Maintenance And Repair Of Summer Appliances Installed In Different Units Of Ins Garuda, ...


Contract Award Notice

TRR 8050289
Organization Military Engineer Services
Tender No 8926/E8
Funded By Self-Funded
Country India , Southern Asia
Contract Value 3 Million

Work Detail

Maintenance And Repair Of Summer Appliances Installed In Different Units Of Ins Garuda, Sfna, Nay ( K ) , Mo ( K ) And Snc ( O ) Mess At Naval Base Kochi.- 1 Material & Labour For General Servicing Of 1.5 / 2.0 Tr Capacity Window Type Ac After Taking Down From The Existing Position, Transporting To Workshop, Clean Internal Parts, Clean External Cover With Suitable Liquid / Solvent, Clean Filter / Washing With Water, Replace The Unserviceable Parts If Any Including Re-Fixing The Ac In Same / Other Location And Connecting, Commissioning Complete All As Directed. 2 All As Per Item No 1 Here In Above, But Outdoor Unit Of Split Type Air Conditioner 1.5 / 2.0 Ton. 3 All As Per Item No 1 Here In Above But Indoor Unit Of Split Type Air Conditioner 1.5 / 2.0 Ton. 4 All As Per Item No 1 Here In Above But Water Cooler Of Capacity 40 / 40, 40 / 80 Or 60 / 120. 5 All As Per Item No 1 Here In Above But Deep Freezer Of Capacity Upto 420 Litres 6 All As Per Item No 1 Here In Above But Refrigerator Of Capacity 165Ltrs To 310 Litres. 7 Material & Labour For General Servicing Of 1.0 / 1.5 / 2.0 Tr Capacity Window Type Ac After Taking Down From The Existing Position, Clean Internal Parts, Clean External Cover With Suitable Liquid / Solvent, Clean Filter / Washing With Water At Same Location, Replace The Unserviceable Parts If Any Including Re Fixing The Ac In Same / Other Location And Connecting, Commissioning Complete All As Directed. 8 All As Per Item No 7 Here In Above, But Outdoor Unit Of Split Type Air Conditioner 1.5 / 2.0 Ton. 9 All As Per Item No 7 Here In Above But Indoor Unit Of Split Type Air Conditioner 1.5 / 2.0 Ton. 10 All As Per Item No 7 Here In Above But Water Cooler Of Capacity 40 / 40, 40 / 80 Or 60 / 120. 11 Notes For Item No. 1 To 10Note 1:- The Quoted Rate Shall Be Deemed To Include The Cost Of Spare Parts Costing Upto Rs. 150 / -Note 2:- Replacing Parts Costing More Than Inr 150 / - Shall Be Measured And Paid Separately Under Respective Item. 12 Material & Labour For Leak Testing Of Window Type Air Conditioner Of Capacity 1.0 / 1.5 / 2.0 Tr Includingfilling Of Nitrogen Gas For Pressure Testing, Finding Leaks, Vacuuming The System, Necessary Brazing Work, Charging With Suitable Refrigerant Gas Of Required Quantity, Testing For Proper Functioning All As Specified And Directed. 13 All As Per Item No 11 Here In Above But Split Type Air Conditioner 1.5 / 2.0 Ton. 14 Supply & Fix In Replacement, Hermetically Sealed Compressor Unit Suitable For Window / Split Type Acs Of1.5 Ton Capacity In Exchange Of The Existing Unserviceable Sealed Compressor Unit Including Connecting Up Completeall As Specified & Directed. 15 All As Peritem No 13Here In Above But 2.0 Tr 16 All As Peritem No 13 Here In Above But Suitable For Water Cooler Of Capacity 40 / 40, 40 / 80 Litres 17 All As Peritem No 13Here In Above But Suitable For Water Cooler Of Capacity 60 / 120 Litres 18 All As Per Item No 13Here In Above But Suitable For Refrigerator Of Capacity 165 To 210 Litres 19 All As Peritem No 13Here In Above But Suitable For Refrigerator Of Capacity 210 To 310 Litres 20 All As Per Item No 13 Here Inabove But Suitable For Deep Freezer Of Capacity 420 Litres 21 Supply& Fix Copper Condensing Coil And Aluminium Fins Suitable For 1.5Tr Capacity Window Type Air Conditioner Including Necessary Brazing, Gas Charging, Leak Testing, Vacuuming Etc Including Taking Down Old Unserviceable Condensing Coil Complete All As Specified. 22 All As Per Item No 20 Here In Above But 2.0 Tr 23 All As Per Item No 20 Here In Above But Outdoor Unit Of Split Type Air Conditioner 1.5 / 2.0 Ton. 24 All As Peritem No 20 Here Inabove But Condenser Coil Suitable For Water Cooler Of Capacity 40 / 40, 40 / 80 25 All As Per Item No 20 Here Inabove But Condenser Coil Suitable For Water Cooler Of Capacity 60 / 120 26 All As Per Item No 20 Here In Above But Cooling Coil Of Indoor Unit Of Split Type Air Conditioner 1.5 / 2.0 Ton. 27 Supply& Fix Copper Condensing Coil And Metallic Fins Suitable For 165 To 210 Litres Capacity Refrigerator Including Necessary Brazing, Gas Charging, Leak Testing, Vacuuming Etc Including Taking Down Old Unserviceable Condensing Coil Complete All As Specified. 28 All As Per Item No. 26 Here In Above But Condenser Coil Suitable For Refrigerator Of Capacity 210 To 310 Litres. 29 Supply& Fix In Repairevaporator Coilmade Out Of Copper Tube Suitable For Refrigerator Of Capacity 165 To 210 Litres All As Per As Specified And As Directed 30 Supply& Fix Inrepair Evaporator Coil Made Out Of Copper Tube Suitable For Refrigerator Of Capacity 210 To 310 Ltrs As Per As Specified And As Directed 31 Supply& Fix In Repair Starting Capacitor120 / 150 Mfd Suitable For Window / Split Ac All As Specified And As Directed 32 Supply& Fix In Repair Running Capacitor 45 Mfd Suitable For Window / Split Type Ac All As Specified. 