof Over The High Part Of The School (Building A) And Over The Ground Floor Part (Buildings B And C) With 20 Cm Thick Rock Wool Granules, - Insulating The Flat Roofs Of The Ground Floor Part Of Building A With Styrofoam (Or Polystyrene Plaster) With A Thickness 18-20 Cm, - Roof Covering With New Insulation, - New Sheet Metal Work On Ground Floor Roofs, On Cornices And Plinths, And Wherever Necessary In Connection With Building Insulation, Including The Replacement Of Gutters And Downpipes, - Replacement Of Window Joinery With New Energy-Saving Ones With A Transmittance Coefficient Of 0.90 W/M2·K Along With External Window Sills (Surface 1203 M2), Use Windows With Fire Resistance Ei60 At The Border Of Fire Zones, - Replacement Of Staircase Window Frames With An Aluminum Facade System With Fire Resistance Ei60, - Disassembly And Reassembly (After Renovation Of The Facade) Of All Installations Located On The Facade, I.E. Air Conditioning Elements, Cameras, Cabling,
Contact Information
Address
Miasto Stołeczne Warszawa - Dzielnica Bielany,Warszawa,01-882,Mazowieckie,Pl911 - Miasto Warszawa
Email
bielany.zamowienia@um.warszawa.pl
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 103911648
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.