E-Tender For Empanelment Of Nabl Laboratory For Testing Of Drugs, Kit, Chemicals And Reag...


Contract Award Notice

TRR 7115748
Organization Health And Family Welfare Department
Tender No WBHF/CMS/ HST/4T-44-2021/NABL/2021/153
Funded By Self-Funded
Country India , Southern Asia
Contract Value 1

Work Detail

E-Tender For Empanelment Of Nabl Laboratory For Testing Of Drugs, Kit, Chemicals And Reagents And Consumables For Two Years From The Date Of A.O.C. ( 2021-2023 ) By The Deputy Director Of Health Services ( E S ) , Central Medical Stores. , Total Psa Elisa Kit , Treponemal-Specific Rapid ( Point-Of-Care ) Diagnostic Test For Syphilis ( Poc Test Kit ) Technical Specification : O The Assay Should Have Solid Phase Coated With Synthetic Or Recombinant Type Of Treponema Pallidum Antigens. O The Assay May Be Based On Any Of The Rapid Test Principles: O ( Immunoconcentration / Dot Blot Immunoassay ( Vertical Flow ) , Dip Stick And Comb Assay. O The Assay Should Quantitatively Detect Total Anti-Treponemal Antibody ( Igg And Igm ) In Whole Blood, Serum Or Plasma For Serological Diagnosis Of Syphilis In All Stages Of Infection. O The Assay Should Have An In-Built Positive And Negative Control For Testing The Validity Of The Test Kits. O The Assay Should Have Reactive And Non-Reactive Controls With Each Kit In Adequate Volume ( Minimum 10% Of Pack Size ) . O The Kit Should Have 5 / 6Th Of The Shelf Life Or 12 Months Before Expiry ( Whichever Is More ) At The Item Of Receipt By The Consignee. O Adequate Literature Detailing The Principle, Components, Methodologies, Validity Criteria, Bio-Safety , Performance Characteristics, Storage Conditions, Limitation Of Assay, Manufacture And Expiry Dates And Methods Of Disposal Should Be Provided With Each Kit. O The Imported Rapid Kit Should Have Approval Of The Statutory Authority In Its Country Of Origin. The Imported Kits Should Have Been Registered And Licensed In India By The Central Drugs Standard Control Organisation ( Cdsco ) . O In Case Of Indigenous Manufacturers They Should Have A Valid Licence Issued By The Competent Authority Defined Under Drugs And Cosmetics Act, 1940, After Appropriate Evaluation By The Centres Approved By The Cdsco. O The Assay Should Have Sensitivity Of 90% Or More And Specificity Of 95% Or More And The Same Should Be Supported By Statements In Kit Insert And Certificate From National Institute Of Biological Sciences. O The Assay Should Be Calibrated By Who Reference Serum And The Same Should Be Supported By Statements In Kit Insert And Certificate From The Manufacturer. O The Manufacturer Should Ensure The Following: >> The Test Should Be Packed Such That There Is A Provision To Conduct Single Test At A Time. >> The Pack Size Of Test Kits Should Be In 50 ( For Peripheral Health Levels ) And 100 Tests Per Kit ( For Secondary And Tertiary Health Care Level ) But Not More Than 100 Tests Per Kit. O The Manufacturer / Authorized Agent Should Ensure Maintenance Of Cold Chain During Storage And Transport Of Kits At 2°C - 8°C. O Total Procedure Time Should Not Be More Than 30 Minutes. O The Test Kit Should Be Supplied With Micro-Pipette Of 1 Micro Litre Volume O The Test Kit Should Be Supplied With Sterilized Disposable Lancet One For Each Test O Alcohol Soaked Swab Should Be Supplied With One For Each Test. , Tri Sodium Citrate , Triglyceride Test Kit , Trimethoprim Antibiotic Disc , Tsh - Elisa , Tsi Agar , Typhoid Igm Test Kit , Urea - ( Gldh ) Reagent Kit , Urea - ( Berthelot ) Reagent Kit , Urea Agar Base , Urea Solution Sterile 40% , Uric Acid Test Kit , Uristix ( 10 Parameters ) , Vancomycin Antibiotic Disc , Vdrl Kit - Latex Kit , Vitamin D Elisa Kit , White Soft Paraffin I.P. , Whole Blood Finger-Prick Hiv Test Kit. Technical Specifications 1. The Indigenous Hiv Antibody Rapid Test Kits Should Have A Valid License Issued By The Competent Authority Defined Under Drugs & Cosmetics Act. 1940 After Appropriate Evaluation By The Centres Approved By Dcg ( I ) . The Imported Rapid Test Kits Should Have The Approval Of The Statutory Authority In The Country Of Origin / Manufacture And Should Satisfy The Requirements Of Drugs And Cosmetics Act In India. The Imported Kits Should Also Get Evaluated In Our Country 2. The Assay Should Be Able To Detect Antibodies Of Hiv-I And Hiv-2 And All The Subtypes By Detection Of Antibodies By The Agglutination, Enzyme Immune Assay Or Any Other Principal. 