33 All As Per Item No 31Here In Above But 36 Mfd 34 All As Per Item No 31Here Inabove But 10 Mfd 35 All As Peritem No 31Here In Above But 8 Mfd 36 Supply & Fix In Repair Capacitor 6 Mfd, 240Vsuitable For Fan Motor Of Window / Split Type Ac All As Specified And As Directed. 37 All As Per Item No 35 Here In Above But 4 Mfd, 240V 38 All As Peritem No 35 Here In Above But 2 / 2.5Mfd, 240V 39 All As Per Item No 35 Here In Above But 1.5Mfd, 240V 40 Supply & Fix In Repair Fan Motor 1 / 5 Hp, 240V Long Shaftsuitable For Window Type Ac Of Any Capacity, Make Or Model Complete All As Specified And Directed. 41 Supply & Fix In Repair Fan Motor 1 / 5 Hp 240V Suitable For Outdoor Unit Of Split Type Ac Of Any Capacity, Make Or Model Complete All As Specified And Directed. 42 Supply & Fix In Repair Fan Motor 1 / 35 Hp 240V With Leaf Suitable For Water Cooler Complete All As Specified And Directed. 43 Supply & Fix In Repair Fan Motor 240V Suitable For Outdoor Unit Of Inverter Type Split Ac Of Any Capacity Make Or Model Complete All As Specified And As Directed. 44 Supply & Fix In Repair Fan Motor 240 V Suitable For Indoor Unit Of Inverter Type Split Ac Of Any Capacity, Make Or Model Complete All As Specified And As Directed. 45 Supply & Fix In Repair Fan Blade Suitable For Window Type Ac Of Any Capacity Make Or Model Complete All As Specified And As Directed. 46 Supply & Fix In Repair Fan Blade Suitable For Outdoor Unit Of Split Type Ac Of Any Capacity, Make Or Model Complete All As Specified And As Directed. 47 Supply & Fix In Repair Thermostat Switch Suitable For Window Type Ac Of Any Capacity Make Or Model Complete All As Specified And As Directed. 48 Supply & Fix In Repair Starting Relay Pin Type Suitable For Window / Split Type Ac Of Any Capacity Make Or Model Complete All As Specified And As Directed. 49 Supply & Fix In Repair Pre Filter Washable Type Suitable For Window Type Ac Of Any Capacity, Make Or Model Complete All As Specified And As Directed. 50 Supply & Fix In Repair Pre Filter Washable Type Fibre Filter Suitable For Split Type Ac Of Any Capacity Make Or Model All As Specified As Directed. 51 Supply & Fix In Repair Pvc Float Valve Assembly 15Mm Bore Suitable For Water Cooler All As Specified As Directed. 52 Supply & Fix In Repair 15 Mm Bore Lift Cock Tap Suitable For Water Cooler All As Specified As Directed. 53 Supply & Fix In Repair 15 Mm Pvc Connection 1 Meter Long Suitable For Water Cooler All As Specified As Directed. 54 Supply & Fix In Repair 1 1 / 4 " Flexible Hose Suitable For Water Cooler Drain All As Specified As Directed. 55 Removing Old Perished Insulations And Supply& Fix Nitrile Rubber Insulation Of Size 5 / 8" For Suction And Liquid Refrigerant Line Suitable For Split Type Ac All As Specified And As Directed. 56 Supply& Fix In Repair Copper Tube 3 / 8" With “O” Nitrile Rubber Insulation Complete All As Specified And As Directed. 57 Supply& Fix In Repair Copper Tube 5 / 8" With “O” Nitrile Rubber Insulation Complete All As Specified And As Directed. 58 Supply& Fix In Repair Copper Tube 3 / 4" With “O” Nitrile Rubber Insulation Complete All As Specified And As Directed. 59 Supply& Fix In Repair Copper Tube 1 / 4" With “O” Nitrile Rubber Insulation Complete All As Specified And As Directed. 60 Supply& Fix In Repair Copper Tube 1 / 2" With “O” Nitrile Rubber Insulation Complete All As Specified And As Directed. 61 Supply And Replace Prime Controlremote Board Andtemperature Digital Display Sensor Suitable For Split Type / Window Ac Of Any Capacity, Make Or Model All As Per Site Requirement. 62 Supply And Replace Prime Controlremote Board Andtemperature Digital Display Sensor Suitable For 3 Phase Cassette Tower Ac Of Any Capacity, Make Or Model All As Per Site Requirement. 63 Supply And Replace Factory Made Ms Bracket Or Stand Duly Painted Suitable For Outdoor Unit Of Split Ac Including Necessary Pcc Work, Making Surface Matching With Existing Etc Complete All As Specified. 64 Supply And Fill Refrigerant Gas-R-22. 65 Supply And Fill Refrigerant Gas-410A ( Penta & Di Fluoroethane ) . 66 Supply And Fill Refrigerant Gas R- 32. 67 Material & Labour In Repair To Voltage Stabilizer 5 Kva By Rewinding The Main Stabilizing Unit And Replacing Pcb, Sensing Unit, Power Relay, Connector Piece And Testing On Completion All As Specified And Asdirected 68 All As Peritem No 66 Here In Above But Of 4Kva 69 Supply& Fix In Repair 3 Core Multistranded Copper Conductor Pvc Insulated Sheathed Flexible Cable Of Size 2.5 Sqmm Complete All As Specified And As Directed 70 All As Per Item No 68 Here In Above But 4.0Sqmm 71 Material & Labour For Sealed Compressor Unit Suitable For 2.5 / 3 / 4 Tr Capacity 3 Phase Tower / Caette Type Ac Including First Filling Of Refrigerant Gas, Compressor Oil Etc. Testing And Commissioning, Including Taking Down Of Old Unserviceable One Complete All As Specified And Directed 72 Material & Labour For Servicing Of Condenser Coil Of Tower Split Ac Upto 5 Tr Capacity, Cleaning / Pressure Washing Of Choked Condenser Fins, Tubes Etc. With Water Soluble Material Including Leak Testing Complete All As Specified And Asdirected 73 Supply& Fix In Repair Fan Motor Suitable For Outdoor Unit Oftower / Cassette Type Ac Of Any Capacity Make Or Model All As Specified And Directed. 74 Supply& Fix In Repairindustrial Type Metallic 3 Pin Top 20 Amps 240V Complete All As Specified And Directed 75 Supply& Fix In Repair 15 Amps 240 V Plug Top Heavy Duty Complete All As Specified And Directed 76 Material & Labour For Sub Main Wiring On Wall / Ceilingwith 2 Runs Of 4 Sqmm Single Core Pvc Insulated Un Sheathed Multi Stranded Copper Cunductor Fr Cable 1100V Grade Drawn Through Andincluding Pvc Conduit Pipe Of Medium Grade Not Less Than 20Mm Dia Including Pvc Conduit Specials And 1 Run Of 4 Sqmm Cable Single Core 1100 V Grade Multi Stranded Copper Conductor Fr Cable As Earth Continuity Conductor And Connecting With Suitable Size Thimble Including Taking Down Of Old One Complete All As Specifed And As Directednote: Two Runs Of Sub Main Wire, One Run Of Earth Wire And Pvc Conduit With Accessories Shall Be Measured As One Unit. 77 Supply & Fix In Repair Sheet Metal Enclosure Single Pole With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb 20 Amp, 240 V Complete All As Specified And Directed. 78 Supply & Fix In Replacement Of Mcb Sp 6 To32 Amps "C" Series 240V, Complete All As Specified And Directed. 79 Material & Labour For Spray Painting Single Coat Anti Corrosive Enamel Paint To Cover Of Window Ac Of Any Capacity Complete All As Specified And Directed. 80 Material & Labour For Spray Painting Single Coat Anti Corrosive Enamel Paint To Outer Unit Of Split Ac 1 / 1.5 / 2 Tr Capacity Complete All As Specified And Directed. 81 Material & Labour For Spray Painting Single Coat Anti Corrosive Enamel Paint To Water Cooler Of Any Capacity Complete All As Specified And Directed. 82 Material & Labour For Spray Painting Single Coat Anti Corrosive Enamel Paint To Cover Of Refegrotor Of Any Capacity Complete All As Specified And Directed. 83 Supply And Fix Of Stop Valves Of 15Mm, Chromium Plate, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Cpvc Pipe, Unions And Fixed All As Directed By Engineer-In-Charge. 84 Material & Labour For Disconnecting The Unserviceable Stabilizer Of Any Capacity 230 Volts, Any Make From Site And Servicing Complete And Refixing Back With Necessary Nuts / Bolts Fixed On Walls And Connecting Up With A / C"Sdrilling As Per Site Requirement And All As Directed By Engineer-In-Charge. 85 Material & Labour For Dismantling, Taking Down After Disconnection Split A / C Of Capacity 1.5 / 2.0Tr From Existing Location Including Indoor / Outdoor Units Alongwith Its Pipes, Connecting Cables, Clamps / Stands, Water Drain Pipes Etc Including Making Good The Surfaces To Match With Existing Finishes In All Respects And Re-Fixing At New Location As Directed With All Accessories Such As Clamps, Pipes, Stand For Outdoor Unit Including Top Up Of Refrigerant Gas If Required And Making Satisfactory Working Of A / C Unit In All Respect Complete All As Directed And Specified By Engineer-In-Charge 86 Supply & Fix In Repair Blower Motor & Blower For Indoor Unit Of Any Capacity Suitable Make Or Model Complete All As Specified And Directed. 87 Supply & Fix In Repair Drain Motor Of Cassette Type Ac Of Any Capacity. 88 Material & Labour For Servicing Of Condenser Coil Of Cassette Type Ac Upto 5 Tr Capacity, Cleaning / Pressure Washing Of Choked Condenser Fins, Tubes Etc, With Water Soluble Material Including Leak Testing Complete All As Specified And As Directed. 89 Material And Labour For Attending Day To Day Complaints Pertains To Various Capacity Of Cooling Appliances As And When Required By Refrigerator Mechanic And Helper With Necessary Tools And Plants For Checking The Equipment At Existing Location, Find Out The Faults To The Equipments, Complete And Rectificationof Minor Problems ( Compressor Control Panel Resetting With Electrical Components Like Replacement Of Lugs / Pin, Mcb Resetting, Electrical Wiring Connections Gas Top Up ( Gas Shall Be Measured And Paid Separately Under Relevant Item ) ) , To Make The Ac Functional In All Respect All As Directed By The Engineer -In Charge.Notes: 1. Works Covered Under Item No.7 To 10, 84 To 85 Of Boq Only Shall Be Executed At Various Locations Inside The Naval Base. 2. Complaints / Service Schedule List Shall Be Collected From Concerned Je / Engineer-In Charge And Report Back On Daily Basis. 3. The Serial Item Nos Of Boq Other Than 7 To 10, 84 & 85 Shall Be Outside The Scope Of This Item. 4. A Penalty Of Rs.250 / - Per Day Will Be Levied In Case Breakdown Of Equipment More Than 48 Hours From The Time Of Complaint Registration Due To Non Attending. 90 Amount Of Credit Schedule Shall Be Deducted To Arrive The Contract Sum.

Key Dates

Contract Date 13 Jul 2022

Contact Information

Company Name
Awarded Bids List
S.No Bid Number Bidder Name Awarded Currency Awarded Value
1 2375384 AR Traders INR 3296982.50
Contract Value 3 Million
Contract Date 13 Jul 2022

Complete details of the selected Tender
Organisation Name : Vijaya Bank
Organisation Type : Public Sector Banks Ministry : Ministry of Finance
Tender Ref. No : DIT/DELHIARMB/07052016/1
Tender Title : E-Auction Sale Notice for the properties of M/s Guru Kripa Iron Trading Pvt Ltd, mortgaged to Vijaya Bank and taken possession under the provisions of SARFAESI Act 2002.
Product Category : Land/Building
Sub Category :
Tender Value (INR if not mentioned):
Rs 1,62,00,000/-
EMD :
1620000
Document Cost :
0
Tender Type : Auction
Location : Delhi
First   
Announcement Date :
5-July-2016  
Publication Date on Portal: 5-July-2016 At : 8:03:09 PM  
Last Date of Document Collection :  
8-August-2016 Up To : 5:00 PM  
Last date for  
Submission :
8-August-2016 Up To : 5:00 PM  
Opening Date : 10-August-2016 At : 11:00 AM  
Work Description :
Pre-Qualification :
PreBid Meet Date : --
Tender Document : View Document *
Bid Document : Document Not available
Tech. Document : Document Not available
Sector : Banking, Finance & Insurance
State : Karnataka
 
For further Information Contact:
Name : Santhosh Aili
E-Mail : cbsprog11@vijayabank.co.in
Phone Office : 08025584066
Fax : 08025582747
Address :
City : Bangalore

  download Adobe® Reader®