Contract Award Notice |
|
TRR | 4377283 |
Organization | Directorate Of Technical Education |
Tender No | GCE/DPI/001315/B1/EEE/24/2020 |
Funded By | Self-Funded |
Country | India , Southern Asia |
Contract Value | 767,000 |
Work Detail |
Purchase Of Equipments For Eee Department - Digital Multimeter With True Rmsand Indicatedistorted Waveform \ N• 6040 Counts With Bar Graph Display \ N• 600 Mv To 600 V Dc \ N• ±1.2 % ± 3Dgt Resolution \ N• 600?a Dc To 10 A Ac / Dc \ N• Resistance Measurement Upto 60 M? \ N• Capacitance 40 To 4000?f \ N• Frequency Up To 10 Mhz \ N• Duty Cycle0.1 - 99.9% ( Pulse Width / Pulse Period ) \ N• Iec 61010-1 Cat Iii \ N 2 Ac / Dc Clampmeter \ N• 1000A Ac / Dc Current Clamp \ N• 1.5%Rdg ± 5Dgt Resolution Current \ N• 600 V Ac / Dc Voltage True Rms \ N• 1.3%Rdg±5Dgt Resolution Voltage \ N• F40 Conductor Size \ N• Frequency 10 Khz Auto Range \ N• Duty Cycle0.1 - 99.9% \ N• Non Contact Voltage ( Ncv ) \ N• Min / Max Record \ N• Auto Power Save \ N• Iec 61010-1 Cat Iv 600 V \ N 3 High Sensitivity, Miniature Ac / Dc Clamp Meter \ N• 0.1Ma Minimum Resolution For Ac Current \ N• 1Ma Minimum Resolution For Dc Current. \ N• Ø7.5Mm Conductor Size \ N• 200Ma / 2 / 20A Ac \ N• 2 / 20A Dc \ N• ±1%Rdg±2Dgt Accuracy \ N• 3 1 / 2 Digit Lcd Display With Recorder \ N 4 1Kv Digital Insulation Tester \ N• Trac-Loc Function \ N• 250V, 500V, 1000V Ranges \ N• 200Ma Continuity Range \ N• Live Circuit Waring \ N• Illuminated Scale ( Bargraph Display ) \ N• Automatic Discharge \ N• Auto Null Function \ N• Min 1Ma On Current Insulation Tests As Per Iec 61557 5 Digital Earth Resistance Tester \ N• Measuring Range 2O To 200Ko \ N• Earth Resistivity Of 2O To 200Ko \ N• Auto Null Function To Automatically Subtract The Test Lead \ Nresistance Before Displaying The Real Continuity Resistance Value \ N• Measurement Method Earth Resistance: Fall-Of-Potential Method \ N ( Currents And Voltages Measured Via The Probes ) \ N• Measurement Method Of Earth Resistivity ( ? ) : Wenner 4-Pole Method \ N• Series Interference Voltage ( Earth Voltage ) \ N• Rms Rectifier ( Between The E-S Terminals ) \ N• Over Load Protection Between E-S ( P ) And Between E-H ( C ) \ Nterminals Ac280v / 10 Sec 6 Digital Light Meter \ N• Data Hold Function \ N• 0.1 - 19990Lux \ N• Angular Incident - \ N 30º Less Than ±3% \ N 60º Less Than ±10% \ N 80º Less Than ±30% \ N• Response Time 2.5Times / Sec 7 Phase Indicator \ N• Operating Voltage 110 - 600V Ac 1 \ N• Frequency Response 50 / 60Hz \ N• Withstand Voltage 5550V Ac For 1 Minute \ N• Iec 61010-1 Cat Iii 600V 8 Clamp On Earth Tester \ N• True Rms \ N• The Earth Resistance From 0.05 To 1500O Can Be Measured Without The Auxiliary Earth Spikes. \ N• Accurate True Rms Readings Of Ac Current Including Distorted Waveform From 1Ma To 30.0A \ N• Save And Display Up To 100 Measurement Data \ N• Earth Resistance Auto Range 20.00 / 200.0 / 1500O \ N• Sample Rate Approx. 1 Times Per Second \ N• Current Consumption Approx. 50Ma ( Max.100Ma ) \ N• Conductor Size Ø32mm \ N 9 5 Kv Insulation Tester \ N• 250V, 500V, 1000V, 2500V, 5000V Ranges \ N• Insulation Resistance Up To 10To \ N• Short-Circuit Current Up To 5Ma \ N• Diagnostic Insulation Tests: Ir, Pi, Dar, Dd, Sv, Ramp \ N ( Breakdown And Burn Modes ) , Capacitance, Leakage Current \ N• Wireless Communication By Bluetooth For Transferring And \ Nshowing Real-Time Data To Pc And Android Device \ N• Accuracy 0.1T - 9.99To , ±20%Rdg \ N• Capacitance Measurement 5.0Nf - 50.0?f, 5.0Nf - 25.0?f ( 5000V ) \ N• Current Measurement 0.00Na - 5.50Ma \ N• Voltage Measurement Ac: 30 - 600V ( 50 / 60Hz ) , Dc: ±30 - ±600V \ N |
Key Dates |
|
Contract Date | 03 Feb 2021 |
Contact Information |
||||||||||||||||||||||||||||||||||||||||
View Notice Now...Login with your Social Account for Instant Access to this notice
|