3. The Assay Should Have Sensitivity Of 99.5% Or More And Specificity Of 98% Or More As Per Data From An Identified National Reference Laboratory. 4. The Assay Should Have Solid Phase / Particles Coated With Synthetic And / Or Recombination Or Both Types Of Antigens Of Hiv1 & Hiv2. 5. Total Procedure Time Should Not Be More Than 30 Minutes. 6. The Manufactures Should Ensure That A. The Test Kit Should Be Packed Such That There Is A Provision To Conduct Single Test At A Time. B. The Assay Components Should Include Hiv Positive And Negative Serum Controls Sufficient For Conducting 20% Of The Tests ( 10% Negative & 10% Positive Controls ) ; And C. The Pack Size Of Hiv Rapid Test Kits Should Not Be More Than 50 Tests Per Kit. , Widal Antigen Test Kit , Xld Agar , Xylene , Ppd Tuberculin 5Tu / 0.1 Ml - 5Ml , Oxalic Acid , Sodium Hypochloride 5% Solution , Absorbable Gelatine Sponge 20Cm X 7Cm X .05Cm , Absorbable Gelatine Sponge 07Cm X 5Cm X 1Cm , Absorbable Gelatine Sponge 7Cm X 5Cm X 0.1Cm , Absorbable Gelatine Sponge Anal 0.3Cm X 8Cm , Access Guidewire - Nitinol Core Wire. Straight Tip With Hydrophilic Coating. Working Length : 450 Cm, Outer Dia : 0.035" , Adhesive ( Copolymer ) Based Silk Tape, Non-Elastic Tape With Strong Tensile Strength, 1.25 Cm ( Minimum. ) X 9 M ( Minimum ) . , Adhesive ( Copolymer ) Based Silk Tape, Non-Elastic Tape With Strong Tensile Strength, 2.50 Cm ( Minimum ) X 9M ( Minimum ) . , Adhesive ( Copolymer ) Based Silk Tape, Non-Elastic Tape With Strong Tensile Strength, 5.00 Cm ( Minimum ) X 9M ( Minimum ) . , Adhesive ( Copolymer ) Based Silk Tape, Non-Elastic Tape With Strong Tensile Strength, 7.50 Cm ( Minimum ) X 9M ( Minimum ) . , Adhesive Elastic Bandage ( 10Cm X 4 Mtr. ) , Adhesive Elastic Bandage ( 10Cm X 6 Mtr. ) , Adhesive Plaster Plain 10 Cm X 10 M , Adhesive Plaster Plain 5 Cm X 10 M , Adhesive Plaster Plain 7.5 Cm X 10 M , Adhesive, Paper Adhesive Plaster 2.50 Cm ( Minimum ) X 9M ( Minimum ) , Breathable And Comfortable, Non Woven Adhesive Tape , Adhesive, Paper Adhesive Plaster 1.25 Cm ( Minimum. ) X 9 M ( Minimum ) , Breathable And Comfortable, Non Woven Adhesive Tape , Adhesive, Paper Adhesive Plaster 5.00 Cm ( Minimum ) X 9M ( Minimum ) , Breathable And Comfortable, Non Woven Adhesive Tape , Adhesive, Paper Adhesive Plaster 7.50 Cm ( Minimum ) X 9M ( Minimum ) , Breathable And Comfortable, Non Woven Adhesive Tape , Adhesive, Sterilized Umbilical Cotton Tape Width 3 Mm , Length 75 Cm , Adhesive, Transparent Film Dressing With Window Frame Delivery Style, Waterproof, Sterile, Bacterial And Viral Barrier, High Adhesive But Skin Friendly With Easy Stretch And Release Technique For Removal ( 14Cm - 16 Cm X 19Cm - 21Cm ) , Adhesive, Transparent Film Dressing With Window Frame Delivery Style, Waterproof, Sterile, Bacterial And Viral Barrier, High Adhesive But Skin Friendly With Easy Stretch And Release Technique For Removal ( 4.5Cm - 5.5Cm X 5Cm - 6Cm ) , Adhesive, Transparent Iv Dressing With Window Frame Delivery Style, Waterproof, Sterile, Bacterial And Viral Barrier, High Adhesive But Skin Friendly With Easy Stretch And Release Technique For Removal ( 9Cm - 11Cm X 11Cm - 13Cm ) , Adhesive, Transparent Iv Dressing With Window Frame Delivery Style, Waterproof, Sterile, Bacterial And Viral Barrier, High Adhesive But Skin Friendly With Easy Stretch And Release Technique For Removal ( 5.5Cm - 6.5Cm X6.5Cm - 7.5Cm ) , Adhesive, Transparent Polyethylene Surgical Tape : Perforated, Breathable, Polyethylene, Transparent Backing With Straight And Easy Bi-Directional Tear, Coated With Pressure Sensitive, Hypoallergenic Acrylate With High Adhesive Strength Tape ( 0.75 Cm - 1.50Cm X 8.50 Cm - 10Cm ) , Adhesive, Transparent Polyethylene Surgical Tape : Perforated, Breathable, Polyethylene, Transparent Backing With Straight And Easy Bi-Directional Tear, Coated With Pressure Sensitive, Hypoallergenic Acrylate With High Adhesive Strength Tape 2.4Cm- 2.6Cm X 8.5Cm - 10Cm , Adhesive, Transparent Polyethylene Surgical Tape : Perforated, Breathable, Polyethylene, Transparent Backing With Straight And Easy Bi-Directional Tear, Coated With Pressure Sensitive, Hypoallergenic Acrylate With High Adhesive Strength Tape 4.5Cm - 5.5 Cm X 8.5Cm - 10Cm , Adhesive, Transparent Polyethylene Surgical Tape : Perforated, Breathable, Polyethylene, Transparent Backing With Straight And Easy Bi-Directional Tear, Coated With Pressure Sensitive, Hypoallergenic Acrylate With High Adhesive Strength Tape 6.5Cm - 8 Cm X 8.5Cm - 10Cm , Adhesive, Transparent Sterile Water Proof, Bacterial And Viral Barrier Polyurethane Film With Absorbent Non-Adherent Pad And Hypoallergenic Acrylic Adhesive’ With Window Frame Delivery Style, ( 5.5Cm - 6.5 Cm X 9Cm - 11Cm ) , Adhesive, Transparent Sterile Water Proof, Bacterial And Viral Barrier Polyurethane Film With Absorbent Non-Adherent Pad And Hypoallergenic Acrylic Adhesive’ With Window Frame Delivery Style, ( 8Cm - 10 Cm X 9Cm - 11Cm ) , Adhesive, Transparent Sterile Water Proof, Bacterial And Viral Barrier Polyurethane Film With Absorbent Non-Adherent Pad And Hypoallergenic Acrylic Adhesive’ With Window Frame Delivery Style, ( 8Cm - 10 Cm X14cm - 16Cm ) , Adhesive, Transparent Sterile Water Proof, Bacterial And Viral Barrier Polyurethane Film With Absorbent Non-Adherent Pad And Hypoallergenic Acrylic Adhesive’ With Window Frame Delivery Style, ( 8Cm - 10 Cm X 18Cm - 22 Cm ) , Resuscitation Bags - 240Ml, 500Ml & 750Ml Quantity Technical Specification: 1. Self Inflating Bag 2. Provided With Closed Ended Reservoir With Two Valves 3. Face Masks: 3 Sizes: 00, 01 & 02: 2 Of Each Size Per Bag Making 2 Set 4. Its Fitted With Safety Valve Set At 40 Cm H2o, Has An Outlet For Pressure Monitoring 5. Bag Should Be Made Of Sterilizable Synthetic Material Like Silicone 6. Patient Valve Should Be Well Sealed, Have Minimum Dead Space And No Forward Or Backward Leaks 7. The Bag Should Have An Oxygen Inlet Which Fits Into The Standard Oxygen Tubing Both From A Cylinder And Central Supply. 8. Reusable Face Masks Should Be Transparent, Fit The Patient Outlet Of The Bag Easily And Have Minimum Dead Space. 9. The System Should With Stand Washing Scrubbing And Autoclaving Procedures, Chemical Sterilization. , Ambu Bag ( Resuscitation Bags ) - 500Ml Quantity Technical Specification: 1. Self Inflating Bag 2. Provided With Closed Ended Reservoir With Two Valves 3.Face Masks: 3 Sizes: 00, 01 & 02: 2 Of Each Size Per Bag Making 2 Set 4.Its Fitted With Safety Valve Set At 40 Cm H2o, Has An Outlet For Pressure Monitoring 5.Bag Should Be Made Of Sterilizable Synthetic Material Like Silicone 6.Patient Valve Should Be Well Sealed, Have Minimum Dead Space And No Forward Or Backward Leaks 7.The Bag Should Have An Oxygen Inlet Which Fits Into The Standard Oxygen Tubing Both From A Cylinder And Central Supply. 8.Reusable Face Masks Should Be Transparent, Fit The Patient Outlet Of The Bag Easily And Have Minimum Dead Space. 9.The System Should With Stand Washing Scrubbing And Autoclaving Procedures, Chemical Sterilization. , Amplatzer Extra Stiff Type Guide Wire. • Length Should Be 180 Cm & 260Cm. • Dia Should Be 0.038” & 0.035”. , Antibiotic Tulle Dressing Impregnated With White Paraffin Wax 10 X 10 Cm , Arterial Filter ( Adult ) Ce / Usfda Certified. , Arterial Filter ( Pediatric ) : Polycarbonate, Polyester Screen Type, Filterpore Size 32Um, Vent Port - Female Luer Port, Priming Volume - 40Ml, Max. Blood Flow Rate 2.5L Per Min, Ce / Usfda Certified. , Arterial Lines : Polyethylene / Polyeurathene Arterial Lines ( Singlelumen 18G - Length-15Cm / 10Cm / 8Cm / 6Cm / 4Cm ) With Seldinger Technique , Arterial Lines : Polyethylene / Polyeurathene Arterial Lines ( Singlelumen 20G - Length-15Cm / 10Cm / 8Cm / 6Cm / 4Cm ) With Seldinger Technique , Arterial Lines : Polyethylene / Polyeurathene Arterial Lines ( Singlelumen 22G - Length-15Cm / 10Cm / 8Cm / 6Cm / 4Cm ) With Seldinger Technique , Bacteria Viral Filters For Ventilator Adult Size , Bacteria Viral Filters For Ventilator Paediatric Size , Bag, Biomedical Waste Carrying Bag Colour – Black Size – Should Be Match With 30 Letres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Black Size – Should Be Match With 50 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Yellow Size – Should Be Match With 30 Letres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Black Size – Should Be Match With 100 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Yellow Size – Should Be Match With 50 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Yellow Size – Should Be Match With 100 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Red Size – Should Be Match With 30 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Red Size – Should Be Match With 50 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Biomedical Waste Carrying Bag Colour – Red Size – Should Be Match With 100 Litres Bin Specifications – • Virgin Plastic Non Chlorinated Polymer Made. • Specially Designed Biodegradable Waste Collection Bags. • With Easy To Hold. • With Plastic Cable Break Away Lock / Collar Tie / Knot Arrangement. • All Bags Are To Be Customized With Bio-Hazard Sign And Pre-Printed As Per Wbpcb Norms. • Thickness Of The Plastic Should Be Minimum 55 Microns. • Should Be Leak Proof. • Puncture Resistant. • Should Have Uniform Density Without Defects Like Tears, Holes Or Weak Areas. • Bis 9738:2003 Certified. , Bag, Colostomy / Ilestomy One-Pc Transparent Bag With Oval Shaped Spiral Adhesive Including Flex Zones, Hide Away Outlet And Integrated Charcoal Filter-- Custom Cut 12-75 Mm , Bag, Disposable, Thoracic Drainage System , Bain Circuit ( Adult ) , Manually Adjustable Non Metallic Apl Valve For Mri Compatibility , Bain Circuit ( Paediatric ) , Manually Adjustable Non Metallic Apl Valve For Mri Compatibility , Bandage, Crepe Bandage B.P. 10 Cmx4 Meter , Bandage, Crepe Bandage B.P. 15 Cm X 4 Meter , Battery Operated Sternal Saw Sysytem Specification :- • All Attachment Should Be Made Of Stainless Steel. • Should Be Fully Autoclavable. Reciprocating Saw Hand Piece: • Should Have Sternum Guard • Should Have Minimum 1500 Cm • Weight Of Hand Piece With Battery Should Be Not More Than 3.5 Ibs • Saw Noise Level Should Not More Than 93 Dp • Should Be Autoclavable Except Battery • Should Be Supplied With 2 Blades Of Sternotomy Surgery-Effective Length 34-43 Mm, Width-1.3Mm-9 Mm. Saggital Saw Handpiece ( Redo Sternum Saw ) • The Oscillating Saw Head Should Be 360 Deg Rotatable In Eight Steps. • Power – More Than 220 W • Cpm - 0-15, 000 • Amplitude - 4°47 • Weight – Less Than 1650 Gm Including Battery & Lid • Should Be Supplied With 2 Blades For Tjr Surgery – Effective Length 85-95Mm, Width 19-25Mm, Thickness 0.89 – 1.37Mm • Should Be Supplied With 2 Blades For General Traumatology – Effective Length 35 – 65 Mm, Width 10-50Mm, Thickness 0.5 – 0.9Mm Battery • It Should Be Nimh / Nicd / Lithium Ion Battery. • The Battery Should Be Of More Than 1.7 Ah. Lid • Should Have Quick Locking Facility. Sterile Funnel • Should Be Made Of Peek. Battery Removal Device • For Intra Operative Removal Of Battery. • Should Be Made Of Peek. Battery Charger • The Battery Charger Should Have 4 Charging Station. With Electronically Controlled Charging Process And Automatic Switch To Maintain The Charge. • It Automatically Should Indicate When The Battery Needs To Be Replaced. Sterilization Basket • The System Should Be Supplied With Perforated Basket Made Of Stainless Steel. • It Should Proper Holding Slots For Handpiece & Attachment. Sterilization Container • Should Be Made Of Aluminum. • The Container Lid Should Have Reusable Ptfe Permanent Bacteria Filter. The Ptfe Bacteria Filter Last Up To 1000 Sterilization Cycles. , Beaker Glass, Graduated, 1000Ml, High-Quality Borosilicate Glass That Can Be Heated Directly In An Open Flame , Beaker Glass, Graduated, 250Ml, High-Quality Borosilicate Glass That Can Be Heated Directly In An Open Flame , Beaker Glass, Graduated, 500Ml, High-Quality Borosilicate Glass That Can Be Heated Directly In An Open Flame , Beaker Glass, Graduated, 750Ml, High-Quality Borosilicate Glass That Can Be Heated Directly In An Open Flame , Biopsy Needle With Gun, Disposable, Size 14G / 16G, Length - 10 / 16 Cm , Biopsy Needle With Gun, Disposable, Size 18G Length - 10Cm , Biopsy Needle With Gun, Disposable, Size 18G Length - 16Cm , Biopsy Needle With Gun, Disposable, Size 18G Length - 20Cm , Biopsy Needle With Gun, Disposable, Size 18G Length - 25Cm , Biopsy Needle With Gun, Disposable, Size 20G, Length - 10 / 16 / 20 Cm , Blades, Stainless Steel Safety Razor Blades , Bleached Bandage Cloth , Bleached Gauze Cloth , Blood Pressure Equipment, Anaroid Type ( Sphygmomanometer, Aneroid Type ) , Blood Transfusion Set, Sterile, Disposable • Medical Grade Non Toxic And Soft Pvc Tubing • Clear, Transparent, Flexible Molded Drip Chambers With Fix Fluid Filters And Sharp Pointed Spikes For Easy Piercing • Efficient Roller Control For Better Flow Control • Molded “Bulb Type” Injection Site For Extra Medication • Approximately 20 Drops, 1 Ml Dw • Sterilization By Eto , Bone Cement 40 Gm Pack ( Regular Viscosity & Low Viscosity ) With Gentamycin : Methyl Methacrylate / Methyl Acrylate Copolymer Blend Sterilised Using Ethylene Oxide Gas. . , Bone Wax, Sterilised , Bulldog Clamp ( Micro ) , Curved 3.5 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Curved 4 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Curved 6 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Curved 7.5 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Curved 9 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Straight 3.5 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Straight 4 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Straight 6 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Straight 7.5 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Bulldog Clamp ( Micro ) , Straight 9 Cm Lengths, Single Use Bulldog Clamps Are A Lightweight Radiopaque Plastic Construction. Colour Coded According To Clamp Size And Pressure. Atraumatic Jaw Designs. Parallel Clamp Designed For Maximum Occlusion And Atraumatic Pressure. Latex-Safe. , Cannula, Aortic Arch Cannula - Neonatal : Straight Tip, Soft Flexible Bodyenables Easy Poioning Yet Resist Kinking, 8Fr ( 2.7 Mm ) , 1 / 4 Connector, Ce / Usfda Certified. , Cannula, Aortic Arch Cannula - Paediatric : Straight Tip, Soft Flexible Bodyenables Easy Poioning Yet Resist Kinking, 16Fr, 1 / 4 Connector, Ce / Usfda Certified. , Cannula, Aortic Arch Cannula With Metal Legs, Ce / Usfda Certified. , Cannula, Arterial Cannula With Flow Switch. Size : 20G / 1.10Mm X 45Mm, 49Ml / Min. Used Only Radial Artery, Ce / Usfda Certified. , Cannula, Cardiopledigia Cannula ( Neontal ) : Radiopaque Tips Attached To Clear Bodies , Left Heart Venting Long Tip And Standard Introducer. Size : 14 Ga ( 7 Fr. ) , Ce / Usfda Certified. , Cannula, Cardiopledigia Cannula ( Paediatric ) : Radiopaque Tips Attached To Clear Bodies With Separate Vent Lines , Include Aortic Root Pressure Monitoring And Left Heart Venting. Size : 16 Ga ( 5 Fr. ) , Ce / Usfda Certified. , Cannula, Disposable Thoracic Drainage With Bag , Cannula, Femoral Arterial Cannula: Kink Resistance Thin Wall, Radio Opaque Bodies With Multiple Side Holes. Depth Markings Permit Precise Positioning Of The Cannula With A Tapered Tip Dilator Which Facilitates Insertion Over 0.038 In. ( 0.1 Cm ) Guide Wire. Size : Assorted, 7 In. ( 17.8 Cm ) Overall Length, Ce / Usfda Certified. , Cannula, Femoral Venous Cannula : Kink Resistance Thin Wall, Radio Opaque Bodies With Multiple Side Holes. Depth Markings Permit Precise Positioning Of The Cannula With A Tapered Tip Dilator Which Facilitates Insertion Over 0.038 In. ( 0.1 Cm ) Guide Wire. Size : Assorted, 21 In. ( 53.3 Cm ) Overall Length 25.5 In. ( 64.8 Cm ) Over All Length. , Cannula, Karman Type Flexible Plastic Cannula And With Built-In Adaptor - 4, 5, 6, 7, 8, 9 & 10 Mm Od Fits Directly On 10 Mm Id Tube. For Medical Termination Of Pregnancy , Cannula, Nasal Oxygen Cannula { Set } , Twin Bore { Accessory For Compressed Air Breathing } All Size { Adult & Pediatric } , Soft And Kink Resistant Pvc , Cannula, Retrograde Cardiopledgia Cannula : Silicone Bodies And Autoinflate Cuff With Pressure Monitoring Lines . A Variety Of Cuffs With Stylets, Ce & Usfda Approved. , Cannula, Single Stage Venous Cannula, Malleable, Wire Reinforced Adult With Multiport And Different Types Of Tips , Cannula, Single Stage Venous Cannula, Malleable, Wire Reinforced Paediatric With Multiport And Different Types Of Tips , Cannula, Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated . Size 24G Suitable For Paediatric & Neonatal Use , Cannula, Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated . Size 26G Suitable For Paediatric & Neonatal Use , Cannula, Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 18G , Cannula, Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 20G , Cannula, Sterile Disposable ( Single Use ) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 22G , Cannula, Vessel Cannula : Clear Body, Soft Plastic Tip, Female Luer Lock. Size : 3 Mm Blunt Tip , Capd Catheter Tench Koff Curved 62Cm. , Capd Catheter Tench Koff Straigth 42Cm. , Cardiac Pacing Wire ( Electrode ) , Temporary, Sterile, Cir, Tapercut, 26 Mm Needle With Self Retaining System , Catheter Double Lumen Internal Jugular Curved / Straight 10Fr. , Catheter Double Lumen Internal Jugular Curved / Straight 8Fr. , Catheter Double Lumen Internal Jugular Curved / Straight11.5Fr. , Catheter Permanent / Tunnelled / Cuffed ( Paediatric ) , Catheter Permanent / Tunnelled / Cuffed 19Cm , Catheter Triple Lumen , Catheter, Aortic Balloon Valvoplasty Catheter , Catheter, Cardiac Catheter Introducer Sheath With Needle ( Femoral ) - 5F / 6F / 7F , Catheter, Disposable Thoracic Drainage System - Thoracic Drainage, Size 20Fr To 32Fr , Catheter, Double Lumen Femoral Catheter For Dialysis , Catheter, Fogarty Arterial Embolectomy Catheters Size 3Fr - 7Fr , Catheter, Foley Ballon 3 Way Catheter ( 22-30 F ) ( Cap. 30-50 Ml. ) , Catheter, Mitral Balloon Angioplasty Catheter , Catheter, Pulmonary Balloon Angioplasty Catheter , Catheter, Subclavian Catheter Introducer Set 45 Cm ( Plain ) , Catheter, Ureteric Catheter • Designed For Short Term Catheterization • E.T.O. Sterile And Pyrogen Free. • Assorted Sizes Like ( 10 / 12 / 14 Fg ) As Per Demand. , Catheter. Umbilical Catheter { For New Born } All Size, With Female Flexible Mount , Open Tip Should Be Soft, Rounded, Atraumatic , Length 40 Cm , Central Venous Catheter : 24G Radiopaque Polyurethane Peripherally Inserted Central Venous Catheter For Premature Neonates Weighing <1Kg , Central Venous Catheter : 28G Radiopaque Polyurethane Peripherally Inserted Central Venous Catheter For Premature Neonates Weighing <1Kg , Central Venus Line ( Triple Lumen Catheter Set ) Consists Of Guide Wire, Introducer Needle & Syringe, Dilator, Scalpel, Clamp, Suture Wing, Injection Port, Extension Line Clamps, Syringe & Needle. , Clips, Towel Holding, Cross Action , Closed Loop Suction Catheter : Closed Loop Suction Catheter Systems, Size: ( 6 Fr, 8Fr, 10Fr, 12Fr ) : Includes Protective Soft Sleeve To Completely Isolate Suction Catheter From Direct Contact To Caregivers And Usages, Life 48-72 Hours , Closed Loop Suction Catheter: Closed Loop Suction Catheter Systems, Size: ( 6Fr, 8Fr, 10Fr ) Includes Protective Soft Sleeve To Completely Isolate Suction Catheter From Direct Contact To Caregivers And Usage Life 48-72 Hours , Collagen Sheets 10 X 10Cm , Composite Light Weight Mesh Made Of Polypropylene And Polyglactin Size 9 Cm - 11 Cm X 14 Cm -16 Cm , Composite Light Weight Mesh Made Of Polypropylene And Polyglactin Size 14 Cm - 16 Cm X 14 Cm - 16 Cm , Composite Light Weight Mesh Made Of Polypropylene And Polyglactin Size 28 Cm - 32 Cm X 28 Cm - 32 Cm , Composite Light Weight Mesh Made Of Polypropylene And Polyglactin Size 5 Cm - 7 Cm X 10 Cm - 12 Cm , Coronary Angioplasty Guide Wire 0.014" Diameter, Hydrophilic Wire , Coronary Angioplasty Guide Wire ( Ptca Wire ) , Corrugated Drainage Sheet, Sterile, Multichannel, With Radio Opaque Line, Single Use - All Sizes , Cover Glass 0.16 To 0.19 Mm Thick, Rectangular, Sizes [ 25 Mm X 50 Mm ] , Cover Glass 0.16 To 0.19 Mm Thick, Square Of 5 Sizes [ 7 / 8" Or 4 / 5" Or 3 / 4" Or 11 / 4" Or 1½” ] , Cvc 4 Fr. With Anti Kinking Nitnol Guide Wire ( Paediatric ) - 20G / 23G / 23G , 6Cm / 8Cm / 10Cm * 4.5Fr. Thermosensitive Polyurethane Triple Lumen Paediatric Cvc. * It Has Anti Kinking Nitnol Guide Wire , Cvc 5.5 Fr. With Anti Kinking Nitnol Guide Wire ( Paediatric ) - 8 Cm / 12.5 Cm * 5.5Fr. Thermosensitive Polyurethane Triple Lumen Paediatric Cvc. * It Has Anti Kinking Nitnol Guide Wire , Cvc Single Lumen Catheter : 22 G / 24G Polyurethane Single Lumen 8 Cm Length. , Diagnostic Catheter, Amplatz –Left Size: 6F, 7F • Catheter Length Should Be 100 - 110Cm. , Diagnostic Catheter, Amplatz -Right Size: 6F, 7F • Catheter Length Should Be 100 - 110Cm. , Diagnostic Catheter, Size :- 4Fr., 5Fr., & 6Fr. • Shape Should Be Judkin Left. • Catheter Length Should Be 100 - 110Cm. , Diagnostic Catheter, Size :- 4Fr., 5Fr., & 6Fr. • Shape Should Be Judkin Right. • Curve 3.0, 3.5, 4.0, 4.5 & 5.0Cm. Catheter Length Should Be 100-110 Cm , Diagnostic Catheter, Size :- 6F & 7F . • Shape Should Be Amplatz Right -1 . • Catheter Length Should Be 90 - 110Cm. , Diagnostic Catheter, Size :- 6F & 7F . • Shape Should Be Amplatz Right -2 . • Catheter Length Should Be 90 - 110Cm. , Diagnostic Catheter, Size: 6Fr. • Shape Should Be Multipurpose. • Catheter Length Should Be 90 - 110Cm. , Diagnostic Glide Catheter For Abdominal Angiographiy Size: 5Fr & 6 Fr. • Should Be Hydrophilic Polymer Coated Catheter. • Should Be Soft Tip Is Installed On Distal End. • Should Be Available Different Shape Type. , Diagnostic Glide Catheter For Cerebral Angiographiy Size: 5Fr & 6 Fr. • Should Be Hydrophilic Polymer Coated Catheter. • Should Be Soft Tip Is Installed On Distal End. • Should Be Available Different Shape Type. , Disposable Blood Sample Collection Vial, Sugar Vial, Edta Vial, Heparin Coated Having Internal Vacuum With Colour Coded Caps ( Average Rate Is Required ) , Disposable Blood Sample Collection Vial, Sugar Vial, Edta Vial, Heparin Coated Non Vacuum With Colour Coded Caps ( Average Rate Is Required ) , Disposable Hme Filter : Disposable Hme Filter, Resistance To Flow ( Iso 9360 ) 30 Il / Min-0.8 Cm H2o , Disposable Hme Filter : Disposable Hme Filter, Resistance To Flow ( Iso 9360 ) 90 Il / Min-3.2 Cm H2o , Disposable Needles 18G , Disposable Needles 20G , Disposable Needles 22G , Disposable Needles 23G , Disposable Needles 24G , Disposable Needles 26G , Disposable Syringes With Needle ( Assorted Size ) Cgs 10 Cc , Disposable Syringes With Needle ( Assorted Size ) Cgs 2 Cc , Disposable Syringes With Needle ( Assorted Size ) Cgs 20 Cc , Disposable Syringes With Needle ( Assorted Size ) Cgs 5 Cc , Double Blood Bag ( 350 Ml ) Specifications :- 1. One Primary Bag ( Capacity: 350Ml ) & One Satellite Bag ( Capacity: 300Ml ) 2. Dehp / Totm Plastic, Sterile, Pyroxene Free, Closed Systems. 3. Filled With Clear 49Ml Cpda Solution For Primary Bag. 4. Transparent Container Completes With Flexible Nonkinking & Non-Sticking Collection Tube. 5. Impregnated With Unique Multiple Id / Segment Number. 6. The Needle Should Be Of 16 Gauges, Ultra-Thin Sharp, Bevelled Tip. 7. 2 Pairs Of Aluminium Metal Clip Should Accompany Each Bag. 8. The Specification Should Be As Per Iso Standard. 9. The Detail Of The Specification Is Made Available In The Tender Document And Naco Website. , Drape, Basic Surgical Drape: Back Table Cover, Top Drape, Bottom Drape, Side Drape, Reinforced Mayo’S Stand Cover, Suture Bag, Towel. , Drape, Cabg Drape: High Barrier Disposable Surgical Drapes Containing Hypoallergenic Acrylate Type Adhesive. Made Of Aami Level 4 Impervious Absorbent Material Throughout The Drape. Contents: 4 Self Adhesive Cautery Bags ( 30Cmx35cm ) , 3 Op Tapes ( 10Cmx55cm ) , 4 Lint Free Hand Towels ( 23.5Cmx38cm ) , 4 Self Adhesive Towel Drapes ( 91.5Cmx100cm ) , 1 Self Adhesive Medium Drape ( 183Cmx183cm ) , 1 Self Adhesive Large Drape ( 150Cmx250cm ) , 1 Instrument Table Drape ( 150Cmx200cm ) , 1 Large Instrument Table Drape ( 183Cmx240cm ) , 1 Self Adhesive Bilateral Split Drape ( 183Cmx200cm ) , 2 Triangular Drape ( 91.5Cmx91.5Cmx129cm , Drape, Disposable Drape For Craniotomy Prepackaged Sterile , Drape, Disposable Drape For Spinal Surgery Prepackaged Sterile , Drape, Sterile Surgical Drape : Antimicrobial Incise Drape. Size : Dimensions Are Approximate 56 Cm X 45 Cm , Ecg Paper ( Chemical Coated ) , Ecg Paper Computerised Triple Channel

Key Dates

Contract Date 13 Apr 2022

Contact Information

Company Name
Awarded Bids List
S.No Bid Number Bidder Name Awarded Currency Awarded Value
1 2334241 STANDARD ANALYTICAL LABORATORY ND PVT LTD INR 1.00
2 2335702 Delhi Test House INR 1.00
3 2335771 ITL LABS PVT. LTD INR 1.00
4 2336269 Multani Pharmaceuticals Ltd INR 1.00
Contract Value 1
Contract Date 13 Apr 2022

Complete details of the selected Tender
Organisation Name : Vijaya Bank
Organisation Type : Public Sector Banks Ministry : Ministry of Finance
Tender Ref. No : DIT/DELHIARMB/07052016/1
Tender Title : E-Auction Sale Notice for the properties of M/s Guru Kripa Iron Trading Pvt Ltd, mortgaged to Vijaya Bank and taken possession under the provisions of SARFAESI Act 2002.
Product Category : Land/Building
Sub Category :
Tender Value (INR if not mentioned):
Rs 1,62,00,000/-
EMD :
1620000
Document Cost :
0
Tender Type : Auction
Location : Delhi
First   
Announcement Date :
5-July-2016  
Publication Date on Portal: 5-July-2016 At : 8:03:09 PM  
Last Date of Document Collection :  
8-August-2016 Up To : 5:00 PM  
Last date for  
Submission :
8-August-2016 Up To : 5:00 PM  
Opening Date : 10-August-2016 At : 11:00 AM  
Work Description :
Pre-Qualification :
PreBid Meet Date : --
Tender Document : View Document *
Bid Document : Document Not available
Tech. Document : Document Not available
Sector : Banking, Finance & Insurance
State : Karnataka
 
For further Information Contact:
Name : Santhosh Aili
E-Mail : cbsprog11@vijayabank.co.in
Phone Office : 08025584066
Fax : 08025582747
Address :
City : Bangalore

  download Adobe® Reader®
Adobe® and Get Adobe® Reader® logo are trademarks or registered trademarks of Adobe Systems Inc. in the US and/or other countries.

View Notice Now...

Login with your Social Account for Instant Access to this notice


Tell us about your Product / Services,
We will Find Tenders